Indoor air - Part 11: Determination of the emission of volatile organic compounds from building products and furnishing - sampling, storage of samples and preparation of test specimens (ISO 16000-11:2006, IDT)
MS ISO 16000-11:2008 (CONFIRMED:2013)
Status : 1st Confirmation
Format : PDF

Studies of the emission of volatile organic compounds from unused building products or furnishing in test chambers or cells require proper handling of the product prior to testing, and during the test ....Read more ing period.

This Malaysian Standard defines three types of building products or furnishing: solid, liquid and combined. For each type, specifications are given for the sampling procedures, transport conditions, storage, and substrate used that can affect emissions of volatile organic compounds. For individual products, the preparation of a test specimen for each type is prescribed.
Close

RM 30.00

Document will be sent via email



 Add To Cart

Indoor air - Part 14: Determination of total (gas and particle-phase) polychlorinated dioxin-like biphenyls (PCBs) and polychlorinated dibenzo-p-dioxins/dibenzofurans (PCDDs/PCDFs) - extraction, clean-up and analysis by high-resolution gas chromatography and mass spectrometry (ISO 16000-14:2009, IDT)
MS ISO 16000-14:2010 (CONFIRMED:2023)
Status : 2nd Confirmation
Format : PDF

This Malaysian Standard specifies clean-up, extraction and analysis procedures for the determination of polychlorinated biphenyls (PCBs), polychlorinated dibenzo-p-dioxins (PCDDs) and polychlorinated ....Read more dibenzofurans (PCDFs) collected from indoor air on particle filters backed by polyurethane foam (PUF). This standard incorporates specific analyses by high-resolution gas chromatography combined with high-resolution mass spectrometry. Close

RM 105.00

Document will be sent via email



 Add To Cart

Indoor air - Part 4: Determination of formaldehyde - Diffusive sampling method (First revision) (ISO 16000-4:2011, IDT)
MS ISO 16000-4:2015 (CONFIRMED:2023)
Status : 1st Confirmation
Format : PDF

This Malaysian Standard specifies a determination of formaldehyde in indoor air using a diffusive sampler with solvent desorption and high performance liquid chromatography (HPLC).

The ....Read more test method is applicable to the measurement of formaldehyde in indoor air over the range from 0.001 mg/m3 to 1.0 mg/m3 for a sampling period of between 24 h and 72 h. For sampling periods of 24 h, the applicable concentration range is 0.003 mg/m3 to 1 mg/m3, and for 72 h it is 0.001 mg/m3 to 0.33 mg/m3.

The method is suitable for measurements in atmospheres with conventional indoor air relative humidity and for monitoring at air velocities as low as 0.02 m/s. The chromatographic step in the method is designed to eliminate potential interferences, including those due to the presence of other carbonyl compounds. The sampling method gives a time-weighted average result.
Close

RM 30.00

Document will be sent via email



 Add To Cart

INDOOR AIR - PART 1: GENERAL ASPECTS OF SAMPLING STRATEGY (ISO 16000-1:2004, IDT)
MS ISO 16000-1:2008 (CONFIRMED:2023)
Status : 1st Confirmation
Format : PDF

This Malaysian Standard is intended to aid the planning of indoor pollution monitoring.

Before a sampling strategy is devised for indoor air monitoring, it is necessary to clarify for ....Read more what purposes, when, where, how often and over what periods of time monitoring is to be performed. The answers to these questions depend, in particular, on a number of special characteristics of the indoor environments, on the objective of the measurement and, finally, on the environment to be measured. This Malaysian Standard deals with the significance of these factors and offers suggestions on how to develop a suitable sampling strategy.

This Malaysian Standard is applicable to indoor environments such as dwellings with living rooms, bedrooms, do-it-yourself rooms, recreation rooms and cellars, kitchens and bathrooms; workrooms or work places in buildings which are not subject to health and safety inspections in regard to air pollutants (for example, offices, sales premises); public buildings (for
Close

RM 45.00

Document will be sent via email



 Add To Cart

INDOOR AIR - PART 17: DETECTION AND ENUMERATION OF MOULDS - CULTURE-BASED METHOD (ISO 16000-17:2008, IDT)
MS ISO 16000-17:2011 (CONFIRMED:2023)
Status : 2nd Confirmation
Format : PDF

This Malaysian Standard specifies a method for the detection and enumeration of moulds by cultivation after sampling by impaction according to ISO 16000-18 or by filtration according to ISO 16000-16. ....Read more It is also suitable for cultivation of moulds from material suspensions or from direct plating. Close

RM 45.00

Document will be sent via email



 Add To Cart

INDOOR AIR - PART 16: DETECTION AND ENUMERATION OF MOULDS - SAMPLING BY FILTRATION (ISO 16000-16:2008, IDT)
MS ISO 16000-16:2011 (CONFIRMED:2023)
Status : 2nd Confirmation
Format : PDF

This Malaysian Standard specifies requirements for long-term (0,5 h to several hours) sampling of moulds in indoor air by filtration. Following the instructions given, a sample is obtained for subsequ ....Read more ent detection of moulds by cultivation after suspension according to ISO 16000-17, which is part of the complete measurement procedure. ISO 16000-16:2008 is not suitable for personal sampling. Close

RM 45.00

Document will be sent via email



 Add To Cart

Indoor air - Part 3: Determination of formaldehyde and other carbonyl compounds in indoor air and test chamber air - Active sampling method (First revision) (ISO 16000-3:2011, IDT)
MS ISO 16000-3:2015
Status : Original
Format : PDF

This Malaysian Standard specifies a determination of formaldehyde (HCHO) and other carbonyl compounds (aldehydes and ketones) in air. The method is specific to formaldehyde but, with modification, at ....Read more least 12 other aromatic as well as saturated and unsaturated aliphatic carbonyl compounds (see last paragraph) can be detected and quantified. It is suitable for determination of formaldehyde and other carbonyl compounds in the approximate concentration range 1 µg/m3 to 1 mg/m3. The sampling method gives a time-weighted average (TWA) sample. It can be used for long-term (1 h to 24 h) or short-term (5 min to 60 min) sampling of air for formaldehyde.

This Malaysian Standard specifies a sampling and analysis procedure for formaldehyde and other carbonyl compounds that involves collection from air on to adsorbent cartridges coated with 2,4-dinitrophenylhydrazine (DNPH) and subsequent analysis of the hydrazones formed by high performance liquid chromatography (HPLC) with detection by ultravi
Close

RM 60.00

Document will be sent via email



 Add To Cart

Indoor air - Part 1: General aspects of sampling strategy (ISO 16000-1:2004, IDT)
MS ISO 16000-1:2008, AMD. 1:2014
Status : Amendment 1
Format : PDF

This part of ISO 16000 is intended to aid the planning of indoor pollution monitoring.

Before a sampling strategy is devised for indoor air monitoring, it is necessary to clarify for wha ....Read more t purposes, when, where, how often and over what periods of time monitoring is to be performed. The answers to these questions depend, in particular, on a number of special characteristics of the indoor environments, on the objective of the measurement and, finally, on the environment to be measured. This part of ISO 16000 deals with the significance of these factors and offers suggestions on how to develop a suitable sampling strategy. Close

FREE

Document will be sent via email



Please Login to enable MS to be send via email

Indoor air - Part 8: Determination of local mean ages of air in buildings for characterizing ventilation conditions (ISO 16000-8:2007, IDT)
MS ISO 16000-8:2008 (CONFIRMED:2023)
Status : 2nd Confirmation
Format : PDF

This Malaysian Standard describes the use of single tracer gas for determining the local mean age of air as an indicator of ventilation conditions in a building. The procedures include concentration d ....Read more ecay and homogeneous constant emission.

The described methods are intended for air quality studies and can be used for
a) checking whether the building ventilation requirements are met,
b) estimating the adequacy of ventilation in buildings with indoor air quality problems, and
c) characterizing the strength and distribution of indoor emission sources. I

In principle, the methods can be applied to all indoor spaces, regardless of the type of ventilation used and the state of mixing of air between zones. The prevailing ventilation conditions need not be disturbed by the measurement.
Close

RM 75.00

Document will be sent via email



 Add To Cart

INDOOR AIR - PART 15: SAMPLING STRATEGY FOR NITROGEN DIOXIDE (NO2) (ISO 16000-15:2008, IDT)
MS ISO 16000-15:2011 (CONFIRMED:2023)
Status : 2nd Confirmation
Format : PDF

This Malaysian Standard specifies the planning of nitrogen dioxide indoor pollution measurements. In the case of indoor air measurements, the careful planning of sampling and the entire measurement st ....Read more rategy are of particular significance since the result of the measurement may have far-reaching consequences, for example, with regard to ascertaining the need for remedial action or the success of such an action. Close

RM 30.00