Power systems management and associated information exchange - Data and communications security - Part 6: Security for IEC 61850
MS 62351-6:2015
Status : Original
Format : PDF

This Malaysian Standard specifies messages, procedures, and algorithms for securing the operation of all protocols based on or derived from the standard IEC 61850. This standard applies to at least th ....Read more ose protocols listed in IEC 61850-8-1, IEC 61850-9-2, and IEC 61850-6. Close

RM 30.00

Document will be sent via email



 Add To Cart

Power systems management and associated information exchange - Data and communications security - Part 4: Profiles including MMS
MS 62351-4:2015
Status : Original
Format : PDF

This Malaysian Standard specifies procedures, protocol extensions, and algorithms to facilitate securing ISO 9506 - Manufacturing Message Specification (MMS) based applications. It is intended that th ....Read more is standard be referenced as a normative part of other IEC TC 57 standards that have the need for using MMS in a secure manner. This standard represents a set of mandatory and optional security specifications to be implemented for applications when using ISO/IEC 9506 (Manufacturing Automation Specification). 

This standard contains a set of specifications that are to be used by referencing standards in order to secure information transferred when using MMS. The recommendations are based upon specific communication profile protocols used in order to convey MMS information.
Close

RM 30.00

Document will be sent via email



 Add To Cart

Power systems management and associated information exchange - Data and communications security - Part 3: Communication network and system security - Profiles including TCP/IP (IEC 62351-3:2007, MOD)
MS 62351-3:2012
Status : Original
Format : PDF

This Malaysian Standard specifies how to provide confidentiality, tamper detection, and message level authentication for SCADA and telecontrol protocols that make use of TCP/IP as a message transport ....Read more layer. Close

RM 30.00

Document will be sent via email



 Add To Cart

Power systems management and associated information exchange - Data and communications security - Part 1: Communication network and system security - Introduction to security issues (IEC TS 62351-1:2007, IDT)
MS IEC/TS 62351-1:2011
Status : Original
Format : PDF

This Malaysian Standard series is information security for power system control operations. The primary objective is to “Undertake the development of standards for security of the communication prot ....Read more ocols defined by IEC TC 57, specifically the IEC 60870-5 series, the IEC 60870-6 series, the IEC 61850 series, the IEC 61970 series, and the IEC 61968 series. Undertake the development of standards and/or technical reports on end-to-end security issues.” Close

RM 60.00

Document will be sent via email



 Add To Cart

Power systems management and associated information exchange - Data and communications security - Part 2: Glossary of terms (IEC/TS 62351-2:2008, IDT)
MS IEC/TS 62351-2:2011
Status : Original
Format : PDF

This Malaysian Standard specifies the glossary of security and related communication terms in power systems management.

RM 90.00

Document will be sent via email



 Add To Cart

GUIDANCE FOR THE CORRECT USE OF RESIDUAL CURRENT-OPERATED PROTECTIVE DEVICES (RCDs) FOR HOUSEHOLD AND SIMILAR USE
MS 62350:2010
Status : Original
Format : PDF

This Malaysian Standard provides an overview of protection availability provided by residual current operated devices (RCDs) complying with Malaysian Standards or IEC Standards for household and simil ....Read more ar uses. It highlights the main parameters influencing protection reliability and provides information on how to install and operate RCDs in relationship to their environmental conditions after installation. 

This standard gives general information concerning availability of the protection within the fixed installation and how to keep a high level of availability of protection during use (installation and maintenance). It has been published for the benefit of users, installers, specifieirs and authorities.
Close

RM 45.00

Document will be sent via email



 Add To Cart

Electrotechnical products - Determination of levels of six regulated substances (Lead, mercury, cadmium, hexavalent chromium, polybrominated biphenyls, polybrominated diphenyl ethers) (IEC 62321:2008, IDT)
MS IEC 62321:2010 (CONFIRMED:2015)
Status : 1st Confirmation
Format : PDF

This Malaysian Standard specifies the determination of the levels of lead (Pb), mercury (Hg), cadmium (Cd), hexavalent chromium (Cr(VI)) contained in inorganic and organic compounds, and two types of ....Read more brominated flame retardants, polybrominated biphenyls (PBB) and polybrominated diphenyl ethers (PBDE) contained in electrotechnical products. Close

RM 165.00

Document will be sent via email



 Add To Cart

PROTECTION AGAINST LIGHTNING-PART 3: PHYSICAL DAMAGE TO STRUCTURES AND LIFE HAZARD (FIRST REVISION) (IEC 62305-3:2006, IDT)
MS IEC 62305-3:2007
Status : 1st Revision
Format : PDF

This Malaysian Standard provides the requirements for protection of a structure against physical damage by means of a lightning protection system (LPS), and for protection against injury to living be ....Read more ings due to touch and step voltages in the vicinity of an LPS (see IEC 62305-1).

This standard is applicable to:
a) design, installation, inspection and maintenance of an LPS for structures without limitation
of their height;
b) establishment of measures for protection against injury to living beings due to touch and
step voltages.
Close

RM 225.00

Document will be sent via email



 Add To Cart

PROTECTION AGAINST LIGHTNING - PART 2: RISK MANAGEMENT (FIRST REVISION) (IEC 62305-2:2006, IDT)
MS IEC 62305-2:2007
Status : 1st Revision
Format : PDF

This Malaysian Standard is applicable to risk assessment for a structure or for a service due to lightning flashes to earth. 
Its purpose is to provide a procedure for the evaluation of such a ....Read more risk. Once an upper tolerable limit for the risk has been selected, this procedure allows the selection of appropriate protection measures to be adopted to reduce the risk to or below the tolerable limit. Close

RM 165.00

Document will be sent via email



 Add To Cart

PROTECTION AGAINST LIGHTNING - PART 1: GENERAL PRINCIPLES (FIRST REVISION) (IEC 62305-1:2006, IDT)
MS IEC 62305-1:2007
Status : 1st Revision
Format : PDF

This Malaysian Standard provides the general principles to be followed in the protection against lightning of: 

– structures including their installations and contents as well as perso ....Read more ns, 
– services connected to a structure.