High-voltage switchgear and controlgear - Part 209: Cable connections for gas-insulated metal-enclosed switchgear for rated voltages above 52 kV - Fluid-filled and extruded insulation cables - Fluid-filled and dry-type cable-terminations (IEC 62271-209:2007, IDT)
MS IEC 62271-209:2008 (CONFIRMED:2015)
Status : 1st Confirmation
Format : PDF

This Malaysian Standard covers the connection assembly of fluid-filled and extruded cables to gas insulated metal enclosed switchgear (GIS), in single- or three-phase arrangements where the cable-term ....Read more inations are fluid-filled or dry type and there is a separating insulating barrier between the cable insulation and the gas insulation of the switchgear. Close

RM 30.00

Document will be sent via email



 Add To Cart

High-voltage switchgear and controlgear - Part 105: Alternating current switch-fuse combinations for rated voltages above 1 kV up to and including 52 kV (First revision) (IEC 62271-105:2012, IDT)
MS IEC 62271-105:2017
Status : 1st Revision
Format : PDF

This Malaysian Standard applies to three-pole units for public and industrial distribution systems which are functional assemblies of switches including switch-disconnectors and current limiting fuse ....Read more s designed so as to be capable of:

- breaking, at the rated recovery voltage, any current up to and including the rated shortcircuit breaking current;
- making, at the rated voltage, circuits to which the rated shortcircuit
breaking current applies.

It does not apply to fuse-circuit-breakers, fuse-contactors, combinations for motor-circuits or to combinations incorporating single capacitor bank switches.
Close

RM 90.00

Document will be sent via email



 Add To Cart

HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR – PART 105: ALTERNATING CURRENT SWITCH-FUSE COMBINATIONS (IEC 62271-105:2002, IDT)
MS IEC 62271-105:2006
Status : Withdrawal with replacement
Format : PDF

This Malaysian Standard applies to three-pole units for public and industrial distribution systems which are functional assemblies of switches including switch-disconnectors and current limiting fuses ....Read more designed so as to be capable of 

– breaking, at the rated recovery voltage, any current up to and including the rated shortcircuit breaking current,

– making, at the rated voltage, circuits to which the rated short-circuit breaking current
applies.

It does not apply to fuse-circuit-breakers, fuse-contactors, combinations for motor-circuits or to combinations incorporating single capacitor bank switches.
Close

NOT FOR SALE

"Please contact us if you are interested to purchase for reference."




HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 1: COMMON SPECIFICATIONS (FIRST REVISION) (IEC 62271-1:2007, IDT)
MS IEC 62271-1:2009
Status : 1st Revision
Format : PDF

This Malaysian Standard specifies a.c. switchgear and controlgear designed for indoor and outdoor installation and for operation at service frequencies up to and including 60 Hz on systems having volt ....Read more ages above 1 kV. This standard applies to all high-voltage switchgear and controlgear. Close

RM 195.00

Document will be sent via email



 Add To Cart

HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 203: GAS-INSULATED METAL-ENCLOSED SWITCHGEAR FOR RATED VOLTAGE ABOVE 52 KV (IEC 62271-203:2003, IDT)
MS IEC 62271-203:2007
Status : Withdrawal with replacement
Format : PDF

This Malaysian Standard standard specifies requirements for gas-insulated, metal-enclosed switchgear in which the insulation is obtained, at least partly, by an insulating gas other than air at atmosp ....Read more heric pressure, for alternating current of rated voltages above 52 kV, for indoor and outdoor installation, and for service frequencies up to and including 60 Hz. Close

NOT FOR SALE

"Please contact us if you are interested to purchase for reference."




HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR – PART 200: AC METAL-ENCLOSED SWITCHGEAR AND CONTROLGEAR FOR RATED VOLTAGES ABOVE 1 kV AND UP TO AND INCLUDING 52 kV (IEC 62271-200:2003, IDT)
MS IEC 62271-200:2005
Status : Withdrawal with replacement
Format : PDF

This Malaysian Standard specifies the requirments for factory-assembled metal-enclosed switchgear and controlgear for alternating current of rated voltages above 1 kV and up to and including 52 kV for ....Read more indoor and outdoor installation. It also applies for service frequencies up to and including 60 Hz. Enclosures may include fixed and removable components and may be filled with fluid (liquid or gas) to provide insulation. Close

NOT FOR SALE

"Please contact us if you are interested to purchase for reference."




HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 102: ALTERNATING CURRENT DISCONNECTORS AND EARTING SWITCHES (IEC 62271-102: 2001, IDT)
MS IEC 62271-102:2007
Status : Original
Format : PDF

This Malaysian Standard applies to alternating current disconnectors and earthing switches, designed for indoor and outdoor enclosed and open terminal installations for voltages above 1 000 V and for ....Read more service frequencies up to and including 60 Hz. Close

RM 135.00

Document will be sent via email



 Add To Cart

High-voltage switchgear and controlgear - Part 200: AC metal-enclosed switchgear and controlgear for rated voltages above 1 kV and up to and including 52 kV (First revision) (IEC 62271-200:2011, IDT)
MS IEC 62271-200:2017
Status : 1st Revision
Format : PDF

This Malaysian Standard specifies requirements for prefabricated metal enclosed switchgear and controlgear for alternating current of rated voltages above 1 kV and up to and including 52 kV for indoo ....Read more r and outdoor installation, and for service frequencies up to and including 60 Hz. Enclosures may include fixed and removable components and may be filled with fluid (liquid or gas) to provide insulation. Close

RM 135.00

Document will be sent via email



 Add To Cart

High-voltage switchgear and controlgear - Part 100: Alternating current circuit-breakers (First revision) (IEC 62271-100:2008, AMD. 1:2012, IDT)
MS IEC 62271-100:2017
Status : 1st Revision
Format : PDF

This Malaysian Standard is applicable to a.c. circuit-breakers designed for indoor or outdoor installation and for operation at frequencies of 50 Hz and 60 Hz on systems having voltages above 1 000 V. ....Read more It is only applicable to three-pole circuit-breakers for use in three-phase systems and single-pole circuit-breakers for use in single-phase systems. Close

RM 555.00

Document will be sent via email



 Add To Cart

High-voltage switchgear and controlgear - Part 203: Gas-insulated metal-enclosed switchgear for rated voltages above 52 kV (First revision) (IEC 62271-203:2011, IDT)
MS IEC 62271-203:2017
Status : 1st Revision
Format : PDF

This Malaysian Standard specifies requirements for gas-insulated metal-enclosed switchgear in which the insulation is obtained, at least partly, by an insulating gas other than air at atmospheric pres ....Read more sure, for alternating current of rated voltages above 52 kV, for indoor and outdoor installation, and for service frequencies up to and including 60 Hz. Close

RM 120.00

Document will be sent via email