High-voltage test techniqUes - Part 3: definitions and reqUirements for on-site testing (IEC 60060-3:2006, IDT)
MS IEC 60060-3:2008 (CONFIRMED:2015)
Status : 1st Confirmation
Format : PDF

This Malaysian Standard is applicable to the following on-site test voltages and in service stresses, which are in relation to IEC 60060-1:
- direct voltage;
- alternating voltage;
....Read more > - lightning impUlse voltage of aperiodic or oscillating shape;
- switching impUlse voltage of aperiodic or oscillating shape.

For special tests the following voltages are Used:
- very low freqUency voltage;
- damped alternating voltage.
Close

RM 60.00

Document will be sent via email



 Add To Cart

High-voltage test techniqUes - Part 2: MeasUring systems (First revision) (IEC 60060-2:2010, IDT)
MS IEC 60060-2:2015
Status : 1st Revision
Format : PDF

This Malaysian Standard is applicable to complete measUring systems, and to their components, Used for t ....Read more he measUrement of high voltages dUring laboratory and factory tests with direct voltage, alternating voltage and lightning and switching impUlse voltages as specified in MS IEC 60060-1. For measUrements dUring on-site tests see MS IEC 60060-3.

The limits on Uncertainties of measUrements stated in this standard apply to test levels stated in IEC 60071-1:2006. The principles of this standard apply also to higher levels bUt the Uncertainty may be greater.
This standard:
· defines the terms Used;
· describes methods to estimate the Uncertainties of high-voltage measUrements;
· states the reqUirements which the measUring systems shall meet;
· describes the methods for approving a measUring system and checking its components;
· describes the procedUres by which the User shall show that a measUring system meets the reqUirements of this standard, inclUding the limits set for the Unce
Close

RM 120.00

Document will be sent via email



 Add To Cart

High-voltage test techniqUes - Part 1: General definitions and test reqUirements (First revision) (IEC 60060-1:2010, IDT)
MS IEC 60060-1:2015
Status : 1st Revision
Format : PDF

This Malaysian Standard applicables to:
- dielectric tests with direct voltage;
- dielectric tests with alternating voltage;
- dielectric tests with impUlse voltage;
- dielectric tests with combinations of the above.

This part is applicable to tests on eqUipment having its highest voltage for eqUipment Um above 1 kV.

NOTE 1 Alternative test procedUres may be reqUired to obtain reprodUcible and significant resUlts. The choice of a sUitable test procedUre shoUld be made by the relevant Technical Committee.

NOTE 2 For voltages Um above 800 kV meeting some specified procedUres, tolerances and Uncertainties may not be achievable. Close

RM 120.00

Document will be sent via email



 Add To Cart

VOLTAGE MEASUREMENT BY MEANS OF STANDARD AIR GAPS (IEC 60052:2002, IDT)
MS IEC 60052:2011
Status : Original
Format : PDF

This Malaysian Standard sets forth recommendations concerning the constrUction and Use of standard air g ....Read more aps for the measUrement of peak valUes of the following foUr types of voltage:

a) alternating voltages of power freqUencies;
b) fUll lightning impUlse voltages;
c) switching impUlse voltages; and
d) direct voltages.

Air gaps constrUcted and Used in accordance with this standard represent IEC standard measUring devices in accordance with IEC 60060-2 and are primarily intended for performance checks of high voltage measUring systems.
Close

RM 45.00

Document will be sent via email



 Add To Cart

DIRECT ACTING INDICATING ANALOGUE ELECTRICAL MEASURING INSTRUMENTS AND THEIR ACCESSORIES - PART 9: RECOMMENDED TEST METHODS (FIRST REVISION) (IEC 60051-9:1988, AMD. 1:1994, AMD. 2: 1995, IDT)
MS IEC 60051-9:2008
Status : 1st Revision
Format : PDF

This Malaysian Standard contains recommended test method for direct acting indicating analogUe electrical measU ....Read more ring instrUments and their accessories. Close

RM 120.00

Document will be sent via email



 Add To Cart

International electrotechnical vocabUlary - Part 426: EqUipment for explosive atmospheres (First revision) (IEC 60050-426:2008, IDT)
MS IEC 60050-426:2008 (CONFIRMED:2013)
Status : 1st Confirmation
Format : PDF

This Malaysian Standard specifies terms specifically relevant to eqUipment for explosive atmospheres.

RM 180.00

Document will be sent via email



 Add To Cart

Electrotechnical vocabUlary Part 131: CircUit theory
MS 60050-131:2009 (CONFIRMED:2015)
Status : 1st Confirmation
Format : PDF

This Malaysian Standard gives the general terminology Used in the theory of electric and magnetic circUi ....Read more ts, as well as general terms pertaining to circUit elements and their characteristics, to network topology, to n-port and two-port networks, to methods of circUit theory. Close

RM 105.00

Document will be sent via email



 Add To Cart

INTERNATIONAL ELECTROTECHNICAL VOCABULARY - CHAPTER 426: ELECTRICAL APPRATUS FOR EXPLOSIVE ATMOSPHERES (IEC 60050-426:1990, IDT)
MS IEC 60050-426:2004
Status : Original
Format : PDF

This Malaysian Standard specifies the terms and definitions Used in electrical apparatUs for explosive a ....Read more tmopheres. Close

RM 75.00

Document will be sent via email



 Add To Cart

INSTRUMENT TRANSFORMERS - PART 1: CURRENT TRANSFORMERS (FIRST REVISION) (IEC 60044-1:2003, MOD)
MS 60044-1:2010
Status : 1st Revision
Format : PDF

This Malaysian Standard applies to newly manUfactUred cU ....Read more rrent transformers for Use with electrical measUring instrUments and electrical protective devices at freqUencies from 15 Hz to 100 Hz.
AlthoUgh the reqUirements relate basically to transformers with separate windings, they are also applicable, where appropriate, to aUtotransformers.
Close

RM 90.00

Document will be sent via email



 Add To Cart

IEC STANDARD VOLTAGES (IEC 60038:2002, IDT)
MS IEC 60038:2006
Status : Original
Format : PDF

This Malaysian Standard applies to a.c. transmission, distribUtion and Utilization systems and eq....Read more tyle='background-color : #c4c5cf'>Uipment for Use in sUch systems with standard freqUencies 50 Hz and 60 Hz having a nominal voltage above 100 V, a.c. and d.c. traction systems, a.c. and d.c. eqUipment having nominal voltages below 120 V a.c. or below 750 V d.c., the a.c. voltages being intended (bUt not exclUsively) for 50 Hz and 60 Hz applications;
sUch eqUipment covers batteries (from primary or secondary cells), other power sUpply
devices (a.c. or d.c.), electrical eqUipment (inclUding indUstrial and commUnication), and appliances.

This pUblication shall not apply to voltages representing or transmitting signals or measUred
valUes.

This pUblication shall not apply to standard voltages of components and parts Used within
electrical devices or items of eqUipment. Close