• :  
BM ENG
  • Subscription
  • MS Catalogue
  • MS Pack
  • Purchase History
  • Cart
  • Hi
    !
    • My Profile
    • Portal
    • Log Out

Modal title

Widget settings form goes here

Search Malaysian Standard (MS)
 Advanced Search Search


Classification of environmental conditions - Part 3: Classification of groups of environmental parameters and their severities - Section 1: Storage (IEC 60721-3-1:1997, IDT)
MS IEC 60721-3-1:2005 (CONFIRMED:2013)
Status : 1st Confirmation
Format : PDF

This Malaysian Standard classifies the groups of environmental parameters and their severities to which products, together with their packaging if any, are subjected when stored.  
The environ ....Read more mental conditions specified in this standard are limited to those which may directly
affect the products or their ultimate performance. Only environmental conditions as such are
considered. No special description of the effects of these conditions on the products is given.

Transfer during storage is not included in the classification.

Environmental conditions directly related to fire or explosion and conditions related to ionizing
radiation are excluded. Any other unforeseen incidents are also excluded. The possibility of
their occurrence should be taken into account in special cases. Offshore locations are not
included.

Conditions of stationary use, portable and non-stationary use, use in vehicles and ships, and
conditions of transportation are given in other sections of IEC 60721-3.
Close

RM 45.00

Document will be sent via email



 Add To Cart

Classification of environmental conditions - Part 2: Environmental conditions appearing in nature - Section 5: Dust, sand and salt mist (IEC 60721-2-5:1991, IDT)
MS IEC 60721-2-5:2005 (CONFIRMED:2013)
Status : 1st Confirmation
Format : PDF

This Malaysian Standard presents characteristics of dust, sand and salt mist appearing in nature, and describes the influences from these environmental factors to which products are liable to be expos ....Read more ed during storage, transportation and use. Although the effect of these factors is often closely associated with and at times enhanced by wind, the environmental factor of wind is not dealt with in this section but in IEC 721-2-2. Close

RM 30.00

Document will be sent via email



 Add To Cart

Classification of environmental conditions - Part 3: Classification of groups of environmental parameters and their severities - Introduction (IEC 60721-3-0:2002, IDT)
MS IEC 60721-3-0:2005 (CONFIRMED:2013)
Status : 1st Confirmation
Format : PDF

This Malaysian Standard covering the extreme (short-term) conditions which may be met by a product when being transported, installed, stored and used. Separate groups of classes are given for differen ....Read more t product applications (e.g. weather-protected stationary, mounted in ground vehicles, transportation). The classes also take into account the degree of restriction of the use of the product from very restricted conditions (e.g. in temperature-controlled rooms) to unrestricted conditions. 
The classification covers natural as well as man-made conditions.
Close

RM 30.00

Document will be sent via email



 Add To Cart

Classification of environmental conditions - Part 2: Environmental conditions appearing in nature - Earthquake vibration and shock (IEC 60721-2-6:1990, IDT)
MS IEC 60721-2-6:2005 (CONFIRMED:2013)
Status : 1st Confirmation
Format : PDF

This Malaysian Standard specifies an environmental conditions appearing in nature, and in particular related to earthquake vibration and shock. It is intended to define some fundamental properties and ....Read more quantities for characterisation of earthquake as background material for the severities to which products are liable to be exposed during storage and use. Close

RM 30.00

Document will be sent via email



 Add To Cart

Classification of environmental conditions - Part 3-7: Classification of groups of environmental parameters and their severities - Portable and non-stationary use (IEC 60721-3-7:2002, IDT)
MS IEC 60721-3-7:2005 (CONFIRMED:2013)
Status : Original
Format : PDF

This Malaysian Standard classifies groups of environmental parameters and their severities to which products are subjected during portable and non-stationary use, including periods of transfer,
....Read more > down time, maintenance and repair.

The environmental conditions covered by these groups include:
– the environmental conditions at locations where the product may be placed or used
temporarily;
– the change of environmental parameters due to change of location;
– the environmental conditions related to transfer of the product between different locations.

The environmental conditions classified do not take into account the use profile of the product, i.e. whether the product is used only during a temporary stationary state, during the state of transfer or arbitrarily.

The conditions of portable and non-stationary use to which products may be exposed include land-based and offshore, weatherprotected and non-weatherprotected locations. The conditions further include transfer which is a p
Close

RM 60.00

Document will be sent via email



 Add To Cart

Classification of environmental conditions - Part 3: Classification of groups of environmental parameters and their severities - Section 5: Ground vehicles installations (IEC 60721-3-5:1997, IDT)
MS IEC 60721-3-5:2005 (CONFIRMED:2025)
Status : 2nd Confirmation
Format : PDF

This Malaysian standard classifies the environmental conditions to which a product not forming part of the vehicle is subjected when installed in a ground vehicle. Such products are for example radios ....Read more ,communication systems, fare meters, flow meters for liquids transported by the vehicle, for example milk, petroleum products, etc. Vehicles where products may be permanently or temporarily installed include 
- road vehicles: passenger cars, commercial vehicles, special vehicles, towing vehicles,
trailers, mopeds, motor cycles, etc.;

- rail vehicles: trains, trams, cranes, etc.;

- overland vehicles: four wheel drive cars, tractors, snow scooters, etc.;

- handling and storage vehicles: fork-lift trucks (manual and robot), luggage transporters, etc.;

- self-propelled machinery: diggers, harvesters, etc.

Although this standard is not designed for products forming part of the vehicles, the environmental condition classification may also be used for some exchangeable parts, installed
Close

RM 60.00

Document will be sent via email



 Add To Cart

Household and similar electrical appliances - Test code for the determination of airborne acoustical noise - Part 2-7: Particular requirements for fan (IEC 60704-2-7:1997, IDT)
MS IEC 60704-2-7:2007 (CONFIRMED:2015)
Status : Withdrawal without replacement
Format : PDF

This Malaysian Standard applies to electrical fans (including their accessories and their component parts) for household and similar use, designed for a.c. or d.c. supply. Motor, impeller and their ho ....Read more using, if any, form a single unit. Applies to table fans, pedestal fans, ceiling fans and partition fans. Close

NOT FOR SALE

"Please contact us if you are interested to purchase for reference."




Household and similar electrical appliances - Test code for the determination of of airborne acoustical noise - Part 1: General requirements (IEC 60704-1:1997, IDT)
MS IEC 60704-1:2007 (CONFIRMED:2013)
Status : Withdrawal without replacement
Format : PDF

This Malaysian Standard applies to electric appliances (including their accessories or components) for household and similar use, supplied from mains or from batteries. By similar use is understood th ....Read more e use in similar conditions as in household, for example in inns, coffee-house, tea-rooms, hotels, barber or hairdresser shops, launderettes, etc., if not otherwise specified in Part 2. Close

NOT FOR SALE

"Please contact us if you are interested to purchase for reference."




STANDARD METHOD OF MEASURING THE PINCH TEMPERATURE OF QUARTZ-TUNGSTEN- HALOGEN LAMPS
MS IEC 60682 : 2003
Status : Original
Format : PDF

This Malaysian standard specifies details of the type of thermocouple to be used to measure the pinch temperature of quartz-tungsten-halogen lamps, the methods of preparation of the lamp and thermocou ....Read more ple, and the measurement to be made. Close

RM 45.00

Document will be sent via email



 Add To Cart

Switches for household and similar fixed electrical installations - Part 2-3: Particular requirements - Time-delay switches (TDS) (Third revision) (IEC 60669-2-3:2006, IDT)
MS IEC 60669-2-3:2012
Status : 3rd Revision
Format : PDF

This Malaysian Standard applies to time-delay switches (hereinafter referred to as TDS) with a rated voltage not exceeding 440 V and a rated current not exceeding 63 A, intended for household and simi ....Read more lar fixed electrical installations, either indoors or outdoors, operated by hand and/or by remote control. TDS are provided with a time-delay device operated by mechanical, thermal, pneumatic, hydraulic or electrical means or by a combination of them. Close

RM 30.00

Document will be sent via email



 Add To Cart

  • ‹
  • 1
  • 2
  • ...
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • ...
  • 587
  • 588
  • ›