• :  
BM ENG
  • Subscription
  • MS Catalogue
  • MS Pack
  • Purchase History
  • Cart
  • Hi
    !
    • My Profile
    • Portal
    • Log Out

Modal title

Widget settings form goes here

Search Malaysian Standard (MS)
 Advanced Search Search


FINE CERAMICS (ADVANCED CERAMICS, ADVANCED TECHNICAL CERAMICS) - DETERMINATION OF PARTICLE SIZE DISTRIBUTION OF CERAMIC POWDERS BY LASER DIFFRACTION METHOD (ISO 24235:2007, IDT)
MS ISO 24235:2008
Status : Original
Format : PDF

This Malaysian Standard specifies a laser diffraction method for measuring particle size distributions, by means of the detection of angular distributions of the intensity of light scattered by fine-c ....Read more eramic raw powders dispersed in a liquid phase irradiated by a laser beam. A typical size range is 0.1 ?m to 50 ?m. Close

RM 30.00

Document will be sent via email



 Add To Cart

Skin barrier for ostomy aids - Vocabulary (ISO 24214:2006, IDT)
MS ISO 24214:2011
Status : Original
Format : PDF

This Malaysian Standard defines terms dealing with skin barriers for ostomy aids as defined below.

The standard does not cover medical terms or general adhesive terms.

The ....Read more terms do not individually or collectively define or recommend a product of a specific design, style or size. Close

RM 15.00

Document will be sent via email



 Add To Cart

Random sampling and randomization procedures (ISO 24153:2009, IDT) (Published by STANDARDS MALAYSIA in 2012)
MS ISO 24153:2009
Status : Withdrawn
Format : PDF

This Malaysian Standard defines procedures for random sampling and randomization. Several methods are provided, including approaches based on mechanical devices, tables of random numbers, and portable ....Read more computer algorithms.

This Malaysian Standard is applicable whenever a regulation, contract, or other standard requires random sampling or randomization to be used. The methods are applicable to such situations as:

a) acceptance sampling of discrete units presented for inspection in lots,
b) sampling for survey purposes,
c) auditing of quality management system results, and
d) selecting experimental units, allocating treatments to them, and determining evaluation order in the conduct of designed experiments.

Information is also included to facilitate auditing or other external review of random sampling or randomization results where this is required by quality management personnel or regulatory bodies.

This Malaysian Standard does not provide guidance as to the appropriate rand
Close

NOT FOR SALE

Please contact us if you are interested to purchase for reference.




PULPS - DETERMINATION OF WATER RETENTION VALUE (WRV) (ISO 23714:2007, IDT)
MS ISO 23714:2008
Status : Original
Format : PDF

This Malaysian Standard specifies a procedure for the determination of the water retention value (WRV) of all kinds of pulp.

RM 30.00

Document will be sent via email



 Add To Cart

In vitro diagnostic medical devices - Evaluation of stability of in vitro diagnostic reagents (ISO 23640:2011, IDT)
MS ISO 23640:2013 (CONFIRMED:2020)
Status : Original
Format : PDF

This Malaysian Standard is applicable to the stability evaluation of in vitro diagnostic medical devices, including reagents, calibrators, control materials, diluents, buffers and reagent kits, herein ....Read more after called IVD reagents. This standard can also be applied to specimen collection devices that contain substances used to preserve samples or to initiate reactions for further processing of the sample in the collection device.

This Malaysian Standard specifies general requirements for stability evaluation and gives specific requirements for real time and accelerated stability evaluation when generating data in:

- the establishment of IVD reagent shelf life, including transport conditions suitable to ensure that product specifications are maintained;
- the establishment of stability of the IVD reagent in use after the first opening of the primary container;
- the monitoring of stability of IVD reagents already placed on the market;
- the verification of stability specifications af
Close

RM 30.00

Document will be sent via email



 Add To Cart

Assistive products for persons with vision impairments and persons with vision and hearing impairments - Acoustic and tactile signals for pedestrian traffic lights (ISO 23600:2007, IDT)
MS ISO 23600:2011 (CONFIRMED:2022)
Status : 1st Confirmation
Format : PDF

This Malaysian Standard specifies requirements for acoustic and tactile signals for pedestrian traffic lights to assist in safe and independent mobility of persons with vision impairments and persons ....Read more with vision and hearing impairments.

It is applicable to design, installation and operation of acoustic and tactile signals for pedestrian traffic lights.

It is not applicable to electromagnetic compatibility (EMC), electrical safety or operating conditions.
Close

RM 30.00

Document will be sent via email



 Add To Cart

Rubber - General procedures for preparing and conditioning test pieces for physical test methods (First revision) (ISO 23529:2010, IDT)
MS ISO 23529:2011
Status : Withdrawn
Format : PDF

This Malaysian Standard specifies general procedures for the preparation, measurement, marking, storage and conditioning of rubber test pieces for use in physical tests specified in other Malaysian St ....Read more andards, and the preferred conditions to be used during the tests. Special conditions applicable to a particular test or material or simulating a particular climatic environment are not included, nor are special requirements for testing whole products.

This Malaysian Standard also specifies the requirements for the time interval to be observed between forming and testing of rubber test pieces and products. Such requirements are necessary to obtain reproducible test results and to minimize disagreements between customer and supplier.
Close

NOT FOR SALE

Please contact us if you are interested to purchase for reference.




Breathing system filters for anaesthetic and respiratory use - Part 1: Salt test method to assess filtration performance (ISO 23328-1:2003, IDT)
MS ISO 23328-1:2008 (CONFIRMED:2013)
Status : 1st Confirmation
Format : PDF

This Malaysian Standard gives a short-term airborne sodium chloride particle challenge test method for assessing the filtration performance of breathing system filters (BSF) intended for the filtratio ....Read more n of respired gases.

This standard is applicable to BSF used with a clinical breathing system. It is not applicable to other types of filter, e.g. those designed to protect vacuum sources or gas sample lines, to filter compressed gases, or to protect test equipment for physiological respiratory measurements.
Close

RM 30.00

Document will be sent via email



 Add To Cart

Breathing system filters for anaesthetic and respiratory use - Part 2: Non-filtration aspects (ISO 23328-2:2002, IDT)
MS ISO 23328-2:2008 (CONFIRMED:2013)
Status : 1st Confirmation
Format : PDF

This Malaysian Standard specifies requirements for non-filtration aspects of breathing system filters (BSF) intended for anaesthetic and respiratory use, and addresses connection ports, leakage, resis ....Read more tance to flow, packaging, marking and information supplied. The test method is intended for BSF used with a clinical breathing system.

It is not applicable to other types of filter, e.g. those designed to protect vacuum sources or gas sample lines, to filter compressed gases, or to protect test equipment for physiological respiratory measurements.
Close

RM 30.00

Document will be sent via email



 Add To Cart

IMPLANTS FOR SURGERY - IN VITRO EVALUATION FOR APATITE-FORMING ABILITY OF IMPLANT MATERIALS (ISO 23317:2007, IDT)
MS ISO 23317:2010
Status : Original
Format : PDF

This Malaysian Standard describes the method for detecting apatite formed on a surface of a material in simulated body fluid (SBF).

RM 30.00

Document will be sent via email



 Add To Cart

  • ‹
  • 1
  • 2
  • ...
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • ...
  • 580
  • 581
  • ›