• :  
BM ENG
  • Subscription
  • MS Catalogue
  • MS Pack
  • Purchase History
  • Cart
  • Hi
    !
    • My Profile
    • Portal
    • Log Out

Modal title

Widget settings form goes here

Search Malaysian Standard (MS)
 Advanced Search Search


Luminaires – Part 2-22: Particular requirements – Luminaires for emergency lighting (IEC 60598-2-22:2021, MOD)
MS 619-2-22:2025
Status : Original
Format : PDF

This part of IEC 60598 specifies requirements for emergency luminaires for use with electrical lamps on emergency power supplies not exceeding 1 000 V.

This document does not cover the ....Read more effects of non-emergency voltage reductions on luminaires incorporating high pressure discharge lamps.

This document gives general requirements for emergency lighting equipment.

In this document, the term "lamp" which also includes "light source(s)" where appropriate, is used.
Close

RM 75.00

Document will be sent via email



 Add To Cart

Conductors for overhead lines – Aluminium and aluminium alloy wires for concentric lay stranded conductors (IEC 62641:2022, IDT)
MS IEC 62641:2022
Status : Original
Format : PDF

This document specifies the mechanical and electrical properties of round and formed wires for equivalent diameters up to the values according to Table 3 for aluminium and aluminium alloys and accordi ....Read more ng to Table 4 for thermal resistant alloys. This document is applicable to aluminium and aluminium alloy wires for the manufacture of concentric lay overhead electrical stranded conductors with or without gap(s) for power transmission purposes.

The various materials and their designations are listed in Table 1. For calculation purposes, the values listed in Table 1 are used.
Close

RM 45.00

Document will be sent via email



 Add To Cart

Power cables with extruded insulation and their accessories for rated voltages from 1 kV (Um = 1,2 kV) up to 30 kV (Um = 36 kV) – Part 2: Cables for rated voltages from 6 kV (Um = 7,2 kV) up to 30 kV (Um = 36 kV) (IEC 60502-2:2014, IDT)
MS IEC 60502-2:2014
Status : Original
Format : PDF

This part of IEC 60502 specifies the construction, dimensions and test requirements of power cables with extruded solid insulation from 6 kV up to 30 kV for fixed installations such as distribution ne ....Read more tworks or industrial installations.

When determining applications, it is recommended that the possible risk of radial water ingress is considered. Cable designs with barriers claimed to prevent longitudinal water penetration and an associated test are included in this part of IEC 60502.

Cables for special installation and service conditions are not included, for example cables for overhead networks, the mining industry, nuclear power plants (in and around the containment area) nor for submarine use or shipboard application.
Close

RM 150.00

Document will be sent via email



 Add To Cart

Light electric vehicle battery swapping - Part 1: General guidelines
MS 2776-1:2025
Status : Original
Format : PDF

This document establishes a general overview and guidelines of swappable battery system (SBS) that applies to motor vehicle L category as classified in accordance with MS 1822 which referred as light ....Read more electric vehicle (LEV).

This document is not applicable to:

a) aspects related to maintenance and service of the battery swapping station (BSS);
b) vehicles designed primarily for use off-road; and
c) maintenance and service of LEV.
Close

RM 30.00

Document will be sent via email



 Add To Cart

Light electric vehicle battery swapping - Part 2: Safety requirements
MS 2776-2:2025
Status : Original
Format : PDF

This document provides safety requirements in a battery swapping system (BSSys), for the
purposes of swapping swappable battery system (SBS) of light electric vehicles (LEVs). The BSSys is inte ....Read more nded to be connected to the supply network. The supply voltage is in accordance with IEC 60038.

This standard also applies to BSSys supplied from on-site storage systems (e.g. buffer
batteries) and for LEV equipped with one (1) or more SBS. Aspects covered in this standard
includes:

a) safety requirements of the BSSys and/or its systems;
b) security requirements for communication;
c) electromagnetic compatibility (EMC);
d) signs and instructions; and
e) protection against electric shock and other hazards.

This document is not applicable to:

a) aspects related to maintenance and service of the battery swapping station (BSS);
b) trolley buses, rail vehicles and vehicles designed primarily for use off-road; and
c) maintenance and service of LEVs.
Close

RM 45.00

Document will be sent via email



 Add To Cart

Tenunan Malaysia – Bahagian 1: Songket Malaysia - Spesifikasi (Semakan ketiga)
MS 1747-1:2025 (BM)
Status : 3rd Revision
Format : PDF

Dokumen ini menetapkan spesifikasi bahan mentah yang digunakan dalam proses tenunan, kriteria kualiti, proses penghasilan, struktur asas, kaedah penjagaan, kaedah ujian, penandaan, dan pelabelan bagi ....Read more Songket Malaysia. Close

RM 60.00

Document will be sent via email



 Add To Cart

Sharing economy - Part 2: General trustworthiness and safety requirements for digital platforms
MS 2754-2:2024
Status : Original
Format : PDF

This document specifies general trustworthiness and safety requirements as well as provide guideline for platform operator when verifying providers, including on-boarding, maintenance and deactivation ....Read more .

This document applies to both digital platform operators and providers within the sharing economy. While this document does not cover system requirements for digital platforms, the document is still beneficial for system development.
Close

RM 60.00

Document will be sent via email



 Add To Cart

Innovation management system - Requirements (ISO 56001:2024, IDT)
MS ISO 56001:2024
Status : Original
Format : PDF

This document specifies requirements for an innovation management system that an organization can use to develop and demonstrate its innovation capability, enhance its innovation performance, and real ....Read more ize value for users, customers and other interested parties. The requirements in this document are generic.

This document is applicable to any organization, regardless of type or size, products and services provided, or the types of innovations and innovation approaches used.
Close

RM 60.00

Document will be sent via email



 Add To Cart

Fluids for electrotechnical applications - Mineral insulating oils for electrical equipment (IEC 60296:2020, MOD)
MS 60296:2024
Status : Original
Format : PDF

This document provides specifications and test methods for unused and recycled mineral insulating oils (see Clause 3 for definitions). It applies to mineral oil delivered according to the contractual ....Read more agreement, intended for use in transformers, switchgear and similar electrical equipment in which oil is required for insulation and heat transfer. Both unused oil and recycled oil under the scope of this document have not been used in, nor been in contact with electrical equipment or other equipment not required for manufacture, storage or transport.

Unused oils are obtained by refining, modifying and/or blending of petroleum products and other hydrocarbons from virgin feedstock.

Recycled oils are produced from oils previously used as mineral insulating oils in electrical equipment that have been subjected to re-refining or reclaiming (regeneration) by processes employed offsite. Such oils will have originally been supplied in compliance with a recognized unused mineral insulating oil specification. This document does not differentiate between the methods used to recycle mineral insulating oil. Oils treated on-site (see IEC 60422) are not within the scope of this document.

Oils with and without additives are both within the scope of this document.

This document does not apply to mineral insulating oils used as impregnating medium in cables or capacitors.
Close

RM 75.00

Document will be sent via email



 Add To Cart

Method of sampling insulating liquids (IEC 60475:2022 CMV, MOD)
MS 60475:2024
Status : Original
Format : PDF

This document is applicable to the sampling procedure used for insulating liquids in delivery containers and in electrical equipment such as power and instrument transformers, reactors, bushings, oil- ....Read more filled cables, oil-filled tank-type capacitors, switchgear and load tap changers (LTCs).

This document applies to liquids the viscosity of which at the sampling temperature is less than 1 500 mm2/s (or cSt). It applies to mineral oils and non-mineral oils (such as synthetic esters, natural esters, vegetable oils or silicones).

NOTE The oil viscosity at Sampling Lower Temperature is not applicable to operation in Malaysian climatic condition.
Close

RM 60.00

Document will be sent via email



 Add To Cart

  • ‹
  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • ...
  • 581
  • 582
  • ›