Evaluation and routine testing in medical imaging departments - Part 3-5: Acceptance tests - imaging performance of computed tomography x-ray equipment (IEC 61223-3-5:2004, MOD)
MS 1982:2007 (CONFIRMED:2013)
Status : Withdrawn
Format : PDF

This Malaysian Standard applies to components of computed tomography (CT) scanners which influence the image quality, patient dose and positioning.

NOT FOR SALE

Please contact us if you are interested to purchase for reference.




FLAVOURED MILK – SPECIFICATION
MS 1980:2007
Status : Original
Format : PDF

The Malaysian Standard prescribes the requirements for flavoured milk. It shall apply to full cream and low fat flavoured milk.

RM 15.00

Document will be sent via email



 Add To Cart

PEMASANGAN ELEKTRIK DALAM BANGUNAN - KOD AMALAN
MS 1979:2011 (BM)
Status : Original
Format : PDF

Malaysian Standard ini telah pun dibangunkan berdasarkan kepada bahan sumber seperti terkandung di dalam panduan MS IEC 60364 berkenaan pemasangan elektrik pada bangunan.

Standard Malays ....Read more ia ini menyediakan keperluan bagi pemasangan elektrik LV dalam bangunan seperti rumah kediaman dan tempat tinggal, dan dalam sesetengah keadaan, bila dan di mana persamaan wujud, bagi pemasangan komersil dan industri.

Bagi pemasangan elektrik, selain daripada untuk rumah kediaman dan tempat tinggal di mana rekabentuk pemasangan elektrik akan dilaksanakan oleh jurutera elektrik rekabentuk profesional untuk pengguna yang arif, bahagian berkenaan dan yang boleh digunakan di dalam MS IEC 60364 akan terserlah menurut penilaian professional.
Close

RM 30.00

Document will be sent via email



 Add To Cart

ELECTRICAL INSTALLATIONS OF BUILDINGS - CODE OF PRACTICE
MS 1979:2007
Status : Original
Format : PDF

This Malaysian Standard has been developed based on the source material as contained in the guide to MS IEC 60364 on electrical installations of buildings.

This Malaysian Standard prov ....Read more ides the requirement for LV electrical installations of buildings such as residential houses and dwellings, and in certain circumstances, where and when similarities exist, to those in commercial and industrial installations.

For electrical installations, other than those for residential houses and dwellings where the design of the electrical installations will be carried out by professional design electrical engineers for informed consumers, the relevant and applicable sections in MS IEC 60364 will prevail in accordance to professional judgment.
Close

RM 30.00

Document will be sent via email



 Add To Cart

Electrical installations of buildings - Code of practice (First revision)
MS 1979:2015
Status : 1st Revision
Format : PDF

This Malaysian Standard provides the requirement for low voltage electrical installations of domestic dwellings and residential houses and in certain circumstances, where and when similarities exist, ....Read more to those non-domestic dwellings and residential houses.

For electrical installations, other than those for domestic dwellings and residential houses where the design of the electrical installations will be carried out by professional design electrical engineer for informed consumers, the relevant and applicable parts and sections in MS IEC 60364 will prevail in accordance to the judgement of professional electrical design engineer.
Close

RM 60.00

Document will be sent via email



 Add To Cart

TEST METHOD FOR CURING PROPERTIES OF PULTRUSION RESINS BY THERMAL ANALYSIS
MS 1978:2007
Status : Withdrawn
Format : PDF

This Malaysian Standard covers determination of curing parameters of pultrusions resins by differential scanning calorimetry.

This test method is applicable to pultrusion resin solutio ....Read more ns with adequate initiator(s).

The normal operating temperature range is from 0 to 200°C.

NOTE 1—Resin systems which do not form an adequate baseline are not covered by this test method.

Computer or electronic based instruments or data treatment equivalent to this practice may also be used.

This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. For specific hazard statements, see Note 1.

NOTE 2—There is no similar or equivalent ISO standard.
Close

NOT FOR SALE

"Please contact us if you are interested to purchase for reference."




TEST METHOD FOR COEFFICIENT OF LINEAR THERMAL EXPANSION OF PLASTICS BETWEEN -30°C AND 30°C WITH A VITREOUS SILICA DILATOMETER
MS 1977:2007
Status : Withdrawn
Format : PDF

This Malaysian Standard covers determination of the coefficient of linear thermal expansion for plastic materials having coefficients of expansion greater than 1 x 10-6 1°C by use of a vitreous silic ....Read more a dilatometer.At the test temperatures and under the stresses imposed, the plastic materials shall have a negligible creep or elastic strain rate or both, insofar as these properties would significantly affect the accuracy of the measurements.

NOTE 1—There is no similar or equivalent ISO standard.

Test Method E 228 shall be used for temperatures other than ?30°C to 30°C.

This test method shall not be used for measurements on materials having a very low coefficient of expansion (less than 1 × 10?6 1°C). For materials having very low coefficient of expansion, interferometer or capacitance techniques are recommended.

The thermal expansion of a plastic is composed of a reversible component on which are superimposed changes in length due to changes in moisture content, curing, loss of pl
Close

NOT FOR SALE

"Please contact us if you are interested to purchase for reference."




TEST METHOD FOR CARBON BLACK EXTRACTABLES – TRANSMITTANCE OF TOLUENE EXTRACT
MS 1976:2007
Status : Withdrawn
Format : PDF

This Malaysian Standard covers the measurement of the degree of toluene discoloration by carbon black extractables and is useful in controlling the reaction processes for production of carbon black.Th ....Read more is test method may not be applicable to carbon blacks with high extractables.

The values stated in SI units are to be regarded as standard.

This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
Close

NOT FOR SALE

"Please contact us if you are interested to purchase for reference."




TEST METHOD FOR IMPACT RESISTANCE OF FLAT, RIGID PLASTICS SPECIMEN BY MEANS OF A STRIKER IMPACTED BY A FALLING WEIGHT (GARDNER IMPACT)
MS 1975:2007
Status : Withdrawn
Format : PDF

This Malaysian Standard covers the determination of the relative ranking of materials according to the energy required to crack or break flat, rigid plastic specimens under various specified condition ....Read more s of impact of a striker impacted by a falling weight.

The values stated in SI units are to be regarded as the standard. The values given in brackets are for information only.1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

NOTE 1—There is no similar or equivalent ISO standard.
Close

NOT FOR SALE

"Please contact us if you are interested to purchase for reference."




PRACTICE FOR IDENTIFICATION OF POLYMER LAYERS OR INCLUSIONS BY FOURIER TRANSFORM INFRARED MICROSPECTROSCOPY (FT-IR)
MS 1974:2007
Status : Withdrawn
Format : PDF

This Malaysian Standard describes the techniques used for detecting two different polymer entities as follows:

Abnormal specks or spots on a surface or in the film that are objectionab ....Read more le as defects and

Layers of different polymeric sheets commonly used as barrier films made by coextrusion.

The values stated in SI units are to be regarded as the standard. The values given in parentheses are for information only.

This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. Specific hazard statements are given in Section 7.

NOTE 1—There is no similar or equivalent ISO standard.
Close

NOT FOR SALE

"Please contact us if you are interested to purchase for reference."




  • ‹
  • 1