• :  
BM ENG
  • Subscription
  • MS Catalogue
  • MS Pack
  • Purchase History
  • Cart
  • Hi
    !
    • My Profile
    • Portal
    • Log Out

Modal title

Widget settings form goes here

Search Malaysian Standard (MS)
 Advanced Search Search


PLASTICS - DETERMINATION OF TENSION - TENSION FATIGUE CRACK PROPAGATION -LINEAR ELASTIC FRACTURE MECHANICS(LEFM) APPROACH (ISO 15850:2002, IDT)
MS ISO 15850:2004 (CONFIRMED:2011)
Status : 1st Confirmation
Format : PDF

This standard specifies a method for measuring the propagation of a crack in a notched specimen subjected to a cyclic tensile load varying between a constant positive minimum and a constant positive m ....Read more aximum value. The test results include the crack length as a function of the number of load cycles and the crack length increase rate as a function of the stress intensity factor and energy release rate at the crack tip. The possible occurrence of discontinuities in crack propagation is detected and reported. Close

RM 45.00

Document will be sent via email



 Add To Cart

Condensed aerosol fire extinguishing systems - Requirements and test methods for components and system design, installation and maintenance - General requirements (ISO 15779:2011, MOD)
MS 15779:2015
Status : Original
Format : PDF

This Malaysian Standard specifies requirements and test methods for components and gives recommendations for the design, installation, testing, maintenance and safety of condensed aerosol firefighting ....Read more systems in buildings, plants or other structures, and the characteristics of the extinguishants and types of fire for which they are a suitable extinguishing medium. It covers total flooding systems primarily related to buildings, plant and other specific applications, utilizing electrically non-conducting condensed aerosol fire extinguishants for which there are sufficient data currently available to enable validation of performance characteristics by an appropriate independent authority. Close

RM 120.00

Document will be sent via email



 Add To Cart

PAPER AND BOARD - DETERMINATION OF z-DIRECTIONAL TENSILE STRENGTH (ISO 15754:2009, IDT)
MS ISO 15754:2010 (CONFIRMED:2023)
Status : 1st Confirmation
Format : PDF

This Malaysian Standard specifies a method for the determination of z-directional tensile strength, i.e. the tensile strength in the z-direction. It is applicable to paper and board, but not applicabl ....Read more e to corrugated fibreboard.

For papers, the grammage range can not be stated explicitly, but results for papers having a grammage less than 60 g/m2 shall be treated with caution since the tape may reinforce the paper.

This International Standard does not determine the absolute strength of paper as the measurement is affected by the tape, the pressing conditions and the speed used.
Close

RM 30.00

Document will be sent via email



 Add To Cart

ANIMAL AND VEGETABLE FATS AND OILS - DETERMINATION OF POLYCYCLIC AROMATIC HYDROCARBONS (ISO 15753:2006, IDT)
MS ISO 15753:2007
Status : Original
Format : PDF

This Malaysian Standard describes two methods for the determination of 15 polycyclic aromatic hydrocarbons (PAHs) in animal and vegetable fats and oils.

- a general method, and
- ....Read more a method specific for coconut oil and vegetable oils with short-chain fatty acids.

These methods are not quantitative for the very volatile compounds such as naphthalene, acenaphthene and fluorene. Due to interferences provided by the matrix itself, palm oil and olive pomace oil cannot be analysed using this method.

The quantification limit is 0,2 ?g/kg for almost all compounds analysed, except for fluoranthene and benzo(g,h,i)perylene where the quantification limit is 0,3 ?g/kg, and indeno(1,2,3-c,d)pyrene where the quantification limit is 1 ?g/kg.
Close

RM 45.00

Document will be sent via email



 Add To Cart

ERGONOMICS OF THE THERMAL ENVIRONMENT - COLD WORKPLACES - RISK ASSESSMENT AND MANAGEMENT (ISO 15743:2008, IDT)
MS ISO 15743:2010 (CONFIRMED:2023)
Status : 1st Confirmation
Format : PDF

This Malaysian Standard presents a strategy and practical tools for assessing and managing cold risk in the workplace, and includes;

a) models and methods for cold risk assessment and ....Read more management;
b) a checklist for identifying cold-related problems at work;
c) a model, method and questionnaire intended for use by occupational health care professionals in identifying those individuals with symptoms that increase their cold sensitivity and, with the aid of such identification, offering optimal guidance and instructions for individual cold protection;
d) guidelines on how to apply thermal standards and other validated scientific methods when assessing cold-related risks; and
e) a practical example from cold work.

This Malaysian Standard supports good occupational health and safety (OHS). It is applicable to both indoor and outdoor work situations - indoor work includes work done inside vehicles, outdoor work both inland and offshore work - but is not applicable to diving situatio
Close

RM 60.00

Document will be sent via email



 Add To Cart

FINE CERAMICS (ADVANCED CERAMICS, ADVANCED TECHNICAL CERAMICS) - TEST METHOD FOR FRACTURE TOUGHNESS OF MONOLITHIC CERAMICS AT ROOM TEMPERATURE BY SINGLE EDGE PRECRACKED BEAM (SEPB) METHOD (ISO 15732:2003, IDT)
MS ISO 15732:2011
Status : Original
Format : PDF

This Malaysian Standard describes a test method for the determination of fracture toughness of monolithic ceramic materials at room temperature by the Single Edge Precracked Beam (SEPB) method.
....Read more
This Malaysian Standard is intended for use with monolithic ceramics and whisker- or particulate-reinforced ceramics which are regarded as macroscopically homogeneous. It does not include continuous-fiberreinforced ceramic composites.

This Malaysian Standard is for material development, material comparison, quality assurance,
characterization, reliability and design data generation.

Fracture toughness values determined with other test methods cannot be interchanged with KIpb as defined in this International Standard, and may not be interchangeable with each other.

Values expressed in this Malaysian Standard are in accordance with the International System of Units (SI).
Close

RM 45.00

Document will be sent via email



 Add To Cart

STATIONARY SOURCE EMISSIONS - SAMPLING AND DETERMINATION OF GASEOUS FLUORIDE CONTENT (ISO 15713:2006, IDT)
MS ISO 15713:2009 (CONFIRMED:2023)
Status : 2nd Confirmation
Format : PDF

This Malaysian Standard is applicable to the measurement of the gaseous fluorides that are entrained in gases carried in stacks or ducts. The gaseous fluoride content is expressed as a mass of hydroge ....Read more n fluoride in the stack gas.

This Malaysian Standard is applicable to all stacks emitting gases with fluoride concentrations of below 200 mg/m3. It can be used for higher concentrations, but then the absorption efficiency of the bubblers should be checked before the results can be regarded as valid. The detection limit of the method is estimated as 0,1 mg m?3, based on a sample volume of 0,1 m3. All compounds that are volatile at the filtration temperature and produce soluble fluoride compounds upon reaction with water are measured by this method. The method does not measure fluorocarbons. The concentration of fluoride in the adsorbent solution is then measured using an ion selective electrode. The amount of fluoride measured is then expressed as hydrogen fluoride by convention, though
Close

RM 30.00

Document will be sent via email



 Add To Cart

Cardiovascular implants and artificial organs - Requirements for single-use tubing packs for cardiopulmonary bypass and extracorporeal membrane oxygenation (ECMO) (ISO 15676:2005, IDT)
MS ISO 15676:2011
Status : Original
Format : PDF

This Malaysian Standard specifies requirements for single-use tubing packs for cardiopulmonary bypass and extracorporeal membrane oxygenation (ECMO). This International Standard is applicable to all m ....Read more edical tubing intended for cardiopulmonary bypass (CPB) and/or extracorporeal membrane oxygenation (ECMO), but specific requirements and tests are included for tubing intended for use with peristaltic pumps during (shortterm, i.e. < 6 h) CPB surgery, or (long-term, i.e. > 24 h) ECMO procedures. The sterility and nonpyrogenicity provisions of this standard are applicable to tubing packs labelled as "sterile".

This standard is applicable only to the tubing aspects for multifunctional systems that may have integral components such as blood gas exchangers (oxygenators), reservoirs, blood filters, defoamers, blood pumps, etc.
Close

RM 30.00

Document will be sent via email



 Add To Cart

Cardiovascular implants and artificial organs - Cardiopulmonary bypass systems - Arterial blood line filters (ISO 15675:2009, IDT)
MS ISO 15675:2011
Status : Original
Format : PDF

This Malaysian Standard specifies requirements for sterile, single-use, arterial blood line filters intended to filter and remove emboli, debris, blood clots and other potentially hazardous solid and ....Read more gaseous material from the blood of humans during cardiopulmonary bypass surgery. Close

RM 30.00

Document will be sent via email



 Add To Cart

Cardiovascular implants and artificial organs - Hard-shell cardiotomy/venous reservoir systems (with/without filter) and soft venous reservoir bags (ISO 15674:2009, IDT)
MS ISO 15674:2011
Status : Original
Format : PDF

This Malaysian Standard specifies requirements for sterile, single-use, extracorporeal hard-shell cardiotomy/venous reservoir systems and soft venous reservoir bags intended for use as a blood reservo ....Read more ir during cardiopulmonary bypass (CPB) surgery.

This standard applies only to the blood reservoir aspects for multifunctional systems which can have integral parts such as blood-gas exchangers (oxygenators), blood filters, defoamers, blood pumps, etc.
Close

RM 30.00

Document will be sent via email



 Add To Cart

  • ‹
  • 1
  • 2
  • ...
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • ...
  • 580
  • 581
  • ›