LOW-VOLTAGE SWITCHGEAR AND CONTROLGEAR ASSEMBLIES – PART 2: PARTICULAR REQUIREMENTS FOR BUSBAR TRUNKING SYSTEMS (BUSWAYS) (IEC 60439-2: 2000, IDT)
MS IEC 60439-2: 2002
Status : Original
Format : PDF

This Malaysian Standard applies to busbar trunking systems (BTS) and their accessories for feeding and distributing electrical power in residential, retail, public, agricultural and industrial premise ....Read more s. It also applies to busbar trunking systems which are designed to incorporate communication and/or control systems or intended to supply luminaires through tap-off units but does not apply to supply track systems in accordance with IEC 60570. 
The busbar trunking systems considered in this standard are type-tested ASSEMBLIES (TTA) when tested in accordance with clause 8 of this standard; variations in length and angles of bends are considered to be covered.

Tap-off units may be partially type-tested ASSEMBLIES (PTTA).
Close

RM 120.00

Document will be sent via email



 Add To Cart

LOW-VOLTAGE SWITCHGEAR AND CONTROLGEAR ASSEMBLIES – PART 5: PARTICULAR REQUIREMENTS FOR ASSEMBLIES INTENDED TO BE INSTALLED OUTDOORS IN PUBLIC PLACES – CABLE DISTRIBUTION CABINETS (CDCs) FOR POWER DISTRIBUTION IN NETWORKS (IEC 60439-5:1996 and its Amendment 1:1998, IDT)
MS IEC 60439-5:2004
Status : Original
Format : PDF

This Malaysian Standard gives supplementary requirements for cable distribution cabinets (CDCs), which are stationary, type-tested assemblies (TTA) for outdoor installation in places which are exposed ....Read more to the public, but where only skilled persons have access for their use. They are for use in public three-phase systems. 
NOTE 1 – If a CDC is equipped with additional equipment (for example meters), in such a way that the main function is changed considerably, then other standards may also apply as agreed between user and manufacturer(see 7.6).

NOTE 2 – Where local regulations and practices permit, a CDC according to this standard may be used in other than public networks.
Close

RM 90.00

Document will be sent via email



 Add To Cart

CONDUITS FOR ELECTRICAL PURPOSES – OUTSIDE DIAMETERS OF CONDUITS FOR ELECTRICAL INSTALLATIONS AND THREADS FOR CONDUITS AND FITTINGS (IEC 60423: 1993, IDT)
MS IEC 60423 : 2002
Status : Original
Format : PDF

This Malaysian Standard specifies outside diameters for conduits used in electrical installations and the dimensional requirements for threads. It also specifies the dimensional requirements for threa ....Read more ds used in associated fittings. 
It is not applicable to extra-heavy duty rigid steel conduits specified in IEC981.
Close

RM 90.00

Document will be sent via email



 Add To Cart

MINERAL INSULATING OILS IN ELECTRICAL EQUIPMENT - SUPERVISION AND MAINTENANCE GUIDANCE (IEC 60422:2005, MOD)
MS 60422:2011
Status : Original
Format : PDF

This Malaysia Standard gives guidance on the supervision and maintenance of the quality of the insulating oil in electrical equipment. 
This Malaysia Standard gives guidance on the supervision ....Read more and maintenance of the quality of the insulating oil in electrical equipment.

This standard is applicable to mineral insulating oils, originally supplied conforming to IEC 60296, and used in transformers, switchgear and other electrical apparatus where oil sampling is reasonably practicable and where the normal operating conditions specified in the equipment specifications apply.

This standard assists the power equipment operator to evaluate the condition of the oil and maintain it in a serviceable condition. It also provides a common basis for the preparation of more specific and complete local codes of practice.

This standard includes recommendations on tests and evaluation procedures and outlines methods for reconditioning and reclaiming oil and the decontamination of oil contaminated w
Close

RM 75.00

Document will be sent via email



 Add To Cart

LAMPHOLDERS FOR TUBULAR FLUORESCENT LAMPS AND STARTERHOLDERS (FIRST REVISION) (IEC 60400:2004, IDT)
MS IEC 60400:2006
Status : 1st Revision
Format : PDF

This Malaysian Standard states the technical and dimensional requirements for lampholders for tubular fluorescent lamps and for starterholders, and the methods of test to be used in determining the sa ....Read more fety and the fit of the lamps in the lampholders and the starters in the starterholders. Close

RM 135.00

Document will be sent via email



 Add To Cart

Barrel thread for lampholders with shade holder ring (First Revision) (IEC 60399:2008, IDT)
MS IEC 60399:2013
Status : 1st Revision
Format : PDF

This Malaysian Standard gives the limit dimensions of thread for metal or plastic and ceramic lampholders with shade holder rings made of metal or plastic. Dimensions for 'Go' and 'Not go' gauges for ....Read more shade holder rings and for lampholders are also included. Close

RM 30.00

Document will be sent via email



 Add To Cart

Insulators for overhead lines with a nominal voltage above 1000 V - Part 1: Ceramic or glass insulator units for a.c. systems - Definitions, test methods and acceptance criteria (IEC 60383-1:1993, IDT)
MS IEC 60383-1:2013
Status : Original
Format : PDF

This Malaysian Standard applies to insulators of ceramic material or glass for use on a.c. overhead power lines with a nominal voltage greater than 1 000 V and a frequency not greater than 100 Hz. Als ....Read more o applies to insulators for use on d.c. overhead electric traction lines and applies to string insulator units, rigid overhead line insulators and to insulators of similar design when used in substations Close

RM 90.00

Document will be sent via email



 Add To Cart

Insulators for overhead lines with a nominal voltage above 1000 V - Part 2: Insulator strings and insulator sets for a.c. systems - Definitions, test methods and acceptance criteria (IEC 60383-2:1993, IDT)
MS IEC 60383-2:2013
Status : Original
Format : PDF

This Malaysian Standard applies to insulator strings and insulator sets comprising string insulator units of ceramic material or glass for use on a.c. overhead power lines with a nominal voltage great ....Read more er than 1 000 V and a frequency not greater than 100 Hz. 
This standard applies to insulator strings and insulator sets for use on d.c. overhead electric traction lines.

This standard applies to insulator strings and insulator sets of similar design when used in substations.

It may be regarded as a provisional standard for insulator strings and insulator sets for use on d.c. overhead power lines and for composite insulator sets.

The object of this standard is to prescribe standard electrical test procedures and acceptance criteria to verify the defined characteristics of insulator strings and insulator sets falling within the scope of this standard.

These tests and characteristics are intended to give a common base to designers, users and suppliers of overhead lines, insulators and
Close

RM 30.00

Document will be sent via email



 Add To Cart

Methods for measuring the performance of electric storage water-heaters for household purposes (IEC 60379:1987, IDT)
MS IEC 60379:2011 (CONFIRMED:2015)
Status : 1st Confirmation
Format : PDF

This Malaysia Standard applies to electric storage water-heaters for household purposes. 
This standard does not apply to:
1) water-heaters using other sources of energy (e.g. solar ener ....Read more gy);
2) water-heaters with more than one heated volume;
3) water-heaters without thermal insulation.
Close

RM 30.00

Document will be sent via email



 Add To Cart

Pemasangan elektrik voltan-rendah - Bahagian 4-41: Perlindungan untuk keselamatan - Perlindungan terhadap kejutan elektrik (Semakan kedua) (IEC 60364-4-41:2005, IDT)
MS IEC 60364-4-41:2012 (BM)
Status : 2nd Revision
Format : PDF

Bahagian 4-41 daripada IEC 60364 menentukan keperluan-keperluan penting berkenaan dengan perlindungan terhadap kejutan elektrik, termasuk perlindungan asas (perlindungan terhadap sentuhan secara langs ....Read more ung) dan perlindungan kegagalan (perlindungan terhadap sentuhan tidak langsung) bagi manusia dan haiwan ternakan. Ia juga membincangkan tentang penggunaan dan penyelarasan bagi keperluan-keperluan ini yang berhubung dengan pengaruh luaran. 
Keperluan juga diberikan untuk penggunaan perlindungan tambahan bagi kes-kes tertentu.
Close

RM 60.00