13A PLUGS, SOCKET-OUTLETS, ADAPTORS AND CONNECTION UNITS - PART 2: SPECIFICATION FOR 13A SWITCHED AND UNSWITCHED SOCKET-OUTLETS (THIRD REVISION)
MS 589-2:2011
Status : 3rd Revision
Format : PDF

This Malaysian Standard specifies requirements for 13A switched and unswitched shuttered
socket-outlets for household, commercial and light industrial purposes, with particular
reference t ....Read more o safety in normal use. The socket-outlets are suitable for the connection of
portable appliances, sound-vision equipment, luminaires, etc. in a.c. circuits only, operating at
voltages not exceeding 250 V r.m.s. at 50 Hz using plugs in accordance with MS 589: Part
1:2011.
Requirements are specified for 13A shuttered socket-outlets in single or multiple
arrangements, with or without associated controlling switches, for flush mounting in suitable
boxes, e.g. complying with BS 4662, or for surface or panel mounting or for portable use.
Fixed socket-outlets are intended for use with cables complying with MS 136 or MS 2112-3
having copper conductors. Portable socket-outlets are intended for use with flexible cords,
complying with MS 140 or MS 2112-5. Socket-outlets containing devices other than fuse links,
switches and indicator lamps are outside the scope of this standard.
NOTES:
1. The titles of the publications referred to in this standard are listed on the inside back cover.
2. In order to maintain safety and interchangeability with plugs and socket-outlets it is necessary that these
products comply with the requirements of Clause 9, Clause 12 and Clause 13 of this standard, however their body
outline need not be limited at a distance of 6.35 mm from the plug engagement surface.
3. Requirements for electromagnetic compatibility are not given for the following reasons.
A switched or unswitched socket-outlet does not emit intolerable electromagnetic interference since significant
electromagnetic disturbances are only generated during insertion and withdrawal which are not continuous.
A switched or unswitched socket-outlet is mechanical by nature of construction. The product is therefore immune
from electromagnetic interference.
Close

RM 120.00

Document will be sent via email



 Add To Cart

SPECIFICATION FOR 13A PLUGS, SOCKET-OUTLETS, ADAPTORS AND CONNECTION UNITS : PART 4: SPECIFICATION FOR 13A FUSED CONNECTION UNITS : SWITCHED AND UNSWITCHED (FIRST REVISION)
MS 589: PART 4:1998
Status : 1st Revision
Format : PDF

This Part of MS 589 specifies requirements for 13 A fused fixed connection units for household,
commercial and light industrial purposes, with particular reference to safety in normal use. The....Read more r /> connection units are suitable for the connection of appliances in a.c. circuits only, operating at
voltages not exceeding 250 V r.m.s. at 50 Hz.
Requirements are specified for connection units incorporating a fuse-link complying with MS
1428: 1997.
Requirements are specified for 13 A connection units having line and neutral terminals, with or
without associated controlling switches, for flush mounting in suitable enclosures, e.g. boxes
complying with BS 4662: 1970 or for surface or panel mounting. Connecting units are intended
for use with cables complying with MS 136: 1987 having copper conductors. Connecting units
with cord outlets are additionally intended for use with flexible cords, complying with MS 140:
1987 on the load (output side). Connection units containing devices other than fuse links
switches and indicator lamps are outside the scope of this standard.
NOTES.
1. The titles of the publications referred to in this standard are listed in on page 35.
2. Requirements for electromagnetic compatibility are not given for the following reasons.
A connection units does not emit intolerable electromagnetic interference since significant electromagnetic disturbances
are only generated during insertion and withdrawal which are not continuous.
A connection units is mechanical by nature of construction. The product is therefore immune from electromagnetic
interference.
Close

RM 60.00

Document will be sent via email



 Add To Cart

SPECIFICATION FOR 13A PLUGS, SOCKET-OUTLETS, ADAPTORS AND CONNECTION UNITS PART 3 : SPECIFICATION FOR ADAPTORS (FIRST REVISION)
MS 589: PART 3:1998
Status : 1st Revision
Format : PDF

This Part of MS 589 specifies the requirements for adaptors having insulating sleeves on the
line and neutral plug pins and suitable for use with socket-outlets complying with MS 589 : Part
....Read more > 2, with particular reference to safety in normal use. Adaptors specified in this Standard are
intended for household, commercial and light industrial purposes. The adaptors are suitable for
the connection of portable appliances, sound-vision equipment, luminaires, etc., in a. c. circuits
only, operating at voltages not exceeding 250 V r.m.s. at 50 Hz.
Assemblies comprising a plug and one or more portable socket-outlets connected together by a
flexible cord or cable are not considered to be adaptors accordings to this Part of MS 589.
Devices incorporating switches, transformers, timers, thermostats or other control means are
outside the scope of this Part of MS 589.
NOTES.
1. The titles of the publications referred to in this standard are listed on the inside back cover.
2. In order to maintain safety and interchangeability with plugs and socket-outlets it is necessary that these products
comply with the requirements of clauses 9, 12 and 13 however their body outline need not be limited at a distance of
6.35 mm from the plug engagement face.
3. Requirements for electromagnetic compatibility are not given for the following reasons.
An adaptor does not emit intolerable electromagnetic interference since significant electromagnetic disturbances are only
generated during insertion and withdrawal which are not continuous.
An adaptor is mechanical by nature of construction. The product is therefore immune from electromagnetic interference.
Close

RM 135.00

Document will be sent via email



 Add To Cart

13 A Plugs, socket-outlets, adaptors and connection units - Part 1: Specification for rewirable and non-rewirable 13 A fused plugs (Fourth revision)
MS 589-1:2018
Status : 3rd Revision
Format : PDF

This Malaysian Standard specifies requirements for 13 A fused plugs having insulating sleeves
on line and neutral pins, for household, commercial and light industrial purposes, with particular....Read more r /> reference to safety in normal use. The plugs are suitable for the connection of portable
appliances, sound-vision equipment, luminaires, etc. in a.c. circuits only, operating at voltages
not exceeding 250 V r.m.s at 50 Hz. Additional requirements are included for plugs suitable for
electric vehicle charging.
Requirements are specified for plugs incorporating a fuse link conforming to BS 1362. The
plugs may be rewirable or non-rewirable complete with flexible cable. Two categories of plugs
are specified covering normal and rough use. Rewirable plugs are intended for use with flexible
cables conforming to the relevant parts of MS 2112-5 or MS 2127-4 or BS EN 50525 (see
Annex H) or IEC 60227-5 or IEC 60245-4, having conductor cross-sectional areas from
0.5 mm2 to 1.5 mm2 inclusive.
NOTE. See 19.1.
Non-rewirable plugs are intended for use with flexible cords having conductor cross-sectional
areas not exceeding 1.5 mm2.
NOTE. See 19.4.
This standard also applies to non-rewirable 13 A plugs which have the brass earth pin replaced
with a similarly dimensioned protrusion made of insulating material designated as an insulated
shutter opening device (ISOD) designed to operate the shutter mechanism of a socket-outlet
conforming to MS 589-2.
A plug is mechanical by nature of construction. The product is therefore immune from
electromagnetic interference.
Plugs incorporating electronic components detailed in Annex G are included within the scope
of this part of MS 589.
Recommendations for plug in equipment incorporating MS 589-1 plug pins are given in
Annex J.
NOTE. The titles of the publications referred to in this part of MS 589 are listed in the bibliography.
Close

RM 150.00

Document will be sent via email



 Add To Cart

13 A Plugs, socket-outlets, adaptors and connection units - Part 2: Specification for 13 A switched and unswitched socket-outlets (Fourth revision)
MS 589-2:2018
Status : 3rd Revision
Format : PDF

This Malaysian Standard specifies requirements for 13 A switched and unswitched shuttered
socket-outlets for household, commercial and light industrial purposes, with particular
reference ....Read more to safety in normal use. The socket-outlets are suitable for the connection of
portable appliances, sound-vision equipment, luminaires, etc. in a.c. circuits only, operating
at voltages not exceeding 250 V r.m.s. at 50 Hz using plugs in accordance with MS 589-1.
Additional requirements are included for socket-outlets suitable for electric vehicle charging.
Requirements are specified for 13 A shuttered socket-outlets in single or multiple
arrangements, with or without associated controlling switches, for flush mounting in suitable
boxes, e.g. conforming to BS 4662, or for surface or panel mounting or for portable use. Fixed
socket-outlets are intended for use with cables conforming to MS 2112-3 or MS 2112-4 or
BS 6004:2012 and cables to the relevant part of BS EN 50525 (see Annex H), having copper
conductors. Portable socket-outlets are intended for use with flexible cables conforming to
MS 2112-5 or relevant part of BS EN 50525. Socket-outlets incorporating fuse links, switches
and indicator lamps are included within the scope of this part of MS 589. Socket-outlets
incorporating electronic components as detailed in Annex J are included within the scope of
this part of MS 589.
Socket-outlets conforming to this standard are shuttered and therefore do not require the use
of additional means to shield the current-carrying contacts when no plug is present in the
socket-outlet.
NOTES:
1. The titles of the publications referred to in this part of MS 589 are listed in the bibliography.
2. In order to maintain safety and interchangeability with plugs and socket-outlets it is necessary that
these products conform to the requirements of Clauses 9 and 13 of this part of MS 589, however their
body outline need not be limited at a distance of 6.35 mm from the plug engagement surface.
3. Requirements for electromagnetic compatibility for socket-outlets that incorporate electronic devices
are given in Annex J.
A socket-outlet that does not incorporate electronic devices does not emit intolerable
electromagnetic interference since significant electromagnetic disturbances are only
generated during insertion and withdrawal which are not continuous.
A socket-outlet that does not incorporate electronic devices is mechanical by nature of
construction. The product is therefore immune from electromagnetic interference.
Close

RM 165.00

Document will be sent via email



 Add To Cart

13 A plugs, socket-outlets, adaptors and connection units - Part 3: Specification for adaptors (Fourth revision)
MS 589-3:2018
Status : 3rd Revision
Format : PDF

This Malaysian Standard specifies requirements for adaptors having insulating sleeves on the line and neutral plug pins and suitable for use with socket-outlets conforming to MS 589-2, with particular ....Read more reference to safety in normal use. Adaptors specified in this part of MS 589 are intended for household, commercial and light industrial purposes. The adaptors are suitable for the connection of portable appliances, sound-vision equipment, luminaires, etc., in a.c. circuits only, operating at voltages not exceeding 250 V r.m.s. at 50 Hz. Adaptors incorporating electronic components detailed in Annex H are included within this part of MS 589.
This standard also applies to shaver adaptors which have the earth pin replaced with a similarly dimensioned protrusion made of insulating material designated as an insulated shutter opening device (ISOD) designed to operate the shutter mechanism of a socket-outlet conforming to MS 589-2.
Adaptors conforming to this standard are shuttered and therefore do not require the use of additional means to shield the current-carrying contacts when no plug is present in the adapter socket-outlets.
Assemblies comprising a plug and one or more portable socket-outlets connected together by a flexible cable are not considered to be adaptors according to this part of MS 589. Devices incorporating, transformers, timers, thermostats or other control means are outside the scope of this part of MS 589.
NOTES:
1. The titles of the publications referred to in this standard are listed in the bibliography.
2. In order to maintain safety and interchangeability with plugs and socket-outlets it is necessary that these products conform to the requirements of Clauses 9, 12 and 13, however their body outline need not be limited at a distance of 6.35 mm from the plug engagement surface.
An adaptor is mechanical by nature of construction. The product is therefore immune from electromagnetic interference.
An adaptor that does not incorporate electronic devices does not emit intolerable electromagnetic interference since significant electromagnetic disturbances are only generated during insertion and withdrawal which are not continuous.
This standard does not cover travel adapters.
NOTE. Attention is drawn to BS 8546:2016, which covers travel adapters.
Close

RM 165.00

Document will be sent via email



 Add To Cart

RECOMMENDED NOMENCLATURE FOR FLOUR, STARCH, DERIVATIVES AND BY-PRODUCTS
MS 587:1979
Status : Original
Format : PDF

This Malaysian Standard defines the terms most macrofrequently
used in trade and industries concerned with flour and starch including derivatives and by-products

RM 30.00

Document will be sent via email



 Add To Cart

Swine Feeds - Specification (First Revision)
MS 586:2011 (CONFIRMED:2019)
Status : 1st Revision
Format : PDF

This standard prescribes the requirements for swine (Sus vittatus) feeds.

RM 30.00

Document will be sent via email



 Add To Cart

SPECIFICATION FOR EXTENSION PLASTER
MS 582:1979
Status : Original
Format : PDF

1.1 This standard prescribes requirements for
extension plaster, also known as extension strapping
or orthopaedic strapping for use in surgical
dressings.
1 .2 Extension plaste ....Read more r is used for the support of
slight sprains which are not immobilised, of joints
and limbs after the removal of plaster casts, and
of fractured ribs. It is also used for traction
bandaging and attachment of dressings.
Close

RM 15.00

Document will be sent via email



 Add To Cart

INJECTION-MOULDED UNPLASTICIZED POLY(VINYL CHLORIDE) (PVC-U) FITTINGS – OVEN TEST – TEST METHOD AND BASIC SPECIFICATIONS (ISO 580:1990, IDT)
MS ISO 580:2003 (CONFIRMED:2019)
Status : Original
Format : PDF

This Malaysian Standard was developed by the Working Group on PVC Pipes and Fittings
under the authority of the Plastics and Plastics Products Industry Standards Committee.
This Malaysian ....Read more Standard is identical with ISO 580:1990, ‘Injection-moulded Unplasticized
poly(vinyl chloride) (PVC-U) fittings – Oven test – Test method and basic specifications’,
published by the International Organization for Standardization (ISO), which has the same
title. The text of the International Standard is recommended for publication as a Malaysian
Standard without deviation. However, for the purpose of this Malaysian Standard, the
following apply:
a) in the source text, “this International Standard” should read “this Malaysian Standard”;
and
b) the comma which is used as a decimal sign (if any), to read as a full point.
Compliance with a Malaysian Standard does not of itself confer immunity from legal
obligations.
NOTE. IDT on the front cover indicates an identical standard i.e. a standard where the technical content, structure,
wording and presentation of a Malaysian Standard is exactly the same as in an International Standard or is identical
in technical content and it may contain the minimal editorial changes specified in clause 4.2 of ISO/IEC Guide 21.
Close

RM 15.00

Document will be sent via email



 Add To Cart

  • ‹
  • 1
  • 2
  • ...
  • 499
  • 500
  • 501
  • 502
  • 503
  • 504
  • 505
  • ...
  • 580
  • 581
  • ›
©2020 All rights reserved
Department of Standards Malaysia (STANDARDS MALAYSIA). Best viewed on latest browser.