ELECTRICAL INSTALLATIONS OF BUILDINGS - PART 7: REQUIREMENTS FOR SPECIAL INSTALLATIONS OR LOCATIONS - SECTION 702: SWIMMING POOLS AND OTHER BASINS (FIRST REVISION) (IEC 60364-7-702:1997, IDT)
MS IEC 60364-7-702:2003
Status : 1st Revision
Format : PDF

The particular requirements of this Section apply to the basins of swimming pools, the basins of fountains and the basins of paddling pools. They also apply to the surrounding zones of all these basin ....Read more s. In these areas, in normal use, the effect of an electric shock is increased by a reduction in body resistance and contact of the body with earth potential. 
The requirements for swimming pools are applicable for paddling pools.

For swimming pools for medical use, special requirements may be necessary.
Close

RM 45.00

Document will be sent via email



 Add To Cart

ELECTRICAL INSTALLATIONS OF BUILDINGS – PART 5-54: SELECTION AND ERECTION OF ELECTRICAL EQUIPMENT: EARTHING ARRANGEMENTS, PROTECTIVE CONDUCTORS AND PROTECTIVE BONDING CONDUCTORS (IEC 60364-5-54:2002, IDT)
MS IEC 60364-5-54:2004
Status : 1st Confirmation
Format : PDF

This Malaysian Standard addresses the earthing arrangements, protective conductors and protective bonding conductors in order to satisfy the safety of the electrical installation.

RM 45.00

Document will be sent via email



 Add To Cart

ELECTRICAL INSTALLATIONS OF BUILDINGS – PART 6-61: VERIFICATION – INITIAL VERIFICATION (IEC 60364-6-61:2001, IDT)
MS IEC 60364-6-61 : 2003
Status : Original
Format : PDF

This Malaysian Standard lays down requirements for the verification, by inspection and testing, of the compliance of the installation with the relevant requirements of other parts of IEC 60364. Criter ....Read more ia for testing are given and tests described. 
This part is concerned only with new installations; it is not concerned with the inspection and testing of existing installations. However, the criteria for inspection and the tests described may be applied, if thought appropriate, to existing installations.
Close

RM 90.00

Document will be sent via email



 Add To Cart

ELECTRICAL INSTALLATIONS OFBUILDINGS: PART 7: REQUIREMENTS FOR SPECIAL INSTALLATIONS OR LOCATIONS -SECTION 703: LOCATIONS CONTAINING SAUNA HEATERS(IEC 60364-7-703:1984, IDT)
MS IEC 60364-7-703:1996 (CONFIRMED:2002)
Status : 1st Confirmation
Format : PDF

The particular requirements of this section apply to locations in which sauna heating equipment according to IEC Publication 335-2.

RM 30.00

Document will be sent via email



 Add To Cart

ELECTRICAL INSTALLATIONS OF BUILDINGS : PART 7: REQUIREMENTS FOR SPECIAL INSTALLATIONS OR LOCATIONS - SECTION 705: ELECTRICAL INSTALLATIONS OF AGRICULTURAL AND HORTICULTURAL PREMISES (IEC 60364-7-705 : 1984, IDT)
MS IEC 60364-7-705:1996 (CONFIRMED:2002)
Status : 1st Confirmation
Format : PDF

The particular requirements of this section apply to all parts of fixed installations of agricultural and horticular premises outdoors and indoors an to locations where livestock are kept (such as sta ....Read more bles, chicken-houses, piggeries, feed-processing locations, lofts and storages for hay, straw and fertilizers). Close

RM 30.00

Document will be sent via email



 Add To Cart

Low-voltage electrical installations - Part 1: Fundamental principles, assessment of general characteristics, definitions (Second revision) (IEC 60364-1:2005, IDT)
MS IEC 60364-1:2007 (CONFIRMED:2015)
Status : 2nd Revision
Format : PDF

This Malaysian Standard gives the rules for the design, erection and verification of electrical installations. The standards are intended to provide for the safety of persons, livestock and property a ....Read more gainst dangers and damage which may arise in the reasonable use of electrical installations and to provide for the proper functioning of those installations. Close

RM 75.00

Document will be sent via email



 Add To Cart

Electrical installations of buildings - Part 7-710: Requirements for special installations or locations - Medical locations (IEC 60364-7-710:2002, IDT)
MS IEC 60364-7-710:2009 (CONFIRMED:2015)
Status : 1st Confirmation
Format : PDF

The Malaysian Standard apply to electrical installations in medical locations so as to ensure safety of patients and medical staff. These requirements, in the main, refer to hospitals, private clinics ....Read more , medical and dental practices, health care centres and dedicated medical rooms in the work place. Close

RM 45.00

Document will be sent via email



 Add To Cart

Electrical installation of buildings - Part 5-51: Selection and erection of electrical equipment - Common rules (Second revision) (IEC 60364-5-51:2005, IDT)
MS IEC 60364-5-51:2007 (CONFIRMED:2015)
Status : 2nd Revision
Format : PDF

The Malaysian Standard deals with the selection of equipment and its erection. It provides common rules for compliance with measures of protection for safety, requirements for proper functioning for i ....Read more ntended use of the installation, and requirements appropriate to the external influences foreseen. Close

RM 75.00

Document will be sent via email



 Add To Cart

ELECTRICAL INSTALLATIONS OF BUILDINGS - PART 7: REQUIREMENTS FOR SPECIAL INSTALLATIONS OR LOCATIONS - SECTION 707: EARTHING REQUIREMENTS FOR THE INSTALLATIONS OF DATA PROCESSING EQUIPMENT(IEC 364-7-707:1984, IDT)
MS IEC 60364-7-707:1996 (CONFIRMED:2002)
Status : 1st Confirmation
Format : PDF

This Malaysian Standard requirements of this section apply to the connection of data processing equipment to the electrical power installation of buildings.

RM 30.00

Document will be sent via email



 Add To Cart

ELECTRICAL INSTALLATIONS OF BUILDINGS : PART 7 : REQUIREMENTS FOR SPECIAL INSTALLATIONS OR LOCATIONS – SECTION 706 : RESTRICTIVE CONDUCTING LOCATIONS(IEC 60364-7-706 : 1983, IDT)
MS IEC 60364-7-706:1996 (CONFIRMED:2002)
Status : 1st Confirmation
Format : PDF

The malaysian standard particular requirements of this section apply to installations for restrictive conducting locations and to the supply to apparatus within these locations.