Low temperature, low shear rate, viscosity/ temperature dependence of lubricating oils using a temperature-scanning technique - Test method (First revision)
MS 2030:2018
Status : 1st Revision
Format : PDF

1.1 This test method covers the measurement of the apparent
viscosity of engine oil at low temperatures.
1.2 A shear rate of approximately 0.2 s-1 is produced at
shear stresses below ....Read more 100 Pa. Apparent viscosity is measured
continuously as the sample is cooled at a rate of 1 °C ⁄h over
the range −5 °C to −40 °C, or to the temperature at which the
viscosity exceeds 40 000 mPa·s (cP).
1.3 The measurements resulting from this test method are
viscosity, the maximum rate of viscosity increase (Gelation
Index), and the temperature at which the Gelation Index
occurs.
1.4 Applicability to petroleum products other than engine
oils has not been determined in preparing this test method.
1.5 The values stated in SI units are to be regarded as
standard. No other units of measurement are included in this
standard.
1.6 This standard does not purport to address all of the
safety concerns, if any, associated with its use. It is the
responsibility of the user of this standard to establish appropriate
safety and health practices and determine the applicability
of regulatory limitations prior to use.
Close

RM 30.00

Document will be sent via email



 Add To Cart

Determination of homogeneity and miscibility in automotive engine oils - Test method (First revision)
MS 2029:2018
Status : 1st Revision
Format : PDF

1.1 This test method covers the determination if an automotive
engine oil is homogeneous and will remain so, and if it is
miscible with certain standard reference oils after being submitte ....Read more d
to a prescribed cycle of temperature changes. This test
method is very similar to the homogeneity and miscibility test
described in FED–STD–791/3470.1.
1.2 The values stated in SI units are to be regarded as
standard. No other units of measurement are included in this
standard.
1.3 WARNING—Mercury has been designated by many
regulatory agencies as a hazardous material that can cause
central nervous system, kidney and liver damage. Mercury, or
its vapor, may be hazardous to health and corrosive to
materials. Caution should be taken when handling mercury and
mercury containing products. See the applicable product Material
Safety Data Sheet (MSDS) for details and EPA’s
website—http://www.epa.gov/mercury/faq.htm—for additional
information. Users should be aware that selling mercury
and/or mercury containing products into your state or country
may be prohibited by law.
1.4 This standard does not purport to address all of the
safety concerns, if any, associated with its use. It is the
responsibility of the user of this standard to establish appropriate
safety and health practices and determine the applicability
of regulatory limitations prior to use.
Close

RM 15.00

Document will be sent via email



 Add To Cart

Measuring viscosity of new and used engine oils at high shear rate and high temperature by tapered bearing simulator viscometer at 150 C - Test method (First revision)
MS 2018:2018
Status : 1st Revision
Format : PDF

1.1 This test method covers the laboratory determination of
the viscosity of engine oils at 150 °C and 1.0·106 s−1 using a
viscometer having a slightly tapered rotor and stator called ....Read more the
Tapered Bearing Simulator (TBS) Viscometer.2
1.2 The Newtonian calibration oils used to establish this test
method range from approximately 1.2 mPa·s to 7.7 mPa·s at
150 °C. The precision has only been determined for the
viscosity range 1.47 mPa·s to 5.09 mPa·s at 150 °C for the
materials listed in the precision section.
1.3 The non-Newtonian reference oil used to establish the
shear rate of 1.0·106 s−1 for this test method has a viscosity
closely held to 3.55 mPa·s at 150 °C by using the absolute
viscometry of the TBS.
1.4 Manual, semi-automated, and fully automated TBS
viscometers were used in developing the precision statement
for this test method.
1.5 Application to petroleum products such as base oils and
formulated engine oils was determined in preparing the viscometric
information for this test method.
1.6 The values stated in SI units are to be regarded as
standard. No other units of measurement are included in this
standard.
1.6.1 This test method uses the milliPascal·second (mPa·s)
as the unit of viscosity. This unit is equivalent to the centipoise
(cP).
1.7 This standard does not purport to address all of the
safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate
safety and health practices and determine the applicability
of regulatory limitations prior to use.
Close

RM 30.00

Document will be sent via email



 Add To Cart

Pour point of petroleum products - Test method (Second revision)
MS 2009:2018
Status : 1st Revision
Format : PDF

1.1 This test method covers and is intended for use on any
petroleum product.2 A procedure suitable for black specimens,
cylinder stock, and nondistillate fuel oil is described in 8.8. The ....Read more
cloud point procedure formerly part of this test method now
appears as Test Method D2500.
1.2 Currently there is no ASTM test method for automated
Test Method D97 pour point measurements.

1.3 Several ASTM test methods offering alternative procedures
for determining pour points using automatic apparatus
are available. None of them share the same designation number
as Test Method D97. When an automatic instrument is used,
the ASTM test method designation number specific to the
technique shall be reported with the results. A procedure for
testing the pour point of crude oils is described in Test Method
D5853.
1.4 The values stated in SI units are to be regarded as
standard. No other units of measurement are included in this
standard.

1.5 WARNING—Mercury has been designated by many
regulatory agencies as a hazardous material that can cause
central nervous system, kidney and liver damage. Mercury, or
its vapor, may be hazardous to health and corrosive to
materials. Caution should be taken when handling mercury and
mercury containing products. See the applicable product Material
Safety Data Sheet (MSDS) for details and EPA’s
website—http://www.epa.gov/mercury/faq.htm—for additional
information. Users should be aware that selling mercury
and/or mercury containing products into your state or country
may be prohibited by law.

1.6 This standard does not purport to address all of the
safety concerns, if any, associated with its use. It is the
responsibility of the user of this standard to establish appropriate
safety and health practices and determine the applicability
of regulatory limitations prior to use.

1.7 This international standard was developed in accordance
with internationally recognized principles on standardization
established in the Decision on Principles for the
Development of International Standards, Guides and Recommendations
issued by the World Trade Organization Technical
Barriers to Trade (TBT) Committee.
Close

RM 15.00

Document will be sent via email



 Add To Cart

OXIDATION STABILITY OF STEAM TURBINE OILS BY ROTATING PRESSURE VESSEL - TEST METHOD (FIRST REVISION)
MS 2004:2018
Status : 1st Revision
Format : PDF

1.1 This test method covers the determination of the foaming
characteristics of lubricating oils at 24 °C and 93.5 °C.
Means of empirically rating the foaming tendency and the
stab ....Read more ility of the foam are described.
1.2 WARNING—Mercury has been designated by many
regulatory agencies as a hazardous material that can cause
central nervous system, kidney and liver damage. Mercury, or
its vapor, may be hazardous to health and corrosive to
materials. Caution should be taken when handling mercury and
mercury containing products. See the applicable product Material
Safety Data Sheet (MSDS) for details and EPA’s
website—http://www.epa.gov/mercury/faq.htm—for additional
information. Users should be aware that selling mercury
and/or mercury containing products into your state or country
may be prohibited by law.
1.3 The values stated in SI units are to be regarded as the
standard. The values given in parentheses are for information
only.
1.4 This standard does not purport to address all of the
safety concerns, if any, associated with its use. It is the
responsibility of the user of this standard to establish appropriate
safety and health practices and determine the applicability
of regulatory limitations prior to use. For specific
warning statements, see Sections 7, 8, and 9.1.1.
Close

RM 30.00

Document will be sent via email



 Add To Cart

Foaming characteristics of lubricating oils - Test method (First revision)
MS 1833:2018
Status : 1st Revision
Format : PDF

This test method covers the determination of the foaming
characteristics of lubricating oils at 24 °C and 93.5 °C.
Means of empirically rating the foaming tendency and the
stabilit ....Read more y of the foam are described. Close

RM 30.00

Document will be sent via email



 Add To Cart

Kinematic viscosity of transparent and opaque liquids (and calculation of dynamic viscosity) - Test method (First revision)
MS 1831:2018
Status : 1st Revision
Format : PDF

This test method specifies a procedure for the determination
of the kinematic viscosity, ν, of liquid petroleum
products, both transparent and opaque, by measuring the time
for a vo ....Read more lume of liquid to flow under gravity through a
calibrated glass capillary viscometer. The dynamic viscosity, η,
can be obtained by multiplying the kinematic viscosity, ν, by
the density, ρ, of the liquid.
Close

RM 30.00

Document will be sent via email



 Add To Cart

FLASH AND FIRE POINTS BY CLEVELAND OPEN CUP TESTER - TEST METHOD (FIRST REVISION)
MS 1830:2018
Status : 1st Revision
Format : PDF

This test method describes the determination of the flash
point and fire point of petroleum products by a manual
Cleveland open cup apparatus or an automated Cleveland open
cup appar ....Read more atus. Close

RM 30.00

Document will be sent via email



 Add To Cart

Consumer Product Safety and Recall- Guidance in the supply chain
MS 2626:2016
Status : Original
Format : PDF

This Malaysian Standards (MS) covers elements of systems approach towards managing production of safer consumer products from inception till the disposal of a product in the supply chain. This standar ....Read more d among others helps the organization:
- identify, assess, reduce or eliminate hazards;
- manage risks by reducing them to a tolerable levels; and
- provide consumers with hazard warnings or instructions essential to the safe use or disposal of consumer products.
This Standards also provides practical guidance to supplier on consumer products recalls and other corrective actions after the products has left the manufacturing facility. Other corrective actions include, but are not limited to refunds, retrofit, repair, replacement, disposal, and public notification.
This Malaysia Standard applied to general consumer products (regulated and unregulated) BUT exclude;
Food,
Medicinal products,
Cosmetics, and
Medical devices.
Close

RM 105.00

Document will be sent via email



 Add To Cart

Medical devices - Recognized essential principles of safety and performance of medical devices - Part 1: General essential principles and additional specific essential principles for all non-IVD medical devices and guidance on the selection of standards (ISO 16142-1:2016, IDT)
MS ISO 16142-1:2019
Status : Original
Format : PDF

This part of ISO 16142, which includes the essential principles of safety and performance, identifies significant standards and guides that can be used in the assessment of conformity of a medical dev ....Read more ice to the recognized essential principles that when met, indicate a medical device is safe and performs as intended. This part of ISO 16142 identifies and describes the six general essential principles of safety and performance that apply to all medical devices, including IVD medical devices (in vitro diagnostic).

This part of ISO 16142 also identifies and describes the additional essential principles of safety and performance which need to be considered during the design and manufacturing process, which are relevant to medical devices other than IVD medical devices. Future ISO 16142-2 is intended to identify and describe the essential principles of safety and performance, which need to be considered during the design and manufacturing process of IVD medical devices.

NOTE During the design process, the manufacturer selects which of the listed design and manufacturing principles apply to the particular medical device and documents the reasons for excluding others.

This part of ISO 16142 is intended for use as guidance by medical device manufacturers, standards development organizations, authorities having jurisdiction, and conformity assessment bodies.
Close

RM 105.00

Document will be sent via email



 Add To Cart

  • ‹
  • 1
  • 2
  • ...
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • ...
  • 580
  • 581
  • ›
©2020 All rights reserved
Department of Standards Malaysia (STANDARDS MALAYSIA). Best viewed on latest browser.