• :  
BM ENG
  • Subscription
  • MS Catalogue
  • MS Pack
  • Purchase History
  • Cart
  • Hi
    !
    • My Profile
    • Portal
    • Log Out

Modal title

Widget settings form goes here

Search Malaysian Standard (MS)
 Advanced Search Search


Insulation coordination for equipment within low-voltage systems - Part 4: Consideration of high-frequency voltage stress (IEC 60664-4:2005, IDT)
MS IEC 60664-4:2014
Status : Original
Format : PDF

This Malaysian Standard deals with basic, supplementary and reinforced insulation subjected to high-frequency voltage stress within low-voltage equipment. The dimensioning values directly apply for ba ....Read more sic insulation; for reinforced insulation additional requirements apply according to Part 1. It is applicable for the dimensioning of clearances, creepage distances and solid insulation stressed by any type of periodic voltages with a fundamental frequency above 30 kHz and up to 10 MHz. Close

RM 105.00

Document will be sent via email



 Add To Cart

Insulation coordination for equipment within low-voltage systems - Part 5: Comprehensive method for determining clearances and creepage distances equal to or less than 2 mm (IEC 60664-5:2007, IDT)
MS IEC 60664-5:2014
Status : Original
Format : PDF

This Malaysian Standard specifies the dimensioning of clearances and creepage distances for spacings equal to or less than 2 mm for printed wiring board and equivalent constructions, where the clearan ....Read more ce and the creepage distance are identical and are along the surface of solid insulation. The dimensioning in this standard is more precise than that provided by IEC 60664-1. However, if the precision provided by this standard is not required, IEC 60664-1 may be applied instead.
This standard is based on the following criteria for dimensioning: - minimum clearances independent of the micro-environment; - minimum creepage distances for pollution degrees 1, 2 and 3 to avoid failure due to tracking; - minimum creepage distances to avoid flashover across the insulating surface
Close

RM 75.00

Document will be sent via email



 Add To Cart

Insulation coordination for equipment within low-voltage systems - Part 1: Principles, requirements and tests (IEC 60664-1:2007, IDT)
MS IEC 60664-1:2014
Status : Original
Format : PDF

This Malaysian Standard deals with insulation coordination for equipment within low-voltage systems. It applies to equipment for use up to 2 000 m above sea level having a rated voltage up to a.c. 1 0 ....Read more 00 V with rated frequencies up to 30 kHz, or a rated voltage up to d.c. 1 500 V. It specifies the requirements for clearances, creepage distances and solid insulation for equipment based upon their performance criteria. It includes methods of electric testing with respect to insulation coordination.

The minimum clearances specified in this standard do not apply where ionized gases occur. Special requirements for such situations may be specified at the discretion of the relevant technical committee.
Close

RM 120.00

Document will be sent via email



 Add To Cart

Insulation coordination for equipment within low-voltage systems - Part 2-1: Application guide - Explanation of the application of the MS IEC 60664 series, dimensioning examples and dielectric testing
MS 60664-2-1:2015
Status : Original
Format : PDF

This Malaysian Standard, provides an application guide for manufacturers specifying dimensioning requirements for products in accordance with the MS IEC 60664 series. 
The significant items for ....Read more consideration are as follows:

a) nominal system voltage(s) or rated insulation voltage(s);
b) overvoltage category of the products (OV cat);
c) any type of overvoltages;
d) frequency of the voltage;
e) characteristics of the solid insulating material; and

f) pollution degree and humidity levels.
Close

RM 105.00

Document will be sent via email



 Add To Cart

High pressure sodium vapour lamps - Performance specifications (Second Revision) (IEC 60662:2011, IDT)
MS IEC 60662:2013
Status : 2nd Revision
Format : PDF

This Malaysian Standard specifies performance requirements for high-pressure sodium vapour lamps for general lighting purposes. It includes: - restriction to performance requirements - introduction of ....Read more a test device for ignition; - split of the lamp data sheets which make use of the test device and those which do not; - provisions for measurement during starting, measurement of electrical and photometrical characteristics and tests for lumen maintenance and life; - general review e.g. of maximum lamp outlines and alignment of data; - new order of data sheets by wattage. Close

RM 270.00

Document will be sent via email



 Add To Cart

Medical electrical equipment - Part 1-2: General requirements for safety - Collateral standard electromagnetic compatibility - Requirements and test (IEC 60601-1-2:2001, IDT)
MS IEC 60601-1-2:2007 (CONFIRMED:2013)
Status : 1st Confirmation
Format : PDF

This Malaysian Standard specifies requirements and tests for electromagnetic compatibility of equipment and systems and serves as the basis of electromagnetic compatibility requirements and tests in P ....Read more articular Standards (60601-2-series). Close

RM 165.00

Document will be sent via email



 Add To Cart

Medical electrical equipment - Part 2-52: Particular requirements for the basic safety and essential performance of medical beds (IEC 60601-2-52:2009, IDT)
MS IEC 60601-2-52:2011 (CONFIRMED:2015)
Status : 1st Confirmation
Format : PDF

This Malaysian Standard applies to the basic safety and essential performance of medical beds intended for adults, hereafter referred to as medical bed.

RM 135.00

Document will be sent via email



 Add To Cart

Medical electrical equipment - Part 2-47: Particular requirements for the basic safety and essential performance of ambulatory electrocardiographic systems (First revision) (IEC 60601-2-47:2012, IDT)
MS IEC 60601-2-47:2017
Status : 1st Revision
Format : PDF

This Malaysian Standard applies the BASIC SAFETY and ESSENTIAL PERFORMANCE of AMBULATORY ELECTROCARDIOGRAPHIC SYSTEMS, hereafter referred to as ME SYSTEMS. 
If a clause or subclause is specific ....Read more ally intended to be applicable to ME EQUIPMENT only, or to ME SYSTEMS only, the title and content of that clause or subclause will say so. If that is not the case, the clause or subclause applies both to ME EQUIPMENT and to ME SYSTEMS, as relevant.

Within the scope of this standard are systems of the following types:

a) systems that provide continuous recording and continuous analysis of the ECG allowing full re-analysis giving essentially similar results. The systems may first record and store the ECG and analyse it later on a separate unit, or record and analyse the ECG simultaneously. The type of storage media used is irrelevant with regard to this standard;

b) systems that provide continuous analysis and only partial or limited recording not allowing a full re-analysis of the ECG.
Close

RM 105.00

Document will be sent via email



 Add To Cart

MEDICAL ELECTRICAL EQUIPMENT – PART 2-7: PARTICULAR REQUIREMENTS FOR THE SAFETY OF HIGH-VOLTAGE GENERATORS OF DIAGNOSTIC X-RAY GENERATORS (IEC 60601-2-7:1998, IDT)
MS IEC 60601-2-7:2007
Status : Withdrawn
Format : PDF

This Malaysian Standard applies to high-voltage generators of medical diagnostic x-ray generators and to their subassemblies including that are integrated with an x-ray tube assembly and of radiothera ....Read more py treatment simulators. Where appropriate, the requirements for x-ray generators are given but only where these concern the functioning of the associated high-voltage generators.  Close

NOT FOR SALE

Please contact us if you are interested to purchase for reference.




Medical electrical equipment - Part 2-16: Particular requirements for basic safety and essential performance of haemodialysis, haemodiafiltration and haemofiltration equipment (First revision) (IEC 60601-2-16:2012, IDT)
MS IEC 60601-2-16:2017
Status : 1st Revision
Format : PDF

This Malaysian Standard applies to the basic safety and essential performance of haemodialysis, haemodiafiltration and haemofiltration equipment. 
This standard does not take into consideration ....Read more the dialysis fluid control system of Haemodialysis equipment using regeneration of dialysis fluid and central delivery systems. It does however take into consideration the specific safety requirements of such haemodialysis equipment concerning electrical safety and patient safety.

This standard specifies the minimum safety requirements for haemodialysis equipment. These devices are intended for use either by medical staff or for use by the patient or other trained personnel under the supervision of medical expertise.

This standard includes all electromedical equipment that is intended to deliver a haemodialysis, haemodiafiltration and haemofiltration treatment to a patient suffering from kidney failure
Close

RM 105.00

Document will be sent via email



 Add To Cart

  • ‹
  • 1
  • 2
  • ...
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • ...
  • 580
  • 581
  • ›