Gaseous fire-extinguishing systems - physical properties and system design - Part 1: General requirements (First revision) (ISO 14520-1:2006, MOD)
MS 1746-1:2008 (CONFIRMED:2015)
Status : 1st Confirmation
Format : PDF

This Malaysian Standard specifies requirements and gives recommendations for the design, installation, testing, maintenance and safety of gaseous fire fighting systems in buildings, plant or other str ....Read more uctures, and the characteristics of the various extinguishants and types of fire for which they are a suitable extinguishing medium. 
It covers total flooding systems primarily related to buildings, plant and other specific applications, utilizing electrically non-conducting gaseous fire extinguishants that do not leave a residue after discharge and for which there are sufficient data currently available to enable validation of performance and safety characteristics by an appropriate independent authority. This Malaysian Standard is not applicable to explosion suppression.

This Malaysian Standard is not intended to indicate approval of the extinguishants listed therein by the appropriate authorities, as other extinguishants may be equally acceptable. CO2 is not included as it is covered
Close

RM 150.00

Document will be sent via email



 Add To Cart

GASEOUS FIRE-EXTINGUISHING SYSTEMS - PHYSICAL PROPERTIES AND SYSTEM DESIGN - PART 13: IG-100 EXTINGUISHANT (FIRST REVISION) (ISO 14520-13:2005, IDT)
MS 1746: PART 13:2008
Status : Withdrawal with replacement
Format : PDF

This Malaysian Standard gives specific requirements for gaseous fire-extinguishing systems, with respect to the IG-100 extinguishant. It includes details of physical properties, specification, usage a ....Read more nd safety aspects and is applicable to systems operating at nominal pressures of 200 bar and 300 bar, both at 15 deg C. This does not preclude the use of other systems; however, design data for other pressures were not available at time of publication. Close

NOT FOR SALE

"Please contact us if you are interested to purchase for reference."




GASEOUS FIRE-EXTINGUISHING SYSTEMS - PHYSICAL PROPERTIES AND SYSTEM DESIGN - PART 15: IG-541 EXTINGUISHANT (FIRST REVISION) (ISO 14520-15:2005, IDT)
MS 1746: PART 15:2008
Status : Withdrawal with replacement
Format : PDF

This Malaysian Standard specifies the requirements for gaseous fire-extinguishing systems, with respect to the IG-541 extinguishant. It includes details of physical properties, specification, usage an ....Read more d safety aspects and is applicable to systems operating at nominal pressures of 150 bar, 200 bar and 300 bar, at 15 deg C. This does not preclude the use of other systems; however, design data for other pressures were not available at time of publication. Close

NOT FOR SALE

"Please contact us if you are interested to purchase for reference."




GASEOUS FIRE-EXTINGUISHING SYSTEMS - PHYSICAL PROPERTIES AND SYSTEM DESIGN - PART 14: IG-55 EXTINGUISHANT (FIRST REVISION) (ISO 14520-14:2005, IDT)
MS 1746: PART 14:2008
Status : Withdrawal with replacement
Format : PDF

This Malaysian Standard specifies the requirements for gaseous fire-extinguishing systems, with respect to the IG-55 extinguishant. It includes details of physical properties, specification, usage and ....Read more safety aspects and is applicable to systems operating at nominal pressures of 150 bar, 200 bar and 300 bar, at 15 deg C. This does not preclude the use of other systems; however, design data for other pressures were not available at time of publication. Close

NOT FOR SALE

"Please contact us if you are interested to purchase for reference."




GASEOUS FIRE-EXTINGUISHING SYSTEMS - PHYSICAL PROPERTIES AND SYSTEM DESIGN - PART 12: IG-01 EXTINGUISHANT (FIRST REVISION) (ISO 14520-12:2005, IDT)
MS 1746: PART 12:2008
Status : Withdrawal with replacement
Format : PDF

This Malaysian Standard gives specific requirements for gaseous fire-extinguishing systems, with respect to the IG-01 extinguishant. It includes details of physical properties, specification, usage an ....Read more d safety aspects and is applicable to systems operating at nominal pressures of 160 bar, 200 bar and 300 bar at 15 deg C. This does not preclude the use of other systems; however, design data for other pressures were not available at time of publication. Close

NOT FOR SALE

"Please contact us if you are interested to purchase for reference."




Gaseous fire-extinguishing systems - Physical properties and system design - Part 11: HFC 236FA extinguishant (First revision) (ISO 14520-11:2005, IDT)
MS 1746-11:2008 (CONFIRMED:2015)
Status : 1st Confirmation
Format : PDF

This Malaysian Standard gives specific requirements for gaseous fire-extinguishing systems, with respect to the HFC 236fa extinguishant. It includes details of physical properties, specification, usag ....Read more e and safety aspects and is applicable to systems operating at nominal pressures of 25 bar and 42 bar superpressurized with nitrogen. This does not preclude the use of other systems. Close

RM 30.00

Document will be sent via email



 Add To Cart

Gaseous fire-extinguishing systems - Physical properties and system design - Part 10: HFC 23 extinguishant (First revision) (ISO 14520-10:2005, IDT)
MS 1746-10:2008 (CONFIRMED:2015)
Status : 1st Confirmation
Format : PDF

This Malaysian Standard specific requirements for gaseous fire-extinguishing systems, with respect to the HFC 23 extinguishant. It includes details of physical properties, specification, usage and saf ....Read more ety aspects and is applicable to systems operating at a nominal pressure of 41 bar without nitrogen superpressurization. This does not preclude the use of other systems. Close

RM 30.00

Document will be sent via email



 Add To Cart

Gaseous fire-extinguishing systems - Physical properties and system design - Part 9: HFC 227EA extinguishant (First revision) (ISO 14520-9:2006, IDT)
MS 1746-9:2008 (CONFIRMED:2015)
Status : 1st Confirmation
Format : PDF

This Malaysian Standard specifies requirements for gaseous fire-extinguishing systems, with respect to the HFC 227ea extinguishant. It includes details of physical properties, specification, usage and ....Read more safety aspects and is applicable to systems operating at nominal pressures of 25 bar and 42 bar superpressurized with nitrogen. This does not preclude the use of other systems. Close

RM 30.00

Document will be sent via email



 Add To Cart

Fire detection and fire alarm systems - Part 10: Flame detectors - Point detectors
MS 1745-10:2005 (CONFIRMED:2015)
Status : 1st Confirmation
Format : PDF

This Malaysian Standard specifies requirements, test methods and performance criteria for point-type, reset table flame detectors that operate using radiation from a flame for use in fire detection sy ....Read more stems installed in buildings. This standard does not cover flame detectors working on different principles from those described in this standard (although the standard may be used as guidance in assessing such products). Close

RM 75.00

Document will be sent via email



 Add To Cart

Fire detection and fire alarm systems - Part 5: Heat detectors - Point detectors
MS 1745-5:2005 (CONFIRMED:2015)
Status : 1st Confirmation
Format : PDF

This Malaysian Standard specifies the requirements, test methods and performance criteria for point heat detectors for use in fire detection and fire alarm systems for buildings. 
For other typ ....Read more es of heat detector, or for detectors intended for use in other environments, this standard should only be used for guidance. Heat detectors with special characteristics and developed for specific risks are not covered by this standard. Close

RM 90.00

Document will be sent via email



 Add To Cart

  • ‹