Sterilization of health care products - Dry heat - Requirements for the development, validation and routine control of a sterilization process for medical devices (ISO 20857:2010, IDT)
MS ISO 20857:2011 (CONFIRMED:2024)
Status : 2nd Confirmation
Format : PDF

This Malaysian Standard specifies requirements for the development, validation and routine control of a dry heat sterilization process for medical devices.

?NOTE. Although the scope of ....Read more this International Standard is limited to medical devices, it specifies requirements and provides guidance that might be applicable to other health care products.

Although this Malaysian Standard primarily addresses dry heat sterilization, it also specifies requirements and provides guidance in relation to depyrogenation processes using dry heat.

?NOTE Dry heat is often used for the depyrogenation of equipment, components and health care products and its effectiveness has been demonstrated. The process parameters for sterilization and/or depyrogenation are time and temperature. Because the conditions for depyrogenation are typically more severe than those required for sterilization, a process that has been validated for product depyrogenation will result in product sterility without additional val
Close

RM 105.00

Document will be sent via email



 Add To Cart

PETROLEUM PRODUCTS - DETERMINATION OF SULFUR CONTENT OF AUTOMOTIVE FUELS - ULTRAVIOLET FLUORESCENCE METHOD (ISO 20846:2004, IDT)
MS ISO 20846:2009
Status : Original
Format : PDF

This Malaysian Standard specifies an ultraviolet (UV) fluorescence test method for the determination of the sulfur content of motor gasolines, including those containing up to 2.7 % (m/m) oxygen, and ....Read more of diesel fuels, including those containing up to 5 % (V/V) fatty acid methyl ester (FAME), having sulfur contents in the range 3 mg/kg to 500 mg/kg. Other products may be analysed and other sulfur contents may be determined according to this test method; however, no precision data for products other than automotive fuels and for results outside the specified range have been established for this standard. Halogens interfere with this detection technique at concentrations above approximately 3 500 mg/kg.

NOTE 1 Some process catalysts used in petroleum and chemical refining might be polluted when trace amounts of sulfur-bearing materials are contained in the feedstocks.

NOTE 2 This test method may be used to determine sulfur in process feeds and may also be used to control sulfur in eff
Close

RM 30.00

Document will be sent via email



 Add To Cart

Clinical laboratory testing and in vitro diagnostic test systems - Susceptibility testing of infectious agents and evaluation of performance of antimicrobial susceptibility test devices - Part 2: Evaluation of performance of antimicrobial susceptibility test devices (ISO 20776-2:2007, IDT)
MS ISO 20776-2:2010 (CONFIRMED:2015)
Status : Withdrawn
Format : PDF

This Malaysian Standard establishes acceptable performance criteria for antimicrobial susceptibility test (AST) devices that are used to determine minimum inhibitory concentrations (MIC) and/or interp ....Read more retive category determinations of susceptible, intermediate and resistant (SIR) strains of bacteria to antimicrobial agents in medical laboratories. This Malaysian Standard specifies requirements for AST devices (including diffusion test systems) and procedures for assessing performance of such devices. It defines how a performance evaluation of an AST device is to be conducted. This Malaysian Standard has been developed to guide manufacturers in the conduct of performance evaluation studies. Close

NOT FOR SALE

Please contact us if you are interested to purchase for reference.




Cinical laboratory testing and in vitro diagnostic test systems - Susceptibility testing of infectious agents and evaluation of performance of antimicrobial susceptibility test devices - Part 1: Reference method for testing the in vitro activity of antimicrobial agents against rapidly growing aerobic bacteria involved in infectious diseases (ISO 20776-1:2006, IDT)
MS ISO 20776-1:2010 (CONFIRMED:2015)
Status : Withdrawn
Format : PDF

This Malaysian Standard describes one reference method, broth microdilution, for determination of MICs. The MIC reflects the activity of the drug under the described test conditions, and can be interp ....Read more reted for clinical management purposes by taking into account other factors, such as drug pharmacology or bacterial resistance mechanisms. This allows categorization of bacteria as “susceptible” (S), “intermediate” (I), or “resistant” (R). In addition, MIC distributions can be used to define wild type or non-wild type bacterial populations. Although clinical interpretation of the MIC value is beyond the scope of this Malaysian Standard, modifications of the basic method are required for certain antimicrobial agent - bacteria combinations to facilitate clinical interpretation. These modifications are included in a separate table. It is advisable to compare other susceptibility testing methods (e.g. routine methods or diagnostic test devices) with this reference method for validation, in ord Close

NOT FOR SALE

Please contact us if you are interested to purchase for reference.




PLASTICS - TEST SPECIMENS (ISO 20753:2008, IDT)
MS ISO 20753:2010
Status : Original
Format : PDF

This Malaysian Standard specifies dimensional requirements relating to test specimens prepared from plastics materials intended for processing by moulding, as well as to test specimens prepared by mac ....Read more hining from sheets or shaped articles. It gives, in one document, the designations and dimensions of test specimens used for the acquisition of comparable data and also other frequently used specimens. Close

RM 30.00

Document will be sent via email



 Add To Cart

FINE CERAMICS (ADVANCED CERAMICS, ADVANCED TECHNICAL CERAMICS) - DETERMINATION OF OXIDATION RESISTANCE OF NON-OXIDE MONOLITHIC CERAMICS (ISO 20509:2003, IDT)
MS ISO 20509:2006 (CONFIRMED:2025)
Status : 2nd Confirmation
Format : PDF

This Malaysian Standard describes the method of test for determining the oxidation resistance of non-oxide monolithic ceramics, such as silicon nitride and silicon carbide at high temperatures.This In ....Read more ternational Standard is intended to provide an assessment of the mass and dimensional changes of test pieces following oxidation at high temperature in an oxidizing atmosphere, and to assess whether oxidation has a significant effect on the subsequent strength. This test method may be used for materials development, quality control, characterization, and design data generation purposes. Close

RM 30.00

Document will be sent via email



 Add To Cart

FINE CERAMICS (ADVANCED CERAMICS, ADVANCED TECHNICAL CERAMICS) - DETERMINATION OF LIGHT TRANSMITTANCE OF CERAMIC FILMS WITH TRANSPARENT SUBSTRATE (ISO 20508:2003, IDT)
MS ISO 20508:2008 (CONFIRMED:2025)
Status : 1st Confirmation
Format : PDF

This Malaysian Standard specifies a test method for determining the visible light transmittance of a transparent coating material, e.g., the transparent electrode for display devices, in which a fine ....Read more ceramic thin film is coated on to a substrate. This Malaysian Standard is not applicable to deliberately coloured, uneven or non-parallel faced test pieces. A translucent medium is not included in this Malaysian Standard. Close

RM 15.00

Document will be sent via email



 Add To Cart

FINE CERAMICS (ADVANCED CERAMICS, ADVANCED TECHNICAL CERAMICS) - VOCABULARY (ISO 20507:2003, IDT)
MS ISO 20507:2008
Status : Withdrawn
Format : PDF

This Malaysian Standard provides a list of terms and associated definitions which are typically used for fine ceramic (advanced ceramic, advanced technical ceramic) materials, products, applications, ....Read more properties and processes. in the scientific and technical literature; they are given together with the corresponding terms and definitions or descriptions.

In this standard, the terms are defined using the words “fine ceramic”. The definitions apply equally to “advanced ceramics” and “advanced technical ceramics”, which are considered to be equivalent.

This standard does not include terms which, though used in the field of fine ceramics, are of a more general nature and are also well known in other fields of technology.
Close

NOT FOR SALE

"Please contact us if you are interested to purchase for reference."




FINE CERAMICS (ADVANCED CERAMICS, ADVANCED TECHNICAL CERAMICS) - TEST METHOD FOR COMPRESSIVE BEHAVIOUR OF CONTINUOUS FIBRE-REINFORCED COMPOSITES AT ROOM TEMPERATURE (ISO 20504:2006, IDT)
MS ISO 20504:2006
Status : Original
Format : PDF

This Malaysian Standard describes procedures for determination of the compressive behaviour of ceramic matrix composite materials with continuous fibre reinforcement at room temperature.This method ap ....Read more plies to all ceramic matrix composites with a continuous fibre reinforcement, uni-directional (1D), bi-directional (2D) and tri-directional (xD, with 2 < x u Close

RM 45.00

Document will be sent via email



 Add To Cart

FINE CERAMICS (ADVANCED CERAMICS, ADVANCED TECHNICAL CERAMICS) - DETERMINATION OF ADHESION OF CERAMIC COATINGS BY SCRATCH TESTING (FIRST REVISION) (ISO 20502:2005/Cor 1:2009, IDT)
MS ISO 20502:2009 (CONFIRMED:2025)
Status : 2nd Confirmation
Format : PDF

This Malaysian Standard describes a method of testing ceramic coatings by scratching with a diamond stylus. During a test, either a constant or increasing force normal to the surface under test is app ....Read more lied to the stylus so as to promote adhesive and/or cohesive failure of the coating-substrate system. The test method is suitable for evaluating ceramic coatings up to a thickness of 20 ?m and might also be suitable for evaluating other coating types and thicknesses.

The standard is intended for use in the macro (1 to 100 N) force range. The procedures may also be applicable to other force ranges. However, appropriate calibration is essential if the normal forces at which failure occurs are to be quantified.