• :  
BM ENG
  • Subscription
  • MS Catalogue
  • MS Pack
  • Purchase History
  • Cart
  • Hi
    !
    • My Profile
    • Portal
    • Log Out

Modal title

Widget settings form goes here

Search Malaysian Standard (MS)
 Advanced Search Search


Biological evaluation of medical devices - Part 9: Framework for identification and quantification of potential degradation products (ISO 10993-9:2009, IDT)
MS ISO 10993-9:2013
Status : Withdrawn
Format : PDF

This Malaysian Standard provides general principles for the systematic evaluation of the potential and observed biodegradation of medical devices and for the design and performance of biodegradation s ....Read more tudies. Information obtained from these studies can be used in the biological evaluation described in the MS ISO 10993 series. This standard considers both non-resorbable and resorbable materials. 
This standard is not applicable to:

a) evaluation of degradation which occurs by purely mechanical processes; methodologies for the production of this type of degradation product are described in specific product standards, where available;

b) leachable components which are not degradation products;

c) medical devices or components that do not contact the patient's body directly or indirectly.
Close

NOT FOR SALE

Please contact us if you are interested to purchase for reference.




Biological evaluation of medical devices - Part 16: Toxicokinetic study design for degradation products and leachables (First revision) (ISO 10993-16:2010, IDT)
MS ISO 10993-16:2011 (CONFIRMED:2015)
Status : 1st Confirmation
Format : PDF

This Malaysian Standard gives principles on how toxicokinetic studies relevant to medical devices should be designed and performed. Annex A describes the considerations for inclusion of toxicokinetic ....Read more studies in the biological evaluation of medical devices. Close

RM 30.00

Document will be sent via email



 Add To Cart

OPHTHALMIC INSTRUMENTS - INDIRECT OPHTHALMOSCOPES (ISO 10943:2006, IDT)
MS ISO 10943:2011
Status : Original
Format : PDF

This Malaysian Standard gives principles on how toxicokinetic studies relevant to medical devices should be designed and performed. Annex A describes the considerations for inclusion of toxicokinetic ....Read more studies in the biological evaluation of medical devices. Close

RM 15.00

Document will be sent via email



 Add To Cart

Ophthalmic instruments - Direct ophthalmoscopes (ISO 10942:2006, IDT)
MS ISO 10942:2010 (CONFIRMED:2015)
Status : 1st Confirmation
Format : PDF

This Malaysian Standard specifies the minimum requirements and test methods for hand-held direct ophthalmoscopes designed for directly observing the eye fundus.

RM 15.00

Document will be sent via email



 Add To Cart

PLASTICS PIPING SYSTEMS FOR INDUSTRIAL APPLICATIONS - POLY(VINYLIDENE FLUORIDE) (PVDF) - SPECIFICATIONS FOR COMPONENTS AND THE SYSTEM (ISO 10931:2005, IDT)
MS ISO 10931:2010
Status : Original
Format : PDF

This Malaysian Standard specifies the characteristics and requirements for components such as pipes, fittings and valves made from poly(vinylidene fluoride) (PVDF), intended to be used for thermoplast ....Read more ics piping systems in the field of industrial applications above-ground. 
It is applicable to PVDF pipes, fittings, valves and ancillary equipment, their joints and to joints with components of other plastics and non-plastics materials, depending on their suitability, intended to be used for the conveyance of liquid and gaseous fluids as well as of solid matters in fluids for industrial applications including

- chemical plants,

- industrial sewerage engineering,

- power engineering (cooling and general purpose water),

- electroplating and pickling plants,

- semiconductor industry,

- agricultural production plants, and

- water treatment.

This Malaysian Standard is applicable to PVDF piping systems for use at temperatures up to 150 °C. However, for applications above 120 °C,
Close

RM 75.00

Document will be sent via email



 Add To Cart

Nanotechnologies - Characterization of single-wall carbon nanotubes using near infrared photoluminescence spectroscopy (ISO/TS 10867:2010, IDT)
MS ISO/TS 10867:2012
Status : Withdrawn
Format : PDF

This Malaysian Standard specifies guidelines for the characterization of single-wall carbon nanotubes (SWCNTs) using near infrared (NIR) photoluminescence (PL) spectroscopy, measurement method for the ....Read more determination of the chiral indices of the semi-conducting SWCNT in a sample and their relative integrated PL intensities and the method can be expanded to estimate relative mass concentrations of semi-conducting SWCNTs in a sample from measured integrated PL intensities and knowledge of their PL cross-sections. Close

NOT FOR SALE

"Please contact us if you are interested to purchase for reference."




STATIONARY SOURCE EMISSIONS - DETERMINATION OF THE MASS CONCENTRATION OF NITROGEN OXIDES - PERFORMANCE CHARACTERISTICS OF AUTOMATED MEASURING SYSTEMS (ISO 10849:1996, IDT)
MS ISO 10849:2011
Status : Original
Format : PDF

This Malaysian Standard specifies the fundamental structure and the most important performance characteristics of automated measuring systems for oxides of nitrogen to be used on stationary source emi ....Read more ssions, for example combustion plants. The procedures to determine the performance characteristics are also specified. Furthermore, it describes methods and equipment to determine NO or NOx, (NO + NO2,) in flue gases including the sampling system and sample gas conditioning system. Dinitrogen monoxide 

(N2O) is not determined by the methods described in this standard. The given performance characteristics refer to the complete measuring system, from sampling to analyser.
Close

RM 45.00

Document will be sent via email



 Add To Cart

STATIONARY SOURCE EMISSIONS - MEASUREMENT OF VELOCITY AND VOLUME FLOWRATE OF GAS STREAMS IN DUCTS (ISO 10780:1994 (2005), IDT)
MS ISO 10780:2009 (CONFIRMED:2019)
Status : Original
Format : PDF

This Malaysian Standard specifies manual methods for determining the velocity and volume flowrate of gas streams in ducts, Stacks and chimneys vented to the atmosphere. lt specifies the use of two typ ....Read more es of Pitot tubes, type L and type S, for determining the velocity and the volume flowrate, and recommends sampling conditions for which each type of Pitot tube is preferred. 
The use of other types of Pitot tubes is permitted in acordance with this Malaysian Standard providing they meet the accuracy requirements in clause 10.

This Malaysian Standard applies to gas streams with essentially constant density, temperature, flowrate and pressure at the sampling Points. lt applies to situations where the Reynolds number of the gas stream as it flows around the Pitot tube is greater than 1,2, the pressure differential across the Pitot tube orifices (ports) is greater than 5 Pa and the Cross-sectional area of the duct at the sampling Point is at least 0,07 m2. lt specifies the technology and ma
Close

RM 45.00

Document will be sent via email



 Add To Cart

Acceptance sampling plans and procedures for the inspection of bulk materials (ISO 10725:2000, IDT)
MS ISO 10725:2004 (CONFIRMED:2023)
Status : 2nd Confirmation
Format : PDF

This Malaysian Standard specifies acceptance sampling plans by the determination of variables and use of acceptance inspection procedures for bulk materials. These sampling plans comply with specific ....Read more operating characteristic curves at reasonable cost. 
This Malaysian Standard is applicable to the inspection where the lot mean of a single quality characteristic is the principal factor in the determination of lot acceptability, but it also gives special procedures for multiple quality characteristics. This Malaysian Standard is applicable to the cases where the values of standard deviations at individual stages of sampling are known or are imprecise.

This Malaysian Standard is applicable to various kinds of bulk materials, but is not always applicable to minerals such as iron ores, coals, crude petroleum, etc., where accurate estimation of the lot mean is more important than the determination of lot acceptability.

For special cases when standard procedures are not always adequate and
Close

RM 135.00

Document will be sent via email



 Add To Cart

WATER QUALITY - DETERMINATION OF THE ACTIVITY CONCENTRATION OF RADIONUCLIDES - METHOD BY HIGH RESOLUTION GAMMA-RAY SPECTROMETRY (FIRST REVISION) (ISO 10703:2007, IDT)
MS ISO 10703:2010 (CONFIRMED 2018)
Status : 1st Revision
Format : PDF

This Malaysian Standard specifies a method for the simultaneous determination of the activity concentration of various radionuclides emitting gamma rays with energies 40 keV < E < 2 MeV in water sampl ....Read more es, by gamma-ray spectrometry using germanium detectors with high energy resolution in combination with a multichannel analyser. 

This Malaysian Standard includes the procedures for energy calibration, determination of the energy dependent sensitivity of the measuring system, the analysis of the spectra and the determination of the activity concentration of the various radionuclides in the sample studied. It is only applicable to homogeneous samples. Samples with activities typically between 1 Bq and 104 Bq can be measured as such, i.e. without dilution or concentration of the sample or special (electronic) devices.

Depending on different factors, such as the energy of the gamma rays and the emission probability per nuclear disintegration, the size and geometry of the sample and the det
Close

RM 45.00

Document will be sent via email



 Add To Cart

  • ‹
  • 1
  • 2
  • ...
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • ...
  • 580
  • 581
  • ›