Bayonet lampholders (First revision) (IEC 61184:2008, IDT)
MS IEC 61184:2014
Status : 1st Revision
Format : PDF

This Malaysian Standard applies to bayonet lampholders B15d and B22d for connection of lamps and semi-luminaires to a supply voltage of 250 V. 
This standard also covers lampholders which are i ....Read more ntegral with a luminaire or intended to be built into appliances. It covers the requirements for the lampholder only.

For all other requirements, such as protection against electric shock in the area of the terminals, the requirements of the relevant appliance standard shall be observed and tested after building into the appropriate equipment, when that equipment is tested according to its own standard. Lampholders for use by luminaire manufacturers only are not for retail sale. Where lampholders are used in luminaires, their maximum operating temperatures are specified in IEC 60598-1. B15 denotes the cap/holder fit as defined by IEC 60061-1, sheet 7004-11 and IEC 60061-2, sheet 7005-16 with the corresponding gauges. B22 denotes the cap/holder fit as defined by IEC 60061-1, sheet 7004-10 and IE
Close

RM 105.00

Document will be sent via email



 Add To Cart

HIGH-VOLTAGE TEST TECHNIQUES FOR LOW-VOLTAGE EQUIPMENT - PART 1: DEFINITIONS, TEST AND PROCEDURE REQUIREMENTS (IEC 61180-1:1992, IDT)
MS IEC 61180-1:2010
Status : Original
Format : PDF

This Malaysian Standard is applicable to: 
– dielectric tests with direct voltage;
– dielectric tests with alternating voltage;
– dielectric tests with impulse voltage;
....Read more /> – tests with impulse current;
– tests with combinations of the above.

This standard is applicable only to tests on equipment having a rated voltage of not more than 1 kV a.c. or 1,5 kV d.c. This standard is mainly applicable to type testing. It may also be applied or adapted for sample and routine testing as specified by the relevant technical committee. It is not intended to be used for electromagnetic compatibility tests on electric or electronic equipment. This standard provides the relevant technical committees as far as possible with:
– defined terms of both general and specific applicability;
– general requirements regarding test objects and test procedures;
- methods for generation and measurement of test voltages and currents;
– test procedures;
- methods for the evaluation of test results and to indi
Close

NOT FOR SALE

"Please contact us if you are interested to purchase for reference."




HIGH-VOLTAGE TEST TECHNIQUES FOR LOW-VOLTAGE EQUIPMENT - PART 2: TEST EQUIPMENT (IEC 61180-2:1994, IDT)
MS IEC 61180-2:2010
Status : Original
Format : PDF

This Malaysian Standard is applicable to the test equipment used for dielectric tests on low-voltage equipment. It covers tests with direct, alternating or impulse voltage, impulse current, and tests ....Read more with a combination of impulse voltage and impulse current. Verification procedures necessary for ensuring that the dielectric tests comply with the voltage, or current, requirements stated in part 1 of this standard in shape and magnitude are stated. The test equipment comprises a voltage and/or current generator and a measuring system. 

This standard covers test equipment in which the measuring system is protected against external interference and coupling by appropriate screening, for example a continuous conducting shield. Therefore, simple comparison tests are sufficient to ensure valid
results. Test equipment having measuring systems composed of non-screened components and/or connected by long leads is not covered in this standard. In this case guidance can be obtained from IEC 60-2
Close

NOT FOR SALE

"Please contact us if you are interested to purchase for reference."




METAL HALIDE LAMPS
MS IEC 61167:1999
Status : Original
Format : PDF

This International Standard specifies the methods of test to be used for determining the characteristics of metal halide lamps, both single-ended and double-ended, operated on a.c. mains, 50 Hz or 60 ....Read more Hz, with ballasts satisfying the requirements of lEC 923. Close

RM 60.00

Document will be sent via email



 Add To Cart

Industrial communication networks - Fieldbus specification - Part 1: Overview and guidance for the IEC 61158 and IEC 61784 series
MS 61158-1:2011
Status : Original
Format : PDF

This Malaysian Standard presents an overview and guidance for the IEC 61158 series by: 
a) explaining the structure and content of the IEC 61158 series;

b) relating the structure ....Read more of the IEC 61158 series to the ISO/IEC 7498 OSI Basic Reference
Model;

c) showing the logical structure of the IEC 61784 series;

d) showing how to use parts of the IEC 61158 series in combination with IEC 61784 series;
and

e) providing explanations of some aspects of the IEC 61158 series that are common to the
parts of the IEC 61158-5 series.

e) providing explanations of some aspects of the IEC 61158 series that are common to the parts of the IEC 61158-5 series.
Close

RM 105.00

Document will be sent via email



 Add To Cart

Industrial communication networks - Fieldbus specification - Part 2: Physical layer specifications and service definition (IEC 61158-2:2010, IDT)
MS IEC 61158-2:2011
Status : Original
Format : PDF

This Malaysian Standard specifies the requirements for fieldbus component parts. It also specifies the media and network configuration requirements necessary to ensure agreed levels of: a) data integr ....Read more ity before data-link Layer error checking; b) interoperability between devices at the physical layer. 
The fieldbus physical layer conforms to layer 1 of the OSI 7-layer model as defined by
ISO 7498 with the exception that, for some types, frame delimiters are in the physical layer while for other types they are in the data-link Layer.
Close

RM 585.00

Document will be sent via email



 Add To Cart

Industrial communication networks - Fieldbus specifications - Part 3-1: Data-link layer service definition - Type 1 elements (IEC 61158-3-1:2007, IDT)
MS IEC 61158-3-1:2011
Status : Original
Format : PDF

This Malaysian Standard provides common elements for basic time-critical messaging communications between devices in an automation environment. The term "time-critical" is used to represent the presen ....Read more ce of a time-window, within which one or more specified actions are required to be completed with some defined level of certainty. Failure to complete specified actions within the time window risks failure of the applications requesting the actions, with attendant risk to equipment, plant and possibly human life. Close

RM 180.00

Document will be sent via email



 Add To Cart

Industrial communication networks - Fieldbus specifications - Part 3-2: Data-link layer service definition - Type 2 elements (IEC 61158-3-2:2007, IDT)
MS IEC 61158-3-2:2011
Status : Original
Format : PDF

This Malaysian Standard provides common elements for basic time-critical messaging communications between devices in an automation environment. The term "time-critical" is used to represent the presen ....Read more ce of a time-window, within which one or more specified actions are required to be completed with some defined level of certainty. Failure to complete specified actions within the time window risks failure of the applications requesting the actions, with attendant risk to equipment, plant and possibly human life. Close

RM 75.00

Document will be sent via email



 Add To Cart

Procedure for use in the preparation of maximum lamp outlines (IEC 61126:1992 and its amendment 1 :1996, IDT)
MS IEC 61126:2001 (CONFIRMED:2015)
Status : 1st Confirmation
Format : PDF

This Malaysian Standard deals with the maximum lamp outline drawings and with the procedure to establish and apply them. It details step-by-step procedures which can be used to produce consistent, acc ....Read more urate but simplified drawings which can be called "maximum lamp outlines". Close

RM 105.00

Document will be sent via email



 Add To Cart

TUMBLE DRYERS FOR HOUSEHOLD USE - METHODS FOR MEASURING THE PERFORMANCE (IEC 61121:2005,IDT)
MS IEC 61121:2011
Status : Original
Format : PDF

This Malaysian Standard is applicable to household electric tumble dryers of the automatic and non-automatic type, with or without a cold water supply and incorporating a heating device.