LUMINAIRES - PART 1: GENERAL REQUIREMENTS AND TESTS (SECOND REVISION) (IEC 60598-1:2003, IDT)
MS IEC 60598-1:2006Status : 2nd Revision
Format : PDF
This Malaysian Standard specifies general requirements for luminaires, incorporating electric light sources for operation from supply voltages up to 1 000 V. The requirements and related tests of this ....Read more
LUMINAIRES – PART 2-11: PARTICULAR REQUIREMENTS – AQUARIUM LUMINAIRES (IEC 60598-2-11:2005, IDT)
MS IEC 60598-2-11:2006Status : Original
Format : PDF
This Malaysian Standard specifies requirements for household aquarium luminaires for use with tungsten filament, tubular fluorescent or other discharge lamps on supply voltages not exceeding 1 000 V.
LUMINAIRES – PART 2-3: PARTICULAR REQUIREMENTS – LUMINAIRES FOR ROAD AND STREET LIGHTING (FIRST REVISION) (IEC 60598-2-3:2002, IDT)
MS IEC 60598-2-3:2006Status : 1st Revision
Format : PDF
This Malaysian Standard specifies requirements for luminaires for road, street lighting and other public outdoor lighting applications; tunnel lighting; column-integrated luminaires with a minimum tot ....Read more
LUMINAIRES - PART 2-8: PARTICULAR REQUIREMENTS - HANDLAMPS (FIRST REVISION) (IEC 60598-2-8:2001, IDT)
MS IEC 60598-2-8:2006Status : 1st Revision
Format : PDF
This Malaysian Standard specifies requirements for handlamps and similar portable luminaires which are held in the hand when used, for use with tungsten filament and tubular fluorescent lamps on suppl ....Read more
LUMINAIRES – PART 2-24: PARTICULAR REQUIREMENTS – LUMINAIRES WITH LIMITED SURFACE TEMPERATURES (IEC 60598-2-24:1997, IDT)
MS IEC 60598-2-24:2006Status : Original
Format : PDF
This Malaysian Standard specifies requirements for luminaires intended for use where the necessity of limited temperature on the outer surface exists, due to the risk of combustible dust accumulating ....Read more
LUMINAIRES - PART 2: PARTICULAR REQUIREMENTS - SECTION 7: PORTABLE LUMINAIRES FOR GARDEN USE (IEC 60598-2-7:1982 and its Amendment 1:1987 and Amendment 2:1994, IDT)
MS IEC 60598-2-7:2003 (CONFIRMED:2011)Status : 1st Confirmation
Format : PDF
This Malaysian Standard specifies requirements for portable pedestal luminaires for use in places such as gardens and for portable luminaires for use in places such as flower beds, for use with tungst ....Read more
LUMINAIRES - PART 2: PARTICULAR REQUIREMENTS - SECTION 2: RECESSED LUMINAIRES
MS IEC 60598-2-2:1998 (CONFIRMED:2011)Status : 1st Confirmation
Format : PDF
This Malaysian Standard specifies requirements for recessed luminaires incorporating electric light sources for operation from supply voltages up to 1 000 V. This Malaysian Standard does not apply to ....Read more
Luminaires - Part 2: Particular requirements section 18: Luminaires for swimming pools and similar applications
MS IEC 60598-2-18:1998 (CONFIRMED:2015)Status : 1st Confirmation
Format : PDF
This Malaysian Standard specifies requirements for fixed luminaires intended for use in the water, or in contact with the water, in, for example, the basins of swimming pools, fountains, paddling pool ....Read more
Luminaires - Part 2: Particular requirements - Section one - Fixed general purpose luminaires
MS IEC 60598-2-1:1997 (CONFIRMED:2015)Status : 1st Confirmation
Format : PDF
This Malaysian Standard specifies requirements for fixed general purpose luminaires for use with tungsten filament, tubular fluorescent and other discharge lamps on supply voltages not exceeding 1 000 ....Read more
Electrical supply track systems for luminaires (First revision) (IEC 60570:2003, IDT)
MS IEC 60570:2006 (CONFIRMED:2015)Status : Withdrawal without replacement
Format : PDF
This Malaysian Standard applies to the following track systems with two or more poles for the connection of luminaires to the electrical supply consisting of, either – a system with a rated voltage ....Read more