• :  
BM ENG
  • Subscription
  • MS Catalogue
  • MS Pack
  • Purchase History
  • Cart
  • Hi
    !
    • My Profile
    • Portal
    • Log Out

Modal title

Widget settings form goes here

Search Malaysian Standard (MS)
 Advanced Search Search


EXPLOSIVE ATMOSPHERES - PART 29-1: GAS DETECTORS - PERFORMANCE REQUIREMENTS OF DETECTORS FOR FLAMMABLE GASES (IEC 60079-29-1:2007, IDT)
MS IEC 60079-29-1:2009
Status : Original
Format : PDF

This Malaysian Standard specifies general requirements for construction, testing and performance, and describes the test methods that apply to portable, transportable and fixed apparatus for the detec ....Read more tion and measurement of flammable gas or vapour concentrations with air. This Malaysian Standard is also applicable when an apparatus manufacturer makes any claims regarding any special features of construction or superior performance that exceed these minimum requirements. In these cases, all such claims should be verified and the test procedures should be extended or supplemented, where necessary, to verify the performance claimed by the manufacturer. When verifying the superior performance of one criterion, other performance criteria are not required to meet the standards minimum requirements, however, these reduced claimed performance criteria (as confirmed in the manufactures Installation Manual) should also be verified. (e.g. temperature range of 0 °C to 60 °C; 0 °C to 40 °C at ±10 % Close

RM 90.00

Document will be sent via email



 Add To Cart

Explosive atmospheres - Part 5: Equipment protection by powder filling “Q” (IEC 60079-5:2007, IDT) (First revision)
MS IEC 60079-5:2007 (CONFIRMED:2013)
Status : 1st Confirmation
Format : PDF

This Malaysian Standard specifies requirements for the construction, testing and marking of electrical equipment, parts of electrical equipment and Ex components in the type of protection powder filli ....Read more ng "q", intended for use in explosive gas atmospheres.

NOTE 1: Electrical equipment and Ex components protected by powder filling “q” may contain electronic circuits, transformers, protection fuses, relays, intrinsically safe electrical apparatus, associated electrical apparatus, switches, etc.

NOTE 2: Type of protection powder filling “q” provides equipment protection level (EPL) Gb.

This Malaysian Standard supplements and modifies the general requirements of MS IEC 60079-0. Where a requirement of this standard conflicts with a requirement of MS IEC 60079-0, the requirement of this standard will take precedence.
Close

RM 45.00

Document will be sent via email



 Add To Cart

Explosive atmospheres - Part 14: Electrical installations design, selection and erection (First revision) (IEC 60079-14:2007, IDT)
MS IEC 60079-14:2008 (CONFIRMED:2013)
Status : 1st Confirmation
Format : PDF

This Malaysian Standard specifies specific requirements for the design, selection and erection of electrical installations in hazardous areas associated with explosive atmospheres. This standard appli ....Read more es to all electrical equipment including fixed, portable, transportable and personal, and installations, permanent or temporary. Close

RM 165.00

Document will be sent via email



 Add To Cart

Explosive atmospheres - Part 1: Equipment protection by flameproof enclosures 'd' (Second revision) (IEC 60079-1:2007, IDT)
MS IEC 60079-1:2008 (CONFIRMED:2013)
Status : 1st Confirmation
Format : PDF

This Malaysian Standard specific requirements for the construction and testing of electrical apparatus with the type of protection flameproof enclosure 'd', intended for use in explosive gas atmospher ....Read more es. Close

RM 120.00

Document will be sent via email



 Add To Cart

Explosive atmospheres - Part 19: Equipment repair, overhaul and reclamation (Third revision) (IEC 60079-19:2010, AMD. 1:2015 , IDT)
MS IEC 60079-19:2017
Status : 3rd Revision
Format : PDF

This Malaysian Standard gives instructions, principally of a technical nature, on the repair, overhaul, reclamation and modification of equipment designed for use in explosive atmospheres;

....Read more /> a) is not applicable to maintenance, other than when repair and overhaul cannot be disassociated from maintenance, neither does it give advice on cable entry systems which may require a renewal when the equipment is re-installed;

b) is not applicable to type of protection "m", "o" and "q"; and

c) assumes that good engineering practices are adopted throughout.
Close

RM 105.00

Document will be sent via email



 Add To Cart

Power transformers Part 2: Temperature rise for liquid-immersed transformers (First revision) (IEC 60076-2:2011, MOD)
MS 60076-2:2017
Status : 1st Revision
Format : PDF

This Malaysian Standard applies to liquid-immersed transformers, identifies power transformers according to their cooling methods, defines temperature rise limits and gives the methods for temperature ....Read more rise tests. Close

RM 90.00

Document will be sent via email



 Add To Cart

Power transformers - Part 8: Application guide (IEC 60076-8: 1997, IDT)
MS IEC 60076-8:2005 (CONFIRMED:2013)
Status : Original
Format : PDF

This Malaysian Standard applies to power transformers complying with the series of publications IEC 60076.

It is intended to provide information to users about:

–certain ....Read more fundamental service characteristics of different transformer connections and magnetic circuit designs, with particular reference to zero-sequence phenomena;

–system fault currents in transformers with YNynd and similar connections;

–parallel operation of transformers, calculation of voltage drop or rise under load, and calculation of load loss for three-winding load combinations;

–selection of rated quantities and tapping quantities at the time of purchase, based on prospective loading cases;

–application of transformers of conventional design to convert or loading;–measuring technique and accuracy in loss measurement.

Malaysian Standard the information is of a general nature and applicable to all sizes of power transformers.Several chapters, however, deal with aspects and problems which are of the intere
Close

RM 135.00

Document will be sent via email



 Add To Cart

Power transformers - Part 7: Loading guide for oil-immersed power transformers (First revision) (IEC 60076-7:2005, MOD)
MS 60076-7:2012
Status : 1st Revision
Format : PDF

This Malaysian Standard specifies oil-immersed transformers that describes the effect of operation under various ambient temperatures and load conditions on transformer life. The standard provides gui ....Read more dance for the specification and loading of power transformers from the point of view of operating temperatures and thermal ageing and provides recommendation for loading above the nameplate rating and guidance for the planner to choose appropriate rated quantities and loading conditions for new installations. Close

RM 90.00

Document will be sent via email



 Add To Cart

Power transformers - Part 11: Dry-type transformers (IEC 60076-11:2004, MOD)
MS 60076-11:2012
Status : Original
Format : PDF

This Malaysian Standard specifies dry-type power transformers (including auto-transfomers) having values of highest voltage for equipment up to and including 36 kV and at least one winding operating a ....Read more t greater than 1.1 kV. Close

RM 60.00

Document will be sent via email



 Add To Cart

Power transformers - Part 12: Loading guide for dry-type power transformers (IEC 60076-12:2008, IDT)
MS IEC 60076-12:2012
Status : Original
Format : PDF

This Malaysian Standard is applicable to dry-type transformers according to the scope of IEC 60076-11. It provides the means to estimate ageing rate and consumption of lifetime of the transformer insu ....Read more lation as a function of the operating temperature, time and the loading of the transformer.

NOTE. For special applications such as wind turbine application transformers, furnace transformers, welding machine transformers, and others, the manufacturer should be consulted regarding the particular loading profile.
Close

RM 60.00

Document will be sent via email



 Add To Cart

  • ‹
  • 1
  • 2
  • ...
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • ...
  • 580
  • 581
  • ›