FUNCTIONAL SAFETY OF ELECTRICAL/ELECTRONIC/PROGRAMMABLE ELECTRONIC SAFETY - RELATED SYSTEMS - PART 2: REQUIREMENTS FOR ELECTRICAL/ELECTRONIC/PROGRAMMABLE ELECTRONIC SAFETY- RELATED SYSTEMS (IEC 61508-2:2000, MOD)
MS 61508-2:2010Status : Original
Format : PDF
This Malaysian Standard covers those aspects to be considered only after a thorough understanding of IEC 61508-1. This Malaysian Standard can be applies to all subsystems and their components within e ....Read more
Low-voltage switchgear and controlgear assemblies - Part 2: Power switchgear and controlgear assemblies (First revision) (IEC 61439-2:2009, IDT)
MS IEC 61439-2:2012Status : 1st Revision
Format : PDF
This Malaysian Standard defines the specific requirements of power switchgear and controlgear assemblies (PSC-ASSEMBLIES), the rated voltage of which does not exceed 1000 V a.c. or 1500 V d.c.
LOW-VOLTAGE SWITCHGEAR AND CONTROLGEAR ASSEMBLIES - PART 1: GENERAL RULES (SECOND REVISION) (IEC 61439-1:2009, IDT)
MS IEC 61439-1:2010Status : 2nd Revision
Format : PDF
This Malaysian Standards lays down the definitions and states the service conditions, construction requirements, technical characteristics and verification requirements for low-voltage switchgear and ....Read more
Conduit systems for cable management - Part 24: Particular requirements - Conduit systems buried underground (First revision) (IEC 61386-24:2004, MOD)
MS 61386-24:2010 (CONFIRMED:2015)Status : 1st Confirmation
Format : PDF
This Malaysian Standard specifies requirements and tests for conduit systems buried underground including conduits and conduit fittings for the protection and management of insulated conductors and/or ....Read more
Conduit systems for cable management - Part 21: Particular requirements - Rigid conduit systems (First revision) (IEC 61386-21:2002, MOD)
MS 61386-21:2010 (CONFIRMED:2015)Status : 1st Revision
Format : PDF
This Malaysian Standard specifies the requirements for rigid conduit systems.
CONDUIT SYSTEMS FOR CABLE MANAGEMENT - PART 23: PARTICULAR REQUIREMENTS - FLEXIBLE CONDUIT SYSTEMS (FIRST REVISION) (IEC 61386-23:2002, MOD)
MS 61386-23:2010Status : 1st Revision
Format : PDF
This Malaysian Standard specifies requirements and tests for conduit systems, including conduits and conduits fittings, for the protection and management of insulated conductors and/or cables in elect ....Read more
CONDUIT SYSTEMS FOR CABLE MANAGEMENT - PART 22: PARTICULAR REQUIREMENTS - PLIABLE CONDUIT SYSTEMS (FIRST REVISION) (IEC 61386-22:2002, MOD)
MS 61386-22:2010Status : 1st Revision
Format : PDF
This Malaysian Standard specifies requirements and tests for conduit systems, including conduits and conduits fittings, for the protection and management of insulated conductors and/or cables in elect ....Read more
CONDUIT SYSTEMS FOR CABLE MANAGEMENT - PART 1: GENERAL REQUIREMENTS (FIRST REVISION) (IEC 61386-1:2008, IDT)
MS IEC 61386-1:2010Status : 1st Revision
Format : PDF
This Malaysian Standard specifies requirements and tests for conduit systems, including conduits and conduit fittings, for the protection and management of insulated conductors and/or cables in electr ....Read more
Lamp controlgear - Part 2-8: Particular requirements for ballasts for fluorescent lamps (First revision) (IEC 61347-2-8:2006, IDT)
MS IEC 61347-2-8:2014Status : 1st Revision
Format : PDF
This IEC 61347 specifies safety requirements for ballasts, excluding resistance types, for use on a.c. supplies up to 1 000 V at 50 Hz or 60 Hz, associated with fluorescent lamps with or without pre-h ....Read more
Lamp control gear - Part 2-3: Particular requirements for a.c. and/or d.c. supplied electronic control gear for fluorescent lamps (First revision) (IEC 61347-2-3:2011, IDT)
MS IEC 61347-2-3:2014Status : 1st Revision
Format : PDF
This Malaysian Standard specifies particular safety requirements for electronic ballasts for use on a.c. supplies up to 1 000 V at 50 Hz or 60 Hz with operating frequencies deviating from the supply f ....Read more