• :  
BM ENG
  • Subscription
  • MS Catalogue
  • MS Pack
  • Purchase History
  • Cart
  • Hi
    !
    • My Profile
    • Portal
    • Log Out

Modal title

Widget settings form goes here

Search Malaysian Standard (MS)
 Advanced Search Search


RUBBER, VULCANIZED – DETERMINATION OF CREEP IN COMPRESSION OR SHEAR (ISO 8013:1988, IDT)
MS ISO 8013:2005
Status : Original
Format : PDF

This malaysian Standard specifies a method for the determination of creep in rubber continuously subject to compressive or to shear forces. The Standard ....Read more cannot be used for intermittent deformation of rubber. Close

NOT FOR SALE

"Please contact us if you are interested to purchase for reference."




Mechanical contraceptives - Reusable natural and silicone rubber contraceptive diaphragms - Requirements and tests (ISO 8009:2004, AMD. 1:2012, IDT)
MS ISO 8009:2013
Status : Withdrawn
Format : PDF

This malaysian Standard specifies the minimum requirements and test methods to be used for reusable diaphragms made from natural rubber and silicone rub ....Read more ber. These diaphragms are intended for contraceptive use. 
This malaysian Standard is not applicable to other vaginal contraceptive barriers, such as those known as cervical caps, vaginal sponges and vaginal sheaths.
Close

NOT FOR SALE

Please contact us if you are interested to purchase for reference.




STATIONARY SOURCE EMISSIONS - DETERMINATION OF THE MASS CONCENTRATION OF SULFUR DIOXIDE - PERFORMANCE CHARACTERISTICS OF AUTOMATED MEASURING METHODS (ISO 7935:1992, IDT)
MS ISO 7935:2011
Status : Original
Format : PDF

This malaysian Standard specifies a complete set of values of performance characteristics for automated measuring systems for the continuous measurement ....Read more of the mass concentrations of sulfur dioxide in stationary source emissions. Close

RM 30.00

Document will be sent via email



 Add To Cart

STATIONARY SOURCE EMISSIONS - DETERMINATION OF THE MASS CONCENTRATION OF SULFUR DIOXIDE - HYDROGEN PEROXIDE/BARIUM PERCHLORATE/THORIN METHOD (ISO 7934:1989, AMD. 1:1998, IDT)
MS ISO 7934:2010 (CONFIRMED:2023)
Status : 2nd Confirmation
Format : PDF

This malaysian Standard specifies a hydrogen peroxide/barium perchlorate/Thorin method for the determination of the mass concentration of Sulfur dioxide ....Read more emitted from combustion facilities and technical processes with negligible amounts of Sulfur trioxide and sulfuric acid. lt is applicable from a minimum of 30 mg/m3 sulfur dioxide by reference to sampling periods of normally 30 min. 
At mass concentrations of sulfur dioxide greater than 2 000 mg/m3, the volume of the waste gas under investigation passed through the sampling train is 30 Iitres.

Substances, which, if contained in the waste gas under investigation and thus in the waste gas sample, are known to have an effect on the titration reading, are given in 7.4. Information on performance characteristics is given in 8.2.

At mass concentrations of Sulfur dioxide less than 30 mg/m3, a sampling period greater than that specified in this malaysian Standard is used.

All concentrations are based on dry gas at a temperature of 273,1
Close

RM 30.00

Document will be sent via email



 Add To Cart

STEEL WIRE AND WIRE PRODUCTS FOR FENCES - ZINC- AND ZINC-ALLOY-COATED STEEL BARBED WIRE (ISO 7900:2006, IDT)
MS ISO 7900:2011 (CONFIRMED:2025)
Status : 1st Confirmation
Format : PDF

This malaysian Standard specifies the characteristics of zinc- and zinc-alloy-coated steel barbed wire, with conventional and reverse twist consisting o ....Read more f two stranded line wires, around which the barbs are tightly wound, a twist being imparted between the barbs to restrict their movement. The barbed-wire entanglement has a single line wire, around which the barbs are wound. Close

RM 15.00

Document will be sent via email



 Add To Cart

WATER QUALITY – DETERMINATION OF ELECTRICAL CONDUCTIVITY (ISO 7888:1985, IDT)
MS ISO 7888:2005 (CONFIRMED:2025)
Status : 2nd Confirmation
Format : PDF

This malaysian Standard specifies a method for the measurement of the electrical conductivity of all types of water. Electrical conductivity can be used ....Read more to monitor the quality of surface waters; process waters, and waste waters in water supply and treatment plants. The completeness of analysis for ionic constituents[l 10 31 tan be checked using this method. In some cases absolute values are important, in other cases only relative changes are of concern. For interferences, see clause 9. Close

RM 15.00

Document will be sent via email



 Add To Cart

Sterile hypodermic needles for single use (ISO 7864:1993, IDT)
MS ISO 7864:2011
Status : Original
Format : PDF

This malaysian Standard specifies requirements for sterile hypodermic needles for single use of nominal outside diameters 0.3 mm and 1.2 mm. 
It ....Read more does not apply to dental needles. Close

RM 30.00

Document will be sent via email



 Add To Cart

Iron ores - Determination of arsenic content - Molybdenum blue spectrophotometric method (ISO 7834:1987, IDT)
MS ISO 7834:2004 (CONFIRMED:2013)
Status : 1st Confirmation
Format : PDF

This malaysian Standard specifies a molybdenum blue spectrophotometric method for the determination of the arsenic content of iron ores. 
This me ....Read more thod is applicable to a concentration range of 0,000 1 to 0,l % (mlm) (1 to 1 000 pg/g) of arsenic in natura1 iron ores, and iron ore concentrates and agglomerates including Sinter products. Close

RM 30.00

Document will be sent via email



 Add To Cart

IRON ORES - PREPARATION OF PREDRIED TEST SAMPLES FOR CHEMICAL ANALYSIS (FIRST REVISION) (ISO 7764:2006, IDT)
MS ISO 7764:2011
Status : 1st Revision
Format : PDF

This malaysian Standard specifies a method for the preparation of predried test samples of natural iron ores, and iron ore concentrates and agglomerates ....Read more , including sinter products, which are to be used for the determination of analytical values of constituents on a dry basis. 
The method is not applicable to the following types of ores:

a) processed ores containing metallic iron (direct-reduced iron);
b) natural or processed ores in which the mass fraction of sulfur is higher than 0,2 %;
c) natural or processed ores in which the content of combined water is higher than 2,5 % by mass.

NOTE 1 Alternatively, the loss on ignition may be determined as an estimate of the combined water content.

Where this method is not applicable, ISO 2596:1994, Iron ores — Determination of hygroscopic moisture in analytical samples — Gravimetric and Karl Fischer methods is used.

NOTE 2 A laboratory may elect to use ISO 2596 for all samples to determine the dry sample mass.
Close

RM 15.00

Document will be sent via email



 Add To Cart

ERGONOMICS OF THE THERMAL ENVIRONMENT - ANALYTICAL DETERMINATION AND INTERPRETATION OF THERMAL COMFORT USING CALCULATION OF THE PMV AND PPD INDICES AND LOCAL THERMAL COMFORT CRITERIA (ISO 7730:2005, IDT)
MS ISO 7730:2007
Status : Original
Format : PDF

This malaysian Standard presents methods for predicting the general thermal sensation and degree of discomfort (thermal dissatisfaction) of people expos ....Read more ed to moderate thermal environments. It enables the analytical determination and interpretation of thermal comfort using calculation of PMV (predicted mean vote) and PPD (predicted percentage of dissatisfied) and local thermal comfort criteria, giving the environmental conditions considered acceptable for general thermal comfort as well as those representing local discomfort. It is applicable to healthy men and women exposed to indoor environments where thermal comfort is desirable, but where moderate deviations from thermal comfort occur, in the design of new environments or the assessment of existing ones. 
Although developed specifically for the work environment, it is applicable to other kinds of environment as well. It is intended to be used with reference to ISO/TS 14415:2005, 4.2, when considering persons with special requirement
Close

RM 90.00

Document will be sent via email



 Add To Cart

  • ‹
  • 1
  • 2
  • ...
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • ...
  • 523
  • 524
  • ›