Adhesives - Test methods for the evaluation and selection of adhesives for indoor wood products - Part 2: Resistance to delamination in severe environments (ISO 26842-2:2009, IDT)
MS ISO 26842-2:2011 (CONFIRMED:2020)
Status : 1st Confirmation
Format : PDF

This Malaysian Standard specifies guidelines for the selection, by means of delamination-resistance tests, of adhesives for use in wood products placed in severe environments, indoors or during transp ....Read more ort, in which the products are exposed to extreme changes of temperature and humidity.

A series of exposure cycles at various temperatures and humidities is provided to verify that the adhesive selected, or a product bonded with the adhesive, meets the necessary requirements for resistance to delamination.

This part of ISO 26842 is intended to help the user not only to select a suitable adhesive but also to evaluate adhesives and adhesively bonded wood products.

NOTE When actual wood products are tested using this method, the test results may not be comparable due to the fact that the test laboratory will not normally have had adequate control over the way the product was assembled.

This part of ISO 26842 is not intended for use in the qualification of structural components.
Close

RM 15.00

Document will be sent via email



 Add To Cart

Ergonomics - General approach, principles and concepts (ISO 26800:2011, IDT)
MS ISO 26800:2013 (CONFIRMED:2019)
Status : Original
Format : PDF

This Malaysian Standard presents the general ergonomics approach and specifies basic ergonomics principles and concepts. These are applicable to the design and evaluation of tasks, jobs, products, too ....Read more ls, equipment, systems, organizations, services, facilities and environments, in order to make them compatible with the characteristics, the needs and values, and the abilities and limitations of people.

The provisions and guidance given by this Malaysian Standard are intended to improve the safety, performance, effectiveness, efficiency, reliability, availability and maintainability of the design outcome throughout its life cycle, while safeguarding and enhancing the health, well-being and satisfaction of those involved or affected.
Close

RM 45.00

Document will be sent via email



 Add To Cart

Anaesthetic and respiratory equipment - Spirometers intended for the measurement of time forced expired volumes in humans (ISO 26782:2009, COR. 1:2009, IDT)
MS ISO 26782:2011 (CONFIRMED:2022)
Status : 2nd Confirmation
Format : PDF

This Malaysian Standard specifies requirements for spirometers intended for the assessment of pulmonary function in humans weighing more than 10 kg.

This Malaysian Standard applies to ....Read more a spirometer that measure timed forced expired volumes, either as part of an integrated lung function device or as a stand-alone device, irrespective of the measuring method employed.

Devices intended for continuously monitoring patients are outside the scope of this Malaysian Standard.
Close

RM 60.00

Document will be sent via email



 Add To Cart

WATER TREATMENT EQUIPMENT FOR HAEMODIALYSIS APPLICATIONS AND RELATED THERAPIES (ISO 26722:2009, IDT)
MS ISO 26722:2010
Status : Withdrawn
Format : PDF

This Malaysian Standard is addressed to the manufacturer and/or supplier of water treatment systems and/or devices used for the express purpose of providing water for haemodialysis or related therapie ....Read more s.

This standard covers devices used to treat water intended for use in the delivery of haemodialysis and related therapies. Included in the scope of this standard is water used for:

a) the preparation of concentrates from powder or other highly concentrated media at a dialysis facility;
b) the preparation of dialysis fluid that may be used for the preparation of substitution fluid;
c) the reprocessing of dialysers for multiple uses.

Included within the scope of this standard are all devices, piping and fittings between the point at which potable water is delivered to the water treatment system and the point of use of the dialysis water. Examples of devices included within the scope of this standard are water purification devices, online water quality monitors (such as conductivit
Close

NOT FOR SALE

Please contact us if you are interested to purchase for reference.




FINE CERAMICS (ADVANCED CERAMICS, ADVANCED TECHNICAL CERAMICS) - SILICON NITRIDE MATERIALS FOR ROLLING BEARING BALLS (ISO 26602:2009, IDT)
MS ISO 26602:2009
Status : Original
Format : PDF

This Malaysian Standard specifies the requirements for preprocessed silicon nitride materials for rolling bearing balls.

This Malaysian Standard provides a classification defining physic ....Read more al and mechanical properties of silicon nitride preprocessed bearing ball materials. The materials are classified in three categories by the specification of characteristics and microstructures. Methods for sample preparation and observation of microstructures are provided in Annex A.

NOTE The silicon nitride product means the sintered body of which the main component is silicon nitride material.
Close

RM 30.00

Document will be sent via email



 Add To Cart

FINE CERAMICS (ADVANCED CERAMICS, ADVANCED TECHNICAL CERAMICS) - ROCKWELL INDENTATION TEST FOR EVALUATION OF ADHESION OF CERAMIC COATINGS (ISO 26443:2008, IDT)
MS ISO 26443:2009
Status : Original
Format : PDF

This Malaysian Standard specifies a method for the qualitative evaluation of the adhesion of ceramic
coatings up to 20 ?m thick by indentation with a Rockwell diamond indenter. The formation of ....Read more cracks after indentation may also reveal cohesive failure. The indentations are made with a Rockwell hardness test instrument.

The method described in this International Standard may also be suitable for evaluating the adhesion of
metallic coatings.

The test is not suitable for elastic coatings on hard substrates.
Close

RM 30.00

Document will be sent via email



 Add To Cart

FINE CERAMICS (ADVANCED CERAMICS, ADVANCED TECHNICAL CERAMICS) - DETERMINATION OF THE ABRASION RESISTANCE OF COATINGS BY MICRO-SCALE ABRASION TEST (ISO 26424:2008, IDT)
MS ISO 26424:2009 (CONFIRMED:2025)
Status : 2nd Confirmation
Format : PDF

This Malaysian Standard specifies a method for measuring the abrasive wear rate of ceramic coatings by means of a micro-scale abrasion wear test based on the well-known crater-grinding technique used ....Read more for coating thickness determination in ISO 26423.

The method can provide data on both coating and substrate wear rates, either by performing two separate tests or by careful analysis of the data from a single test series.

The method can be applied to samples with planar or non-planar surfaces, but the results analysis described in Clause 9 applies only to flat samples. For non-planar samples, a more complicated analysis, possibly requiring the use of numerical methods, is required.
Close

RM 30.00

Document will be sent via email



 Add To Cart

Road vehicles - End-of-life activation of on-board pyrotechnic devices - Part 1: General information and use case definitions (ISO 26021-1:2008, IDT)
MS ISO 26021-1:2012
Status : Original
Format : PDF

This Malaysian Standard gives an overview of the structure of MS ISO 26021 and the way it has been divided into parts, as well as showing the relationship between the parts. In addition, it outlines t ....Read more he use case scenarios in which the MS ISO 26021 document set will be used. It also defines terminology that is used throughout the MS ISO 26021 document set. Close

RM 30.00

Document will be sent via email



 Add To Cart

Female condoms - Requirements and test methods (ISO 25841:2011, IDT)
MS ISO 25841:2013
Status : Withdrawn
Format : PDF

This Malaysian Standard specifies the minimum requirements and test methods for female condoms, which are supplied to consumers for contraceptive purposes assisting in the prevention of sexually trans ....Read more mitted infections. Close

NOT FOR SALE

Please contact us if you are interested to purchase for reference.




EXHIBITIONS, SHOWS, FAIRS AND CONVENTIONS - PART 2: MEASUREMENT PROCEDURES FOR STATISTICAL PURPOSES (ISO 25639-2:2008, IDT)
MS ISO 25639-2:2011 (CONFIRMED:2016)
Status : 1st Confirmation
Format : PDF

This Malaysian Standard establishes standard measurement procedures applicable to terms commonly used in the exhibition industry.