Specification for fire resistant doorsets - Part 9: Requirements and method of determining the performance of door coordinator devices
MS 1601-9:2007 (CONFIRMED:2015)
Status : 1st Confirmation
Format : PDF

This Malaysian Standard specifies requirements for door coordinator devices for double leaf swing doors fitted with door closers, and includes both separately mounted devices and mechanisms in corpora ....Read more ted in door closers. Door coordinator devices are used where it is necessary to ensure the correct sequence of closing of double leaf swing doors, for example doors with rebated meeting stiles.

Door coordinator devices manufactured in accordance with this Malaysian Standard shall be use as a requirement for reliable sequential closing of double leaf swing fire/smoke doors incorporating rebated meeting stiles to maintain the integrity of the doors.
Close

RM 45.00

Document will be sent via email



 Add To Cart

Specification for fire resistant doorsets - Part 6: Requirements and method of determining the performance of controlled door closing devices
MS 1601-6:2007 (CONFIRMED:2015)
Status : 1st Confirmation
Format : PDF

This Malaysian Standard specifies requirements for controlled door closing devices for swing doors, such devices being mounted on or in the frame, on or in the door, or in the floor.

Thi ....Read more s standard is limited to manually operated doors closing devices where the energy for closing is generated by the user upon opening the door, such that when the door is released, it returns to a closed position, in a controlled manner. Devices such as spring hinges, which do not exert a checking control during door closing, are outside the scope of this standard. Door closing devices (door closers) manufactured in accordance with this standard shall be used for reliable closing control of a door.

Door closers incorporating electrically powered hold-open mechanisms, are covered by EN 1155.
Close

RM 45.00

Document will be sent via email



 Add To Cart

Specification for fire resistant doorsets - Part 1: Design requirements and variation from the tested specimen
MS 1601-1:2009 (CONFIRMED:2015)
Status : 1st Confirmation
Format : PDF

This Malaysian Standard specifies requirements for the construction of fire resistant doorsets used to protect openings in walls and partitions which are required to resist the passage of fire.
....Read more
This standard also applies to transom panels over doors, where the panels are contained within the doorframe and form part of the fire resistant doorsets. This standard does not apply to lift-landing doors.
Close

RM 45.00

Document will be sent via email



 Add To Cart

Fire resistance tests - Part 7: Loadbearing elements - Walls
MS 1600-7:2012
Status : Original
Format : PDF

This Malaysian Standard specifies a method of testing the fire resistance of load bearing walls. It is applicable to both internal and external walls. The fire resistance of external walls can be dete ....Read more rmined under internal or external exposure conditions.

The fire resistance performance of load bearing walls is normally evaluated without perforations such as glazing. If it can be demonstrated that the design of the opening is such that load is not transmitted to the perforation, then the perforation need not be tested in the loaded condition.
Close

RM 45.00

Document will be sent via email



 Add To Cart

Fire resistance tests - Part 3: Non-loadbearing elements - Walls
MS 1600-3:2012
Status : Original
Format : PDF

This Malaysian Standard specifies a method for determining the fire resistance of non-loadbearing walls.

It is applicable to internal non-loadbearing walls with and without glazing, non- ....Read more loadbearing walls consisting almost wholly of glazing, (glazed non-loadbearing walls) and other non-loadbearing internal and external non-loadbearing walls with and without glazing. Close

RM 60.00

Document will be sent via email



 Add To Cart

Fire resistance tests - Part 2: Alternative and additional procedures
MS 1600-2:2012
Status : Original
Format : PDF

This Malaysian Standard specifies alternative heating conditions and other procedures that may need to be adopted under special circumstances.

Details of the alternative hydrocarbon, slo ....Read more w heating and external fire exposure heating curves and the additional impact test and measurement of radiation procedures are included within this standard. Within the appropriate clause for each procedure is given an explanation as to why it may necessary. Close

RM 30.00

Document will be sent via email



 Add To Cart

Fire resistance tests - Part 12: Service installations - Ducts
MS 1600-12:2012
Status : Original
Format : PDF

This Malaysian Standard specifies a method for determining the fire resistance of vertical and horizontal ventilation ducts under standardised fire conditions. The test examines the behaviour of ducts ....Read more exposed to fire from the outside (duct A) and fire inside the duct (duct B). Close

RM 60.00

Document will be sent via email



 Add To Cart

Fire resistance tests - Part 1: General requirements
MS 1600-1:2013
Status : Original
Format : PDF

This Malaysian Standard specifies the general principles for determining the fire resistence of various elements of construction when subjected to standard fire exposure conditions. Alternative and ad ....Read more ditional procedures to meet special requirements are given in EN 1363-2. Close

RM 90.00

Document will be sent via email



 Add To Cart

Household and similar electrical appliances - Safety - Part 2-5: Particular requirements for dishwashers (First revision) (IEC 60335-2-5: 2008, MOD)
MS 1597-2-5:2014
Status : 1st Revision
Format : PDF

This Malaysian Standard deals deals with the safety of electric dishwashers for household and similar purposes that are intended for washing and rinsing dishes, cutlery and other utensils, their rated ....Read more voltage being not more than 250 V for single-phase appliances and 480 V for other appliances.

Appliances intended for normal household and similar use and that may also be used by laymen in shops, in light industry and on farms, are within the scope of this standard. However, if the appliance is intended to be used professionally for washing and rinsing dishes and cutlery and other utensils that are used for commercial purposes, the appliance is not considered to be for household and similar use only.
Close

RM 30.00

Document will be sent via email



 Add To Cart

Household and similar electrical appliances - Safety - Part 2-3: Particular requirements for electric irons (Second revision) (IEC 60335-2-3:2012, MOD)
MS 1597-2-3:2017
Status : Original
Format : PDF

This Malaysian Standard deals with the safety of electric dry irons and steam irons, including those with a separate water reservoir or boiler having a capacity not exceeding 5 l, for household and si ....Read more milar purposes, their rated voltage being not more than 250 V.

Appliances not intended for normal household use, but which nevertheless may be a source of danger to the public, such as appliances intended to be used by laymen in shops, in light industry and on farms, are within the scope of this standard.
Close

RM 30.00

Document will be sent via email



 Add To Cart

  • ‹