Explosive atmospheres - Part 1: Equipment protection by flameproof enclosures 'd' (Second revision) (IEC 60079-1:2007, IDT)
MS IEC 60079-1:2008 (CONFIRMED:2013)
Status : 1st Confirmation
Format : PDF

This Malaysian Standard specific requirements for the construction and testing of electrical apparatus with the type of protection flameproof enclosure 'd', intended for use in explosive gas atmospher ....Read more es. Close

RM 120.00

Document will be sent via email



 Add To Cart

Explosive atmospheres - Part 19: Equipment repair, overhaul and reclamation (Third revision) (IEC 60079-19:2010, AMD. 1:2015 , IDT)
MS IEC 60079-19:2017
Status : 3rd Revision
Format : PDF

This Malaysian Standard gives instructions, principally of a technical nature, on the repair, overhaul, reclamation and modification of equipment designed for use in explosive atmospheres;

....Read more /> a) is not applicable to maintenance, other than when repair and overhaul cannot be disassociated from maintenance, neither does it give advice on cable entry systems which may require a renewal when the equipment is re-installed;

b) is not applicable to type of protection "m", "o" and "q"; and

c) assumes that good engineering practices are adopted throughout.
Close

RM 105.00

Document will be sent via email



 Add To Cart

Power transformers Part 2: Temperature rise for liquid-immersed transformers (First revision) (IEC 60076-2:2011, MOD)
MS 60076-2:2017
Status : 1st Revision
Format : PDF

This Malaysian Standard applies to liquid-immersed transformers, identifies power transformers according to their cooling methods, defines temperature rise limits and gives the methods for temperature ....Read more rise tests. Close

RM 90.00

Document will be sent via email



 Add To Cart

Power transformers - Part 8: Application guide (IEC 60076-8: 1997, IDT)
MS IEC 60076-8:2005 (CONFIRMED:2013)
Status : Original
Format : PDF

This Malaysian Standard applies to power transformers complying with the series of publications IEC 60076.

It is intended to provide information to users about:

–certain ....Read more fundamental service characteristics of different transformer connections and magnetic circuit designs, with particular reference to zero-sequence phenomena;

–system fault currents in transformers with YNynd and similar connections;

–parallel operation of transformers, calculation of voltage drop or rise under load, and calculation of load loss for three-winding load combinations;

–selection of rated quantities and tapping quantities at the time of purchase, based on prospective loading cases;

–application of transformers of conventional design to convert or loading;–measuring technique and accuracy in loss measurement.

Malaysian Standard the information is of a general nature and applicable to all sizes of power transformers.Several chapters, however, deal with aspects and problems which are of the intere
Close

RM 135.00

Document will be sent via email



 Add To Cart

Power transformers - Part 7: Loading guide for oil-immersed power transformers (First revision) (IEC 60076-7:2005, MOD)
MS 60076-7:2012
Status : 1st Revision
Format : PDF

This Malaysian Standard specifies oil-immersed transformers that describes the effect of operation under various ambient temperatures and load conditions on transformer life. The standard provides gui ....Read more dance for the specification and loading of power transformers from the point of view of operating temperatures and thermal ageing and provides recommendation for loading above the nameplate rating and guidance for the planner to choose appropriate rated quantities and loading conditions for new installations. Close

RM 90.00

Document will be sent via email



 Add To Cart

Power transformers - Part 11: Dry-type transformers (IEC 60076-11:2004, MOD)
MS 60076-11:2012
Status : Original
Format : PDF

This Malaysian Standard specifies dry-type power transformers (including auto-transfomers) having values of highest voltage for equipment up to and including 36 kV and at least one winding operating a ....Read more t greater than 1.1 kV. Close

RM 60.00

Document will be sent via email



 Add To Cart

Power transformers - Part 12: Loading guide for dry-type power transformers (IEC 60076-12:2008, IDT)
MS IEC 60076-12:2012
Status : Original
Format : PDF

This Malaysian Standard is applicable to dry-type transformers according to the scope of IEC 60076-11. It provides the means to estimate ageing rate and consumption of lifetime of the transformer insu ....Read more lation as a function of the operating temperature, time and the loading of the transformer.

NOTE. For special applications such as wind turbine application transformers, furnace transformers, welding machine transformers, and others, the manufacturer should be consulted regarding the particular loading profile.
Close

RM 60.00

Document will be sent via email



 Add To Cart

Power transformers - Part 10: Determination of sound levels (IEC 60076-10:2001, IDT)
MS IEC 60076-10:2005
Status : Original
Format : PDF

This Malaysian Standards defines sound pressure and sound intensity measurement methods by which sound power levels of transformers, reactors and their associated cooling auxiliaries may be determined ....Read more .

NOTE For the purpose of this standard, the term "transformer" means "transformer or reactor".

The methods are applicable to transformers and reactors covered by the IEC 60076 series, IEC 60289, IEC 60726 and the IEC 61378 series, without limitation as regards size or voltage and when fitted with their normal cooling auxiliaries.

This standard is primarily intended to apply to measurements made at the factory. Conditions on-site may be very different because of the proximity of objects, including other transformers. Nevertheless, the same general rules as are given in this standard may be followed when on-site measurements are made.
Close

RM 60.00

Document will be sent via email



 Add To Cart

POWER TRANSFORMERS - PART 5: ABILITY TO WITHSTAND SHORT CIRCUIT(IEC 60076-5:2000, IDT)
MS IEC 60076-5:2005
Status : Original
Format : PDF

This Malaysian Standards identifies the requirements for power transformers to sustain without damage the effects of over currents originated by external short circuits. It describes the calculation p ....Read more rocedures used to demonstrate the thermal ability of a power transformer to with stand such over currents and both the special test and the calculation method used to demonstrate its ability to withstand the relevant dynamic effects. The requirements apply to transformers as defined in the scope of IEC 60076-1. Close

RM 45.00

Document will be sent via email



 Add To Cart

POWER TRANSFORMERS - PART 2: TEMPERATURE RISE(IEC 60076-2:1993, IDT)
MS IEC 60076-2:2005
Status : Original
Format : PDF

This part of Malaysian Standard IEC 76 identifies transformers according to their cooling methods, defines temperature-rise limits and details the methods of test for temperature-rise measurements. It ....Read more applies to transformers as defined in the scope of IEC 76-1. Close

RM 60.00

Document will be sent via email



 Add To Cart

  • ‹