BM ENG
  • Subscription
  • MS Catalogue
  • MS Pack
  • Purchase History
  • Cart
  • Hi
    !
    • My Profile
    • Portal
    • Log Out

Modal title

Widget settings form goes here

Search Malaysian Standard (MS)
 Advanced Search Search


Packaging for terminally sterilized medical devices - Part 1: Requirements for materials, sterile barrier systems and packaging systems (First revision) (ISO 11607-1:2006, IDT)
MS ISO 11607-1:2009 (CONFIRMED:2015)
Status : 1st Revision
Format : PDF

This Malaysian Standard specifies the requirements and test methods for materials, preformed sterile barrier systems, sterile barrier systems and packaging systems that are intended to maintain steril ....Read more ity of terminally sterilized medical devices until the point of use. 
This standard is applicable to industry, to health care facilities, and wherever medical devices are placed in sterile barrier systems and sterilized.

This standard does not cover all requirements for sterile barrier systems and packaging systems for medical devices that are manufactured aseptically. Additional requirements might also be necessary for drug/device combinations.

This standard does not describe a quality assurance system for control of all stages of manufacture.
Close

RM 60.00

Document will be sent via email



 Add To Cart

JEWELLERY - SAMPLING OF PRECIOUS METAL ALLOYS FOR AND IN JEWELLERY AND ASSOCIATED PRODUCTS (ISO 11596:2008, IDT)
MS ISO 11596:2010
Status : Original
Format : PDF

This Malaysian Standard specifies a method of sampling precious metal jewellery alloys for the determination of the precious metal content. It is applicable to raw materials, semi-finished products an ....Read more d finished products of the jewellery alloys of precious metals. The purpose of this Standard is to define all the operations needed to obtain samples intended for the determination of the precious metal content of a particular jewellery alloy. It is intended to be applied when sampling alloys are claimed to be homogeneous. 
This Malaysian Standard does not cover alloys of precious metals used in industrial products, coins qualified as legal tender, dentistry or decorative coatings on other material. It is not intended to apply to procedures employed for the purposes of production control or for the provision of samples other than for the determination of the precious metal content.
Close

RM 30.00

Document will be sent via email



 Add To Cart

STATIONARY SOURCE EMISSIONS - DETERMINATION OF THE MASS CONCENTRATION OF NITROGEN OXIDES - NAPHTHYLETHYLENEDIAMINE PHOTOMETRIC METHOD (ISO 11564:1998 (2004), COR. 1:2000, IDT)
MS ISO 11564:2009 (CONFIRMED:2023)
Status : 2nd Confirmation
Format : PDF

This Malaysian Standard specifies a photometric method for the determination of the mass concentration of nitrogen oxides in exhaust gases from ducts or chimneys. 
The method is applicable to ....Read more the determination of the mass concentration of nitrogen oxides in exhaust gases from combustion processes, processes for surface treatment of metals and from organic chemical reactions, if necessary after removal by washing, in-furnace reduction and/or catalytic denitration, prior to their dispersion into the atmosphere.

This Malaysian Standard is applicable to the concentration range 5 mg/m3 to 1000 mg/m3 as NO2 for a sample gas volume of 1000 ml.

For gas concentrations greater than 1000 mg/m3, the determination of sample gas concentrations up to 5000 mg/m3 can be performed by diluting the sample solution or by taking an aliquot of the sample solution.

This Malaysian Standard is not applicable to the determination of dinitrogen monoxide (N2O).
Close

RM 45.00

Document will be sent via email



 Add To Cart

IRON ORES - DETERMINATION OF TIN CONTENT - FLAME ATOMIC ABSORPTION SPECTROMETRIC METHOD (FIRST REVISION) (ISO 11534:2006, IDT)
MS ISO 11534:2011
Status : 1st Revision
Format : PDF

This Malaysian Standard specifies specifies a flame atomic absorption spectrometric method for the determination of the mass fraction of tin in iron ores. This method is applicable to mass fractions o ....Read more f tin between 0.001 % and 0.015 % in natural iron ores, iron ore concentrates and agglomerates, including sinter products Close

RM 30.00

Document will be sent via email



 Add To Cart

PLASTICS - FILM AND SHEETING - DETERMINATION OF DIMENSIONAL CHANGE ON HEATING (ISO 11501:1995, IDT)
MS ISO 11501:2005 (CONFIRMED:2011)
Status : Withdrawn
Format : PDF

This standard specifies a method of determining the dimensional change, in the longitudinal and transverse directions, of plastic films and sheeting on heating. This method may be applied to plastic s ....Read more heets, whether qualified as thermoshrinking or not, up to 1 mm thick. Close

NOT FOR SALE

"Please contact us if you are interested to purchase for reference."




JEWELLERY - DETERMINATION OF PALLADIUM IN PALLADIUM JEWELLERY ALLOYS - INDUCTIVELY COUPLED PLASMA (ICP) SOLUTION-SPECTROMETRIC METHOD USING YTTRIUM AS INTERNAL STANDARD ELEMENT (ISO 11495:2008, IDT)
MS ISO 11495:2010
Status : Withdrawal without replacement
Format : PDF

This Malaysian Standard describes a method for the determination of palladium in palladium jewellery alloys, preferably within the range of fineness specified in ISO 9202, by means of inductively coup ....Read more led plasma (ICP) emission spectrometry. 
The preferred palladium content of the alloys lies between 500 ‰ (parts per thousand) and 950 ‰ palladium.

NOTE This method can be used to analyse other contents of palladium.

Palladium jewellery alloys can contain silver, indium, gallium, copper, cobalt, nickel, tin and ruthenium. The presence of these alloying elements has not been observed to interfere with the determination method. If other elements are alloyed, a check is made as to whether any interference occurs.
Close

NOT FOR SALE

"Please contact us if you are interested to purchase for reference."




JEWELLERY - DETERMINATION OF PLATINUM IN PLATINUM JEWELLERY ALLOYS - INDUCTIVELY COUPLED PLASMA (ICP) SOLUTION-SPECTROMETRIC METHOD USING YTTRIUM AS INTERNAL STANDARD ELEMENT (ISO 11494:2008, IDT)
MS ISO 11494:2010
Status : Withdrawal without replacement
Format : PDF

This Malaysian Standard describes a method for the determination of platinum in platinum jewellery alloys, preferably within the range of fineness specified in ISO 9202, by means of inductively couple ....Read more d plasma (ICP) emission spectrometry. 
The preferred platinum content of the alloys lies between 850 ‰ (parts per thousand) and 950 ‰ platinum.

NOTE This method can be used to analyse other contents of platinum.

Platinum jewellery alloys can contain silver, indium, gallium, copper, cobalt, nickel, tin and ruthenium. The presence of these alloying elements has not been observed to interfere with the determination method. If other elements are alloyed, a check is made as to whether any interference occurs.
Close

NOT FOR SALE

"Please contact us if you are interested to purchase for reference."




DETERMINATION OF PALLADIUM IN PALLADIUM JEWELLERY ALLOYS - GRAVIMETRIC DETERMINATION WITH DIMETHYLGLYOXIME (ISO 11490:1995, IDT)
MS ISO 11490:2006
Status : Withdrawal without replacement
Format : PDF

This Malaysian Standard specifies a gravimetric method for the determination of palladium in palladium jewellery alloys, preferably within the range of fineness stated in ISO 9202. 
These allo ....Read more ys which may contain silver, indium, gallium, topper, Cobalt, nickel, tin and ruthenium.
Coprecipitated elements have to be determined by a suitable method and a correction applied.
Close

NOT FOR SALE

"Please contact us if you are interested to purchase for reference."




DETERMINATION OF PLATINUM IN PLATINUM JEWELLERY ALLOYS - GRAVIMETRIC DETERMINATION BY REDUCTION WITH MERCURY (I) CHLORIDE (ISO 11489:1995, IDT)
MS ISO 11489:2007
Status : Original
Format : PDF

This Malaysian Standard specifies a gravimetric method for the determination of platinum in platinum jewellery alloys, preferably within the range of fineness stated in ISO 9202. 
The procedure ....Read more applies specifically to platinum alloys incorporating Palladium, iridium, rhodium, topper,
Cobalt, gold, ruthenium, gallium, chromium, indium and less than 5 % tungsten. Some modifications are
indicated where palladium, iridium, rhodium, gold or ruthenium are present.
Close

RM 15.00

Document will be sent via email



 Add To Cart

PAPER AND BOARD - DETERMINATION OF CIE WHITENESS, D65/10° (OUTDOOR DAYLIGHT) (ISO 11475:2004, IDT)
MS ISO 11475:2006
Status : Withdrawal without replacement
Format : PDF

This Malaysian Standard specifies the procedure to be used for determining the whiteness of papers and boards. The values obtained correspond to the visual appearance of white papers and boards with o ....Read more r without fluorescent whitening agents when they are viewed under the CIE D65 daylight illuminant. It is based on reflectance data obtained over the full visible spectral range (VIS) in contrast to the measurement of ISO brightness which is limited to the blue region of VIS. 
In addition, it specifies a method for adjustment of the UV-content to correspond to the D65 daylight illuminant[8] [9], insofar as results obtained when fluorescent whitening agents are present are dependent upon the UV-content of the radiation falling upon the sample. It is specific for the measurement of fluorescence in the blue region of the spectrum.

This method is not applicable to coloured papers containing fluorescent dyes.

This standard should be read in conjunction with ISO 2469.
Close

NOT FOR SALE

"Please contact us if you are interested to purchase for reference."




  • ‹
  • 1
  • 2
  • ...
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • ...
  • 580
  • 581
  • ›