• :  
BM ENG
  • Subscription
  • MS Catalogue
  • MS Pack
  • Purchase History
  • Cart
  • Hi
    !
    • My Profile
    • Portal
    • Log Out

Modal title

Widget settings form goes here

Search Malaysian Standard (MS)
 Advanced Search Search


GUIDANCE FOR EVALUATION OF PRODUCT WITH RESPECT TO SUBSTANCE-USE RESTRICTIONS IN ELECTRICAL AND ELECTRONIC PRODUCTS
MS 62476:2011
Status : Original
Format : PDF

This Malaysian Standard, which is a standard, provides a framework for the use of internationally accepted standards, tools and practices to evaluate electrical and electronic products with respect to ....Read more restricted substances. This standard can also be applied to declarable substances which are not restricted in electrical and electronic products. Close

RM 30.00

Document will be sent via email



 Add To Cart

High-current test techniques - Definitions and requirements for test currents and measuring systems (IEC 62475:2010, IDT)
MS IEC 62475:2012
Status : Original
Format : PDF

This Malaysian Standard specifies high-current testing and measurements on both high-voltage and low-voltage equipment. It deals with steady-state and short-time direct current (as e.g. encountered in ....Read more high-power d.c. testing), steady-state and short-time alternating current (as e.g. encountered in high-power a.c. testing), and impulse-current. Close

RM 165.00

Document will be sent via email



 Add To Cart

Photobiological safety of lamps and lamp systems - Part 2: Guidance on manufacturing requirements relating to non-laser optical radiation safety
MS 62471-2:2014
Status : Original
Format : PDF

This Malaysian Standard provides the basis for optical radiation safety requirements of non-laser products, serving as a guide for development of safety requirements in vertical product standards and ....Read more assisting lamp system manufacturers in the interpretation of safety information provided by the lamp manufacturers. 

It provides guidance on:
- requirements for optical radiation safety assessment;
- allocation of safety measures;
- labelling of products.

This standard does not address safety requirements of intentional exposure to optical radiation from sun tanning equipment, ophthalmic instruments or other medical/cosmetic devices whose specific safety issues are addressed through appropriate standards.
Close

RM 75.00

Document will be sent via email



 Add To Cart

Photobiological safety of lamps and lamp systems (IEC 62471:2006, IDT)
MS IEC 62471:2011 (CONFIRMED:2015)
Status : 1st Confirmation
Format : PDF

This Malaysian Standard gives guidance for evaluating the photobiological safety of lamps and lamp systems including luminaires. Specifically it specifies the exposure limits, reference measurement te ....Read more chnique and classification scheme for the evaluation and control of photobiological hazards from all electrically powered incoherent broadband sources of optical radiation, including LEDs but excluding lasers, in the wavelength range from 200 nm through 3000 nm. Close

RM 75.00

Document will be sent via email



 Add To Cart

Magnetic resonance equipment for Medical imaging - Part 1: Determination of essential image quality parameters (IEC 62464-1:2007, IDT)
MS IEC 62464-1:2009 (CONFIRMED:2015)
Status : 1st Confirmation
Format : PDF

This Malaysian standard specifies measurement procedures for the determination of many essential medical MR equipment image quality parameters. Measurement procedures as addressed in this standard are ....Read more suitable for: 

- quality assessment in the acceptance test;
- quality assurance in the constancy test.

In addition, the measurement procedures specified in this standard may also be useful for type tests, although that is not an objective of this standard.
Close

RM 135.00

Document will be sent via email



 Add To Cart

Grid connected photovoltaic systems - Minimum requirements for system documentation, commissioning tests and inspection (IEC 62446:2009, IDT)
MS IEC 62446:2012
Status : Original
Format : PDF

This Malaysian Standard defines the minimal information and documentation required to be handed over to a customer following the installation of a grid connected PV system. This standard also describe ....Read more s the minimum commissioning tests, inspection criteria and documentation expected to verify the safe installation and correct operation of the system. 

This standard is written for grid connected PV systems only and not for AC module systems or systems that utilise energy storage (e.g. batteries) or hybrid systems.

The document can also be used for periodic retesting.

This standard is for use by system designers and installers of grid connected solar PV systems as a template to provide effective documentation to a customer. By detailing the expected minimum commissioning tests and inspection criteria, it is also intended to assist in the verification / inspection of a grid connected PV system after installation and for subsequent re-inspection, maintenance or modifications.
Close

RM 45.00

Document will be sent via email



 Add To Cart

ENVIRONMENTALLY CONSCIOUS DESIGN FOR ELECTRICAL AND ELECTRONIC PRODUCTS (IEC 62430:2009, IDT)
MS IEC 62430:2010
Status : Original
Format : PDF

This Malaysian Standard specifies requirements and procedures to integrate environmental aspects into design and development processes of electrical and electronic products, including combination of p ....Read more roducts, and the materials and components of which they are composed (hereafter referred to as products). Close

RM 45.00

Document will be sent via email



 Add To Cart

Type F and type B residual current operated circuit-breakers with and without integral overcurrent protection for household and similar uses (First revision) (IEC 62423:2009, IDT)
MS IEC 62423:2012
Status : 1st Revision
Format : PDF

This standard specifies requirements and tests for Type F and Type B RCDs (Residual Current Devices). Requirements and tests given in this standard are in addition to the requirements of Type A residu ....Read more al current devices. This standard can only be used together with IEC 61008-1 and IEC 61009-1.
 
Type F RCCBs (Residual Current Circuit Breaker) and Type F RCBOs (Residual current Circuit Breaker with Overcurrent protection) with rated frequency 50 Hz or 60 Hz are intended for installations when frequency inverters are supplied between phase and neutral or phase
and earthed middle conductor and are able to provide protection in case of alternating residual sinusoidal at the rated frequency, pulsating direct residual currents and composite residual currents that may occur.

Type B RCCBs and Type B RCBOs are able to provide protection in case of alternating residual sinusoidal currents up to 1 000 Hz, pulsating direct residual currents and smooth direct residual currents.
Close

RM 60.00

Document will be sent via email



 Add To Cart

SAFETY ASPECTS FOR xDSL SIGNALS ON CIRCUITS CONNECTED TO TELECOMMUNICATION NETWORKS (DSL: DIGITAL SUBSCRIBER LINE)
MS 62367:2008
Status : Original
Format : PDF

This Malaysian Standard applies the safety implications of having xDSL signals on circuits in equipment connected to a telecommunication network, and gives rules for dealing with such equipment in the ....Read more context of the IEC 60950 series. Close

RM 30.00

Document will be sent via email



 Add To Cart

Medical electrical equipment - Recurrent test and test after repair of medical electrical equipment (IEC 62353:2007, IDT)
MS IEC 62353:2013
Status : Withdrawn
Format : PDF

This Malaysian Standard applies to testing of medical electrical equipment and medical electrical systems, hereafter referred to as ME equipment and ME systems, or parts of such equipment or systems, ....Read more which comply with MS IEC 60601-1, before putting into service, during maintenance, inspection, servicing and after repair or on occasion of recurrent tests to assess the safety of such ME equipment or ME systems or parts thereof. For equipment not built to MS IEC 60601-1 these requirements may be used taking into account the safety standards for the design and information in the instructions for use of that equipment. 

This Malaysian Standard contains tables with allowable values relating to different editions of MS IEC 60601-1. For the purpose of this standard, the application of measuring methods is independent of the edition according to which the ME equipment or ME system is designed.

This Malaysian Standard contains:

- general requirements", which contain clauses of general conce
Close

NOT FOR SALE

Please contact us if you are interested to purchase for reference.




  • ‹
  • 1
  • 2
  • ...
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • ...
  • 580
  • 581
  • ›