• :  
BM ENG
  • Subscription
  • MS Catalogue
  • MS Pack
  • Purchase History
  • Cart
  • Hi
    !
    • My Profile
    • Portal
    • Log Out

Modal title

Widget settings form goes here

Search Malaysian Standard (MS)
 Advanced Search Search


Implants for surgery - Ceramic materials based on yttria-stabilized tetragonal zirconia (Y-TZP) (ISO 13356:2008, IDT)
MS ISO 13356:2011
Status : Original
Format : PDF

This Malaysian Standard specifies the characteristics of, and corresponding test methods for, a biocompatible and biostable ceramic bone-substitute material based on yttria-stabilized tetragonal zirco ....Read more nia (yttria tetragonal zirconia polycrystal, Y-TZP) for use as material for surgical implants. Close

RM 30.00

Document will be sent via email



 Add To Cart

PACKAGING – COMPLETE, FILLED TRANSPORT PACKAGES AND UNIT LOADS – VERTICAL RANDOM VIBRATION TEST
MS ISO 13355:2004
Status : Withdrawn
Format : PDF

This Malaysian Standard specifies a method to carry out a vertical random vibration test on a complete, filled transport package(s) and unit loads using a random excitation 1) .

NOT FOR SALE

"Please contact us if you are interested to purchase for reference."




TRANSPORTABLE GAS CYLINDERS - FITTING OF VALVES TO GAS CYLINDERS (ISO 13341:1997, IDT)
MS ISO 13341:2008
Status : Original
Format : PDF

This Malaysian Standard specifies the essential procedures to be followed when connecting cylinder valves to gas cylinders. It applies to all valve and cylinder combination connected with screw thread ....Read more s but excludes breathing apparatus, diving gas cylinders and fire extinguihers. It defines routines for inspection and preparation prior to valving for both taper and parallel screw threads.
Torque values are given in annex A for steel and aluminium gas cylinders.
Close

RM 30.00

Document will be sent via email



 Add To Cart

Iron ores - Determination of zinc content - Flame atomic absorption spectrometric method (ISO 13310:1997, IDT)
MS ISO 13310:2004 (CONFIRMED:2013)
Status : 1st Confirmation
Format : PDF

This Malaysian Standard specifies a flame atomic absorption spectrometric method for the determination of the zinc content of iron ores. 
This method is applicable to zinc contents between 0,00 ....Read more 1 % (m/m) and 0,5 % (m/m) in natural iron ores, iron ores concentrates and agglomerates, including sinter products. Close

RM 30.00

Document will be sent via email



 Add To Cart

Silica fume for concrete - Part 1: Definitions, requirements and conformity criteria
MS EN 13263-1:2017
Status : Original
Format : PDF

This Malaysian Standard applies to the silica fume which is a by-product of the smelting process used to produce silicon metal and ferro-silicon alloys. 
This standard gives requirements for c ....Read more hemical and physical properties for silica fume to be used as a type II addition in concrete conforming to MS 523-3 : 2010, or in mortars, grouts and other mixes.
This standard also states conformity criteria and related rules.
Close

RM 45.00

Document will be sent via email

For sale within Malaysia Only

 Add To Cart

Silica fume for concrete - Part 2: Conformity evaluation
MS EN 13263-2:2017
Status : Original
Format : PDF

This Malaysian Standard specifies the scheme for the evaluation of conformity of silica fume to EN 13263-1, including certification of conformity by a certification body. 
This standard provid ....Read more es technical rules for production control by the manufacturer, including autocontrol testing of samples, and for the tasks of the certification body. It also provides rules for actions to be followed in the event of non-conformity and the procedure for the certification of conformity. Close

RM 45.00

Document will be sent via email

For sale within Malaysia Only

 Add To Cart

Road vehicles - Reduction of misuse risk of child restraint systems - Part 2: Requirements and test procedures for correct installation (panel method) (ISO 13215-2:1999, IDT)
MS ISO 13215-2:2006 (CONFIRMED:2016)
Status : 1st Confirmation
Format : PDF

This Malaysian Standard specifies the requirements and test methods for judging if user-installed child restraints are correctly installed. 
Acceptance criteria are given for the child restrain ....Read more t when tested by the specified methods. These methods provide a measure of the effectiveness of the child restraint in preventing incorrect installation, and also cover the correctnessof use of the child harness. The method is intended for technical assessment (see 4.1). The method is not primarily intended for quality assurance or research purposes. Close

RM 30.00

Document will be sent via email



 Add To Cart

Road vehicles - Reduction of misuse risk of child restraint systems - Part 3: Prediction and assessment of Misuse by Misuse Mode and Effect Analysis (MMEA) (ISO 13215-3:1999, IDT)
MS ISO 13215-3:2006 (CONFIRMED:2016)
Status : 1st Confirmation
Format : PDF

This Malaysian Standard specifies a method to predict and quantify misuse of child restraint systems which is called Misuse Mode and Effect Analysis (MMEA). Such misuse may degrade the performance of ....Read more child restraint systems. 
As a predictive method it should be applied at an early stage, before the child restraint system is put into use by consumers. The MMEA method is recommended to be used by manufacturers of child restraint systems. However,in order to further minimize misuse of child restraint systems, this method may also be used for type approval purposes.

Being predictive implies the possibility of incompleteness and errors. Such errors can be minimized, if the proposed method is supported by the panel method [1] and by field studies. This part of ISO 13215 represents the bestpresent consensus, but should be reviewed more frequently than other Standards and revised in the light of increasing experience.
Close

RM 30.00

Document will be sent via email



 Add To Cart

Ophthalmic optics - Contact lens care products - Guidelines for determination of shelf-life (ISO 13212:1999, IDT)
MS ISO 13212:2011
Status : Original
Format : PDF

This Malaysian Standard provides guidance on the design of stability studies to use in gathering information to allow determination of shelf-life of contact lens care products. 
This standard d ....Read more oes not address studies designed to obtain information to establish the in-use stability (i.e. discard statement) of contact lens care products. Close

RM 15.00

Document will be sent via email



 Add To Cart

Child use and care articles - Baby carriers - Safety requirements and test methods - Part 2: Soft carrier
MS EN 13209-2:2015
Status : Original
Format : PDF

This Malaysian Standard specifies Safety requirements and test methods for soft carriers for children i.e. those carriers without a framed support. These carriers are designed to transport a child in ....Read more an essentially vertical position whilst attached to the carer's torso. It is essential that the carriers 
are designed to allow the carer hands free operation standing and/or walking. These carriers are use with minimum weight of child of 3.5kg.
Close

RM 30.00

Document will be sent via email

For sale within Malaysia Only

 Add To Cart

  • ‹
  • 1
  • 2
  • ...
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • ...
  • 580
  • 581
  • ›