Search Malaysian Standard (MS)
 Advanced Search Search


ELECTRICITY METERING EQUIPMENT (a.c.) - PARTICULAR REQUIREMENTS - PART 23: STATIC METERS FOR REACTIVE ENERGY (CLASSES 2 AND 3) (SECOND REVISION) (IEC 62053-23:2003, MOD)
MS 62053-23:2009
Status : 2nd Revision
Format : PDF

This Malaysian Standard applies only to newly manufactured static var-hour meters of accuracy classes 2 and 3, for the measurement of alternating current electrical reactive energy in 50 Hz or 60 Hz n ....Read more etworks and it applies to their type tests only. For practical reasons, this standard is based on a conventional definition of reactive energy for sinusoidal currents and voltages containing the fundamental frequency only. 

It applies only to static var-hour meters for indoor and outdoor application consisting of a measuring element and register(s) enclosed together in a meter case. It also applies to operation indicator(s) and test output(s). If the meter has a measuring element for more than one type of energy (multi-energy meters), or when other functional elements, like maximum demand indicators, electronic tariff registers, time switches, ripple control receivers, datac ommunication interfaces, etc. are enclosed in the meter case, then the relevant standards for these elements also a
Close

RM 45.00

Document will be sent via email



 Add To Cart

ELECTRICITY METERING EQUIPMENT (a.c.) - PARTICULAR REQUIREMENTS - PART 61: POWER CONSUMPTION AND VOLTAGE REQUIREMENTS (SECOND REVISION) (IEC 62053-61:1998, MOD)
MS 62053-61:2009
Status : 2nd Revision
Format : PDF

This Malaysian Standard applies only to newly manufactured 'combined meters', measuring more than one type of electric energy (e.g. active and reactive) and meters integrating additional functions whi ....Read more ch are not in the scope of MS 62052-11, MS 62053-22, MS 62053-21 and MS 62053-23 standards; these additional functions, all related to electric energy metering are maximum demand indicator, time switches, ripple control or radio receivers, etc. 

When other devices and functions not related to electric energy metering and billing are enclosed in the same meter case (such as power line carrier devices, load curve recording devices, telephone and radio transceiver or network current and voltage measurement and analysis devices, etc.) this standard applies only to the energy metering and processing section. For all the meter characteristics and functions already described in existing standards, these standards will apply for the corresponding characteristics and functions.
Close

RM 15.00

Document will be sent via email



 Add To Cart

Electricity metering equipment (a.c.) - General requirements, tests and test conditions - Part 21: Tariff and load control equipment (Second revision) (IEC 62052-21:2004, MOD)
MS 62052-21:2009 (CONFIRMED:2015)
Status : 1st Confirmation
Format : PDF

This Malaysian Standard specifies general requirements for the type test of newly manufactured indoor tariff and load control equipment, like electronic ripple control receivers and time switches that ....Read more are used to control electrical loads, multi-tariff registers and maximum demand indicator devices. 

This standard gives no requirements for constructional details internal to the tariff and load control equipment.

In the case where tariff and load control functionality is integrated into multifunction electricity metering equipment, the relevant parts of this standard apply.

This standard does not cover the acceptance tests and the conformity tests. Nevertheless, an example of what could be an acceptance test is given in Annex F.

The dependability aspect is covered by the documents of the MS 62059 series.
Close

RM 75.00

Document will be sent via email



 Add To Cart

ELECTRICITY METERING EQUIPMENT (a.c.) - GENERAL REQUIREMENTS, TESTS AND TEST CONDITIONS - PART 11: METERING EQUIPMENT (SECOND REVISION) (IEC 62052-11:2003, MOD)
MS 62052-11:2009
Status : 2nd Revision
Format : PDF

This Malaysian Standard covers type tests for electricity metering equipment for indoor and outdoor application and to newly manufactured equipment designed to measure the electric energy on 50 Hz or ....Read more 60 Hz networks, with a voltage up to 600 V. 
It applies to electromechanical or static meters for indoor and outdoor application consisting of a measuring element and register(s) enclosed together in a meter case. It also applies to operation indicator(s) and test output(s). If the meter has a measuring element for more than one type of energy (multi-energy meters), or when other functional elements, such as maximum demand indicators, electronic tariff registers, time switches, ripple control receivers, data communication interfaces, etc. are enclosed in the meter case, then the relevant standards for these elements apply.

It does not apply to:
a) portable meters;
b) data interfaces to the register of the meter; and
c) reference meters.
For rack-mounted meters, the mechanical propert
Close

RM 75.00

Document will be sent via email



 Add To Cart

Uninterruptible power systems (UPS) - Part 1: General and safety requirements for UPS (First revision) (IEC 62040-1:2008, IDT)
MS IEC 62040-1:2012
Status : 1st Revision
Format : PDF

This Malaysia Standard applies to uninterruptible power systems (UPS) with an electrical energy storage device in the d.c. link. It is used with IEC 60950-1, which is referred to in this standard as " ....Read more RD" (reference document). Close

RM 105.00

Document will be sent via email



 Add To Cart

Uninterruptible power systems (UPS) - Part 3: Method of specifying the performance and test requirements (IEC 62040-3:1999, IDT)
MS IEC 62040-3:2012
Status : Original
Format : PDF

This Malaysian Standard applies to electronic indirect a.c. converter systems with electrical energy storage means in the d.c. link. The primary function of the uninterruptible power system (UPS) cove ....Read more red by this standard is to ensure continuity of an alternating power source. The uninterruptible power system may also serve to improve the quality of the power source by keeping it within specified characteristics. Close

RM 165.00

Document will be sent via email



 Add To Cart

DISCHARGE LAMPS (EXCLUDING FLUORESCENT LAMPS) - SAFETY SPECIFICATIONS (IEC 62035:2003, IDT)
MS IEC 62035:2011
Status : Original
Format : PDF

This Malaysian Standard specifies the safety requirements for discharge lamps (excluding fluorescent lamps) for general lighting purposes. This standard is applicable to low-pressure sodium vapour lam ....Read more ps and to high-intensity discharge (HID) lamps, i.e. high-pressure mercury vapour lamps (including blended lamps), high-pressure sodium vapour lamps and metal halide lamps. It applies to single- and double-capped lamps. Close

RM 60.00

Document will be sent via email



 Add To Cart

LED MODULES FOR GENERAL LIGHTING - SAFETY SPECIFICATIONS (IEC 62031:2008, IDT)
MS IEC 62031:2011
Status : Original
Format : PDF

This Malaysian Standard specifies general and safety requirements for light-emitting diode (LED) modules: - LED modules without integral control gear for operation under constant voltage, constant cur ....Read more rent or constant power; - self-ballasted LED modules for use on d.c. supplies up to 250 V or a.c. supplies up to 1 000 V at 50 Hz or 60 Hz. Close

RM 30.00

Document will be sent via email



 Add To Cart

Insulating liquids - Determination of acidity - Part 1: Automatic potentiometric titration (IEC 62021-1:2003, IDT)
MS IEC 62021-1:2012
Status : Original
Format : PDF

This Malaysian Standard describes the procedure for the determination of the acidity of unused and used electrical mineral insulating oils.

RM 30.00

Document will be sent via email



 Add To Cart

Electrical accessories - Circuit-breakers and similar equipment for household use - Auxiliary contacts units (IEC 62019:2003, IDT)
MS IEC 62019:2007 (CONFIRMED:2013)
Status : 1st Confirmation
Format : PDF

This Malaysian Standard applies to auxiliary contact units associated (or intended to be associated) with circuit-breakers for overcurrent protection, and with residual current operated circuit-breake ....Read more rs with or without integral overcurrent protection for household and similar installations, having a rated voltage not exceeding 440 V a.c. and 250 V d.c., and a rated current not exceeding 10 A. Close