Recommendations for small renewable energy and hybrid systems for rural electrification - Part 1: General introduction to rural electrification
MS 62257-1:2009 (CONFIRMED:2015)
Status : 1st Confirmation
Format : PDF

Rural electrification is one of the predominant policy actions designed to increase the well being of rural populations together with improved healthcare, education, personal advancement and economica ....Read more l development. Rural electrification can be completed through connection to a national or regional electrification grid. This standard applies to cases where the grid is too far away (too costly) or the individual demand centres are too small to make grid access economic, where autonomous power systems may be used to supply these services. 

This series of standards intends to provide to different players involved in rural electrification projects (such as project developers, project implementers, installers, etc.) documents for the setting up of renewable energy and hybrid systems with AC voltage below 500 V, DC voltage below 50 V and power below 50 kVA.

These standards are recommendations:
a) to choose the right system for the right place;
b) to design the system; and
c) to operate
Close

RM 15.00

Document will be sent via email



 Add To Cart

RECOMMENDATIONS FOR SMALL RENEWABLE ENERGY AND HYBRID SYSTEMS FOR RURAL ELECTRIFICATION - PART 7-1: GENERATORS - PHOTOVOLTAIC ARRAYS
MS 62257-7-1:2010
Status : Original
Format : PDF

This Malaysian Standard specifies the general requirements for erection and operation of PV arrays in decentralized rural electrification systems. 

This Malaysian Standard gives requirem ....Read more ents for d.c. voltages below and above 120 V. However for rural electrification projects it is strongly recommended to choose a voltage in the range of extra low voltage, taking into account the assumed skills of the operators,
installers and users. Nevertheless, designers have to be aware that decreasing the voltage means increasing the current and thus transferring voltage hazards to current risks (risk of fire, etc.).

The following PV array configurations are considered:
a) single string of modules;
b) multi-string PV array; and
c) PV array divided into several sub-arrays.

Direct current systems, and photovoltaic systems in particular, pose various hazards in addition to those derived from conventional a.c. power systems, for example the ability to produce and sustain electrical arcs with cu
Close

RM 135.00

Document will be sent via email



 Add To Cart

Recommendations for small renewable energy and hybrid systems for rural electrification - Part 2: From requirements to a range of electrification systems
MS 62257-2:2009 (CONFIRMED:2015)
Status : 1st Confirmation
Format : PDF

This Malaysian Standard gives some proposal a methodological approach for the setting up and carrying out of socio-economic studies as part of the framework decentralized rural electrifcation projects ....Read more . It is addressed to project teams and in particular to expert in charge of socio-economic studies in international projects. 

The amount of detail gathered and the requisite number of experts needed would depend on the scale of the proposed project. For large projects involving many household, a detailed study would be required, for a project which involves a single or few household, the study could be truncated.

The information coming from such preliminary studies could be used for several purposes, such as more complete economic and financial studies of the electrification project.

This part of MS 62257 also provides some structures as technical solutions that could be recommended, depending on the qualitative and quantitative energy demands, consistent with the needs and financial
Close

RM 105.00

Document will be sent via email



 Add To Cart

Recommendations for small renewable energy and hybrid systems for rural electrification - Part 7-3: Generator set - Selection of generator sets for rural electrification systems
MS 62257-7-3:2010 (CONFIRMED:2015)
Status : Original
Format : PDF

The Malaysian Standard specifies the general requirements for the selection, sizing, erection and operation of generator sets in decentralised rural electrification systems. It applies to all low volt ....Read more age combustion engine electricity generator sets with a rated power up to 100 kVA, and designed for supplying electrical power to isolated sites used in systems as described in MS 62257-2. 

This Malaysian Standard is not an exhaustive resource for the design, installation, operation or maintenance of generator sets but is more focused on recommendations to provide strategies on selection and criteria which may affect the use of such generation systems in a rural electrification project.

Two cases will be considered to power a collective electrification system (microgrid) or an individual electrification system.
a) the micropower system is composed of one generator set; and
b) the micropower system is a hybrid one and the generator set is only part of it. This case is addressed in the
Close

RM 75.00

Document will be sent via email



 Add To Cart

Recommendations for small renewable energy and hybrid systems for rural electrification - Part 6: Acceptance, operation, maintenance and replacement
MS 62257-6:2009 (CONFIRMED:2015)
Status : 1st Confirmation
Format : PDF

This Malaysian Standard describes the various rules to be applied for acceptance, operation, maintenance and replacement (AOMR) of decentralised rural electrification system (DRES) which are designed ....Read more to supply electric power for sites which are not connected to a large interconnected system, or a national grid, in order to meet basic needs. 

The majority of these sites are:
a) isolated dwellings;
b) village houses;
c) community services (public lighting, pumping, health centers, places of worship or cultural activities, administrative buildings, etc.); and
d) economic activities (workshops, micro-industry, etc.).

It proposes a methodology to achieve the best technical and economic conditions for acceptance, operation, maintenance and replacement of equipment and complete system life cycle.

It does not substitute for technical manuals provided by manufacturers for each equipment. The complexity of the system and application will dictate the level of required AOMR documentation.
Close

RM 30.00

Document will be sent via email



 Add To Cart

Recommendations for small renewable energy and hybrid systems for rural electrification - Part 4: System selection and design
MS 62257-4:2009 (CONFIRMED:2015)
Status : 1st Confirmation
Format : PDF

This Malaysian Standard provides a method for describing the results to be achieved by the electrification system independently of the technical solutions that could be implemented. MS 62257-2 assess ....Read more ed the needs of the users and the different power system architectures
which can be used for meeting these needs.

In relation to the needs of the different participants to the project, functional requirements that
should be achieved by the production and distribution subsystems are listed.

In Clause 5, energy management rules to be considered are described. These are key issues as they have a great influence on the sizing of the electrification system.

In Clause 6, the information that should be provided by the system sizing process to allow the participants to select the equipment or component able to fulfill the functional requirements are listed.

To allow and facilitate the management of the micro-power plant and the maintenance of the whole electrification system, some informa
Close

RM 120.00

Document will be sent via email



 Add To Cart

Recommendations for small renewable energy and hybrid systems for rural electrification - Part 5: Protection against electrical hazards
MS 62257-5:2009 (CONFIRMED:2015)
Status : 1st Confirmation
Format : PDF

Decentralised Rural Electrification Systems (DRES) are designed to supply electric power for sites which are not connected to a large interconnected system, or a national grid, in order to
mee ....Read more t basic needs.

The majority of these sites are:
a) isolated dwellings;
b) village houses;
c) community services (public lighting, pumping, health centers, places of worship or cultural
activities, administrative buildings, etc.); and
d) economic activities (workshops, micro-industry, etc).

The DRE systems fall into three categories:
a) process electrification systems (for example for pumping);
b) individual electrification systems (IES) for single users; and
c) collective electrification systems (CES) for multiple users.

Process or individual electrification systems exclusively consist of two subsystems:
a) an electric energy generation subsystem; and
b) the user’s electrical installation.

Collective electrification systems, however, consist of 3 subsystems:
a) an electric ener
Close

RM 60.00

Document will be sent via email



 Add To Cart

Plugs, socket-outlets, vehicle connectors and vehicle inlets - Conductive charging of electric vehicles - Part 1: General requirements (IEC 62196-1:2011, IDT)
MS IEC 62196-1:2013
Status : Original
Format : PDF

This Malaysian Standard specifies definitions, classifications, characteristics and test requirements of enclosures to be used as part of switchgear and controlgear assemblies in accordance with the M ....Read more S IEC 60439 series, the rated voltage of which does not exceed 1 000 V a.c. at frequencies not exceeding 1 000 Hz, or 1 500 V d.c. and suitable for general use for either indoor or outdoor applications. Close

RM 90.00

Document will be sent via email



 Add To Cart

Secondary cells and batteries containing alkaline or other non-acid electrolytes - Safety requirements for portable sealed secondary cells, and for batteries made from them, for use in portable applications (IEC 61233:2012, IDT)
MS IEC 62133:2017
Status : Original
Format : PDF

This Malaysian Standard specifies requirements and tests for the safe operation of portable sealed secondary cells and batteries (other than button) containing alkaline or other non-acid electrolyte, ....Read more under intended use and reasonably foreseeable misuse. Close

RM 60.00

Document will be sent via email



 Add To Cart

Photovoltaic (PV) stand-alone systems - Design verification (IEC 62124:2004, IDT)
MS IEC 62124:2009 (CONFIRMED:2015)
Status : 1st Confirmation
Format : PDF

The specifications, test methods and procedures included in this document cover stand-alone photovoltaic (PV) systems. It covers systems containing one or more PV modules, a support structure, storage ....Read more batterie(s), a charge controller and typical DC loads such as lights, radio, television and refrigerators. AC loads with dedicated inverters are considered as DC loads. The load as specified by the manufacturer is an integral part of the PV system with regards to the design verification. 

The focus of the test methods and procedures in this document is limited to system performance evaluation. Individual sub-systems and components may be monitored, but only to evaluate the performance of the overall system.