• :  
BM ENG
  • Home
  • Service
  • International Standard
  • FAQ
  • Publish
  • signin
  •  Cart ()
Search Malaysian Standard (MS)
 Advanced Search Search




Road vehicles - Elastomeric cups and seals for cylinders for hydraulic braking systems using a non-petroleum base hydraulic brake fluid (Service temperature 120 OC Max.) (ISO 4928:2006, IDT)
MS ISO 4928:2008 (CONFIRMED:2013)
Status : 1st Confirmation
Format : PDF

This Malaysian Standard specifies performance tests of brake cups and seals for hydraulic braking systems for road vehicles; it does not include requirements relating to chemical composition, tensile ....Read more strength and elongation of the rubber compound. Disc brake seals are not covered by this standard. This standard is applicable to moulded seals (cups or double-lipped type gland seals), 60 mm in diameter and smaller, compounded from high temperature-resistant rubber, for use in hydraulic actuating cylinders using road vehicle non-petroleum base hydraulic brake fluid. Close

RM 45.00

Document will be sent via email



 Add To Cart

Textiles - Seam types - Classification and terminology (ISO 4916:1991, IDT)
MS ISO 4916:2006 (CONFIRMED:2024)
Status : 2nd Confirmation
Format : PDF

This Malaysian Standard classifies, illustrates and designates, the various kinds of stitched seams. lt is not intended to be fully comprehensive but to illustrate a number of the most used seam types ....Read more . lt is applicable to seams used most particularly in the clothing industry. All illustrations show the cross-section of the material configuration only. 
This Malaysian Standard should be read in conjunction with ISO 4915.
Close

RM 105.00

Document will be sent via email



 Add To Cart

Textiles - stitch types - Classification and terminology (ISO 4915:1991, IDT)
MS ISO 4915:2006 (CONFIRMED:2024)
Status : 2nd Confirmation
Format : PDF

This Malaysian Standard classifies, designates, describes and illustrates the various kinds of stitch types used in hand-and machine-sewn seams.

RM 90.00

Document will be sent via email



 Add To Cart

INFORMATION TECHNOLOGY - DATA COMMUNICATION-370POLE DTE/DCE INTERFACE CONNECTOR ANDCONTACT NUMBER ASSIGNMENTS
MS ISO 4902:1989 (CONFIRMED:2007)
Status : 2nd Confirmation
Format : PDF

This Standard specifies the 37-pole connector andthe assignment of contact numbers at the interface betweendata terminal equipment (DTE) and data circuit-terminatingequipment (DCE) where CCITT ‘) Re ....Read more commendation V.24together with Recommendations V.10 and V.11 are applicable. Close

RM 45.00

Document will be sent via email



 Add To Cart

Plastics - Methods of exposure to laboratory light sources - Part 4: Open-flame carbon-arc lamps (First revision) (ISO 4892-4:2004, COR. 1:2005, IDT)
MS ISO 4892-4:2012
Status : 1st Revision
Format : PDF

This Malaysian Standard specifies methods for exposing specimens to open-flame carbon-arc lamps in the presence of moisture to reproduce the weathering effects that occur when materials are exposed in ....Read more actual end-use environments in daylight or daylight filtered through window glass. 
The specimens are exposed to filtered open-flame carbon-arc light under controlled environmental conditions (temperature, moisture). Various filters are described.

Specimen preparation and evaluation of the results are covered in other Malaysian Standard for specific materials.

General guidance is given in MS ISO 4892-1.
Close

RM 30.00

Document will be sent via email



 Add To Cart

Plastics - Methods of exposure to laboratory light sources - Part 3: Fluorescent UV lamps (First revision) (ISO 4892-3:2006, IDT)
MS ISO 4892-3:2012
Status : 1st Revision
Format : PDF

This Malaysian Standard specifies methods for exposing specimens to fluorescent UV radiation, heat and water in apparatus designed to reproduce the weathering effects that occur when materials are exp ....Read more osed in actual end-use environments to daylight, or to daylight through window glass. 
The specimens are exposed to fluorescent UV lamps under controlled environmental conditions (temperature, humidity and/or water). Different types of fluorescent UV lamp may be used to meet all the requirements for testing different materials.

Specimen preparation and evaluation of the results are covered in other ISO documents for specific materials.

General guidance is given in ISO 4892-1.

NOTE. Fluorescent UV lamp exposures for paints, varnishes and other coatings are described in ISO 11507[4].
Close

RM 30.00

Document will be sent via email



 Add To Cart

Plastics - Methods of exposure to laboratory light sources - Part 1: General guidance (First revision) (ISO 4892-1:1999, IDT)
MS ISO 4892-1:2012
Status : 1st Revision
Format : PDF

This part of Malaysian Standard provides information and general guidance relevant to the selection and operation of the methods of exposure described in detail in subsequent parts. 
It also de ....Read more scribes and recommends methods for determining irradiance and radiant exposure, and a black-standard/black-panel thermometer. Close

RM 30.00

Document will be sent via email



 Add To Cart

Plastics - Methods of exposure to laboratory light sources - Part 2: Xenon-arc lamps (First revision) (ISO 4892-2:2006, AMD. 1:2009, IDT)
MS ISO 4892-2:2012
Status : 1st Revision
Format : PDF

This Malaysian Standard specifies methods for exposing specimens to xenon-arc light in the presence of moisture to reproduce the weathering effects that occur when materials are exposed in actual end- ....Read more use environments in daylight or daylight filtered through window glass. 
The specimens are exposed to filtered xenon-arc light under controlled conditions (temperature, humidity and/or wetting). Various types of xenon-arc light source and various filter combinations may be used to meet different requirements.

Specimen preparation and evaluation of the results are covered in other International Standards for specific materials.

General guidance is given in ISO 4892-1.

NOTE: Xenon-arc exposures of paints and varnishes are described in ISO 11341.
Close

RM 30.00

Document will be sent via email



 Add To Cart

TOLERANCES FOR FASTENERS - PART 3: PLAIN WASHERS FOR BOLTS, SCEWS AND NUTS - PRODUCT GRADES A AND B (ISO 4759-3:2000, IDT)
MS ISO 4759-3:2006 (CONFIRMED:2011)
Status : Withdrawn
Format : PDF

This Malaysian Standard establishes a selection of tolerances for use in the preparation of ISO product standards for punched plain washers of product grades A and C, for use with bolts, screws and nu ....Read more ts of nominal thread diameters of from 1 mm to 150 mm inclusive. Close

NOT FOR SALE

"Please contact us if you are interested to purchase for reference."




IRON ORES AND DIRECT REDUCED IRON - DETERMINATION OF SIZE DISTRIBUTION BY SIEVING (FIRST REVISION) (ISO 4701:2008, IDT)
MS ISO 4701:2010
Status : 1st Revision
Format : PDF

This Malaysian Standard specifies the methods to be employed for determination of size distributions by sieving of iron ore and direct reduced iron (exclude briquetted iron), utilizing sieves having a ....Read more perture sizes of 36 ?m or larger. The size distribution is expressed in terms of mass and percentage mass, passed or retained on selected sieves. The purpose of this Malaysian Standard is to provide a basis for any testing of iron ore and direct reduced iron involving size determination for use by contracting parties in the sale and purchase of these materials. 
When this Malaysian Standard is used for comparative purposes, agreement should be reached between the concerned parties on selection of the detailed method to be employed in order to eliminate sources of subsequent controversy.
Close

RM 75.00

Document will be sent via email



 Add To Cart

  • ‹
  • 1
  • 2
  • ...
  • 244
  • 245
  • 246
  • 247
  • 248
  • 249
  • 250
  • ...
  • 587
  • 588
  • ›
©2020 All rights reserved
Department of Standards Malaysia (STANDARDS MALAYSIA). Best viewed on latest browser.