BM ENG
  • Home
  • Service
  • International Standard
  • FAQ
  • Publish
  • signin
  •  Cart ()
Search Malaysian Standard (MS)
 Advanced Search Search




PLASTICS PIPING SYSTEMS FOR HOT AND COLD WATER INSTALLATIONS – POLYBUTYLENE (PB) PART 7: GUIDANCE FOR THE ASSESSMENT OF CONFORMITY (ISO/TS 15876-7:2003, MOD)
MS ISO 15876-7:2004
Status : Original
Format : PDF

This Malaysian Standard Technical Specification gives guidance for the assessment of conformity to be included in the manufacturer'squality plan as part of his quality system.

This Techn ....Read more ical Specification includes:

a) requirements for materials, components, joints and assemblies given in the applicable Part(s) ofEN ISO 15876;

b) requirements for the manufacturer's quality system;

NOTE 1 It is recommended that the quality system conforms to EN ISO 9001:2000[2].

c) definitions and procedures to be applied if third party certification is involved.

NOTE 2 If third party certification is involved, it is recommended that the certification body is accredited to EN 45011[3] or EN 45012[4], a sapplicable.

In conjunction with the other parts of EN ISO 15876 (see Foreword), this Technical Specification is applicable to polybutylene (PB) piping systems intended to be used for hot and cold water installations within buildings for theconveyance of water, whether or not intended for hu
Close

RM 30.00

Document will be sent via email



 Add To Cart

PLASTICS PIPING SYSTEMS FOR HOT AND COLD WATER INSTALLATIONS – POLYBUTYLENE (PB) PART 2 : PIPES (ISO 15876-2:2003, MOD)
MS ISO 15876-2 : 2004
Status : Original
Format : PDF

This Malaysian Standard specifies the characteristics of pipes made of polybutylene (PB) for piping systems intended to be used for hot and cold water installations within buildings for the conveyance ....Read more of water whether or not intended for human consumption (domestic systems), and for heating systems, under design pressures and temperatures appropriate to the class of application.

This standard covers a range of service conditions (application classes), design pressures and pipe dimensionclasses. For values of TD, Tmax and Tmal in excess of those in Table 1 of Part 1, this standard does not apply.

NOTE 1It is the responsibility of the purchaser or specifier to make the appropriate selections from these aspects, taking into account their particular requirements and any relevant national regulations and installation practices or codes.

It also specifies the test parameters for the test methods referred to in this standard.

In conjunction with the other Parts of EN ISO 15876 (see F
Close

RM 45.00

Document will be sent via email



 Add To Cart

PLASTICS PIPING SYSTEMS FOR HOT AND COLD WATER INSTALLATIONS – POLYBUTYLENE (PB) PART 3: FITTINGS (ISO 15876-3:2003, MOD)
MS ISO 15876-3 : 2004
Status : Original
Format : PDF

This Malaysian Standards specifies the characteristics of fittings for polybutylene (PB) piping systems intendedto be used for hot and cold water installations within buildings for the conveyance of w ....Read more ater, whether or not intendedfor human consumption (domestic systems) and for heating systems under design pressures and temperaturesaccording to the class of application (see Table 1 of EN ISO 15876-1:2003).

This standard covers a range of service conditions (application classes) and design pressure classes. For values of TD, Tmax and Tmal in excess of those in Table 1 of Part 1, this standard does not apply.

NOTE It is the responsibility of the purchaser or specifier to make the appropriate selections from these aspects, taking into account their particular requirements and any relevant national regulations and installation practices or codes.

It also specifies the parameters for the test methods referred to in this standard.

In conjunction with the other parts of EN ISO 15876 (
Close

RM 30.00

Document will be sent via email



 Add To Cart

PLASTICS PIPING SYSTEMS FOR HOT AND COLD WATER INSTALLATIONS – POLYBUTYLENE (PB) PART 5: FITNESS FOR PURPOSE OF THE SYSTEM (ISO 15876-5:2003, IDT)
MS ISO 15876-5 : 2004
Status : Original
Format : PDF

This Malaysian standard specifies the characteristics of the fitness for purpose of polybutylene (PB) piping systems, intended to be used for hot and cold water installations within buildings for the ....Read more conveyance of water,whether or not intended for human consumption, (domestic systems) and for heating systems, under design pressures and temperatures according to the class of application (see Table 1 of EN ISO 15876-1:2003).

This standard covers a range of service conditions (application classes) and design pressure classes For values of T, Tmax and Tmal in excess of those in Table 1 of Part 1, this standard does not apply.

NOTE It is the responsibility of the purchaser or specifier to make the appropriate selections from these aspects, taking into account their particular requirements and any relevant national regulations and installation practices or codes.

It also specifies the test parameters for the test methods referred to in this standard.

In conjunction with the other Pa
Close

RM 30.00

Document will be sent via email



 Add To Cart

PLASTICS PIPING SYSTEMS FOR HOT AND COLD WATER INSTALLATIONS – POLYBUTYLENE (PB) PART 1: GENERAL (ISO 15876-1:2003, MOD)
MS ISO 15876-1 : 2004
Status : Original
Format : PDF

This Malaysian Standard specifies the general aspects of polybutylene (PB) piping systems intended to be usedfor hot and cold water installations within buildings for the conveyance of water whether o ....Read more r not intended for humanconsumption (domestic systems) and for heating systems, under design pressures and temperatures according tothe class of application (see Table 1).

This standard covers a range of service conditions (application classes) and design pressure and pipe dimensionclasses. For values of TD, Tmax and Tmal in excess of those in Table 1, this standard does not apply.

NOTE It is the responsibility of the purchaser or specifier to make the appropriate selections from these aspects, taking into account theirparticular requirements and any relevant national regulations and installation practices or codes.

It also specifies the test parameters for the test methods referred to in this standard.

In conjunction with the other Parts of EN ISO 15876 (see Foreword) it is appli
Close

RM 30.00

Document will be sent via email



 Add To Cart

PLASTICS PIPING SYSTEMS FOR HOT AND COLD WATER INSTALLATIONS - POLYBUTYLENE (PB) PART 1: GENERAL (ISO 15876-1:2003, MOD)
MS ISO 15876-1:2004, AMD. 1:2009
Status : Amendment 1
Format : PDF

This Malaysian Standard specifies the general aspects of polybutylene (PB) piping systems intended to be used for hot and cold water installations within buildings for the conveyance of water whether ....Read more or not intended for human consumption (domestic systems) and for heating systems, under design pressures and temperatures according to the class of application. Close

FREE

Document will be sent via email



Please Login to enable MS to be send via email

PLASTICS PIPING SYSTEMS FOR HOT AND COLD WATER INSTALLATIONS - POLYBUTYLENE (PB) - PART 2: PIPES (ISO 15876-2:2003, MOD)
MS ISO 15876-2:2004, AMD. 1:2009
Status : Amendment 1
Format : PDF

This Malaysian Standard specifies the characteristics of pipes made of polybutylene (PB) for piping systems intended to be used for hot and cold water installations within buildings for the conveyance ....Read more of water whether or not intended for human consumption (domestic systems), and for heating systems, under design pressures and temperatures appropriate to the class of application. Close

FREE

Document will be sent via email



Please Login to enable MS to be send via email

PLASTICS - DETERMINATION OF TENSION - TENSION FATIGUE CRACK PROPAGATION -LINEAR ELASTIC FRACTURE MECHANICS(LEFM) APPROACH (ISO 15850:2002, IDT)
MS ISO 15850:2004 (CONFIRMED:2011)
Status : 1st Confirmation
Format : PDF

This standard specifies a method for measuring the propagation of a crack in a notched specimen subjected to a cyclic tensile load varying between a constant positive minimum and a constant positive m ....Read more aximum value. The test results include the crack length as a function of the number of load cycles and the crack length increase rate as a function of the stress intensity factor and energy release rate at the crack tip. The possible occurrence of discontinuities in crack propagation is detected and reported. Close

RM 45.00

Document will be sent via email



 Add To Cart

Condensed aerosol fire extinguishing systems - Requirements and test methods for components and system design, installation and maintenance - General requirements (ISO 15779:2011, MOD)
MS 15779:2015
Status : Original
Format : PDF

This Malaysian Standard specifies requirements and test methods for components and gives recommendations for the design, installation, testing, maintenance and safety of condensed aerosol firefighting ....Read more systems in buildings, plants or other structures, and the characteristics of the extinguishants and types of fire for which they are a suitable extinguishing medium. It covers total flooding systems primarily related to buildings, plant and other specific applications, utilizing electrically non-conducting condensed aerosol fire extinguishants for which there are sufficient data currently available to enable validation of performance characteristics by an appropriate independent authority. Close

RM 120.00

Document will be sent via email



 Add To Cart

PAPER AND BOARD - DETERMINATION OF z-DIRECTIONAL TENSILE STRENGTH (ISO 15754:2009, IDT)
MS ISO 15754:2010 (CONFIRMED:2023)
Status : 1st Confirmation
Format : PDF

This Malaysian Standard specifies a method for the determination of z-directional tensile strength, i.e. the tensile strength in the z-direction. It is applicable to paper and board, but not applicabl ....Read more e to corrugated fibreboard.

For papers, the grammage range can not be stated explicitly, but results for papers having a grammage less than 60 g/m2 shall be treated with caution since the tape may reinforce the paper.

This International Standard does not determine the absolute strength of paper as the measurement is affected by the tape, the pressing conditions and the speed used.