• :  
BM ENG
  • Subscription
  • MS Catalogue
  • MS Pack
  • Purchase History
  • Cart
  • Hi
    !
    • My Profile
    • Portal
    • Log Out

Modal title

Widget settings form goes here

Search Malaysian Standard (MS)
 Advanced Search Search


Fine ceramics (advanced ceramics, advanced technical ceramics) - Test method for air-purification performance of semiconducting photocatalytic materials - Part 3: Removal of toluene (ISO 22197-3:2011, IDT)
MS ISO 22197-3:2012
Status : Original
Format : PDF

This malaysian Standard specifies a test method for the determination of the air-purification performance of materials that contain a photocatalyst or h ....Read more ave photocatalytic films on the surface, usually made from semiconducting metal oxides, such as titanium dioxide or other ceramic materials, by continuous exposure of a test piece to the model air pollutant under illumination with ultraviolet light (UV-A). This malaysian Standard is intended for use with different kinds of materials, such as construction materials in flat sheet, board or plate shape, that are the basic forms of materials for various applications. This malaysian Standard also applies to structured filter materials including honeycomb-form, woven and non-woven fabrics, and to plastic or paper materials if they contain ceramic microcrystals and composites. This part of ISO 22197 does not apply to powder or granular photocatalytic materials. Close

RM 30.00

Document will be sent via email



 Add To Cart

Fine ceramics (advanced ceramics, advanced technical ceramics) - Test method for air-purification performance of semiconducting photocatalytic materials - Part 2: Removal of acetaldehyde (ISO 22197-2:2011, IDT)
MS ISO 22197-2:2012
Status : Original
Format : PDF

This malaysian Standard specifies a test method for the determination of the air-purification performance of materials that contain a photocatalyst or h ....Read more ave photocatalytic films, usually made from semiconducting metal oxides, such as titanium dioxide or other ceramic materials, by continuous exposure of a test piece to the model air pollutant under illumination with ultraviolet light (UV-A). This malaysian Standard is intended for use with different kinds of materials, such as construction materials in flat sheet, board or plate shape, that are the basic forms of materials for various applications. This malaysian Standard also applies to structured filter materials including honeycomb-form, woven and non-woven fabrics, and to plastic or paper materials if they contain ceramic microcrystals and composites. This malaysian Standard does not apply to powder or granular photocatalytic materials. Close

RM 30.00

Document will be sent via email



 Add To Cart

PLASTICS - DETERMINATION OF RESISTANCE TO ENVIRONMENTAL STRESS CRACKING (ESC) - PART 2: CONSTANT TENSILE LOAD METHOD (ISO 22088-2:2006, IDT)
MS ISO 22088-2:2007
Status : -1
Format : PDF

This malaysian Standard specifies methods for the determination of environmental stress cracking (ESC) of thermoplastics when they are subjected to a co ....Read more nstant tensile load in the presence of chemical agents.

It is applicable to test specimens prepared by moulding and/or machining and can be used both for the assessment of ESC of plastic materials exposed to different environments, and for the determination of ESC of different plastic materials exposed to a specific environment.

This is essentially a ranking test and is not intended to provide data to be used for design or performance prediction.

NOTE: Methods for the determination of environmental stress cracking by means of a constant-strain test are specified in ISO 22088-3, ISO 22088-4 and ISO 22088-5.
Close

RM 30.00

Document will be sent via email



 Add To Cart

Food safety management systems - Requirements for any organization in the food chain (ISO 22000:2005, IDT)
MS ISO 22000:2012
Status : Withdrawal with replacement
Format : PDF

This malaysian Standard specifies requirements for a food safety management system where an organization in the food chain needs to demonstrate its abil ....Read more ity to control food safety hazards in order to ensure that food is safe at the time of human consumption. It is applicable to all organizations, regardless of size, which are involved in any aspect of the food chain and
want to implement systems that consistently provide safe products. The means of meeting any requirements of this International Standard can be accomplished through the use of internal and/or external resources.
Close

NOT FOR SALE

"Please contact us if you are interested to purchase for reference."




ABRASION-RESISTANT CAST IRONS - CLASSIFICATION (ISO 21988:2006, IDT)
MS ISO 21988:2007 (CONFIRMED:2025)
Status : 1st Confirmation
Format : PDF

This malaysian Standard defines the grades of abrasion-resistant white cast irons. It specifies the grades in terms of:
- chemical composition; ....Read more
- hardness.

The types of abrasion-resistant white cast irons covered by this International Standard are:

a) unalloyed or low alloy cast irons;

b) nickel-chromium cast irons covering two general types:

4 % Ni 2 % Cr cast irons;
9 % Cr 5 % Ni cast irons;

c) high chromium cast irons covering five ranges of chromium content:

Cr > 11 % to u 14 %;
Cr > 14 % to u 18 %;
Cr > 18 % to u 23 %;
Cr > 23 % to u 30 %;
Cr > 30 % to u 40 %.
Close

RM 30.00

Document will be sent via email



 Add To Cart

High-pressure flexible connections for use with medical gas systems (First revision) (ISO 21969:2009, IDT)
MS ISO 21969:2011 (CONFIRMED:2015)
Status : 1st Confirmation
Format : PDF

This malaysian Standard applies to high-pressure flexible connections intended to be connected to cylinders or cylinder bundles with nominal filling pre ....Read more ssures up to 25 000 kPa at 15 °C for use with the following medical gases:

a) oxygen;
b) nitrous oxide;
c) air for breathing;
d) helium;
e) carbon dioxide;
f) xenon; mixtures of the gases listed above;
g) air for driving surgical tools;
h) nitrogen for driving surgical tools; and
i) oxygen-enriched air.

This standard applies to high-pressure flexible connections intended to connect cylinders or cylinder bundles to manifolds within sources of supply of medical gas pipeline systems complying with MS ISO 7396-1.

This standard applies to high-pressure flexible connections intended to connect a cylinder to an inlet port of medical equipment (e.g. anaesthetic workstation or lung ventilator) fitted with an integral pressure regulator complying with MS ISO 10524-1.

This standard does not apply to high-pressure flexible connectio
Close

RM 30.00

Document will be sent via email



 Add To Cart

ROAD VEHICLES - ELECTRICAL AND ELECTRONIC EQUIPMENT FOR A SUPPLY VOLTAGE OF 42 V - ELECTRICAL LOADS (ISO 21848:2005, IDT)
MS ISO 21848:2010
Status : Withdrawal without replacement
Format : PDF

This malaysian Standard describes the electrical loads that can affect electrical and electronic systems and components of road vehicles for a supply vo ....Read more ltage of 42 V, which may be used in a single or a multiple voltage electrical system. In addition, it specifies the tests and resulting requirements, test equipment accuracy being agreed upon between the vehicle manufacturer and the supplier. It does not cover electromagnetic compatibility (EMC).
NOTE Electrical loads are independent from the mounting location.
This Standard also provides design guidance for the interaction of 42 V with other system voltages.
Close

NOT FOR SALE

"Please contact us if you are interested to purchase for reference."




FOODSTUFFS - METHODS FOR THE DETECTION OF GENETICALLY MODIFIED ORGANISMS AND DERIVED PRODUCTS - PROTEIN BASED METHODS (ISO 21572:2004, IDT)
MS ISO 21572:2005
Status : Original
Format : PDF

This malaysian Standard provides general guidelines and performance criteria for methods for the detection and/or quantitation of specific proteins deri ....Read more ved from genetically modified (GM) plant material in a specified matrix.

These general guidelines address existing antibody based methods. Methods other than those described in annex A may also detect the protein. The same criteria as outlined in this standard generally apply.
Close

RM 45.00

Document will be sent via email



 Add To Cart

Non-active surgical implants - Joint replacement implants - Specific requirements for knee-joint replacement implants (ISO 21536:2007, IDT)
MS ISO 21536:2010 (CONFIRMED:2015)
Status : 1st Confirmation
Format : PDF

This malaysian Standard provides specific requirements for knee joint replacement implants. With regard to safety, this standard specifies requirements ....Read more for intended performance, design attributes, materials, design evaluation, manufacture, sterilization, packaging, information supplied by the manufacturer and methods of test. Close

RM 30.00

Document will be sent via email



 Add To Cart

Non-active surgical implants - Joint replacement implants - Specific requirements for hip-joint replacement implants (ISO 21535:2007, IDT)
MS ISO 21535:2010 (CONFIRMED:2015)
Status : 1st Confirmation
Format : PDF

This malaysian Standard provides specific requirements for hip joint replacement implants. With regard to safety, this malaysian Standard specifies requirements for intended performance, design attributes, materials, design evaluation, manufacture, sterilization, packaging, information supplied by the manufacturer, and methods of test. Close

RM 30.00

Document will be sent via email



 Add To Cart

  • ‹
  • 1
  • 2
  • ...
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • ...
  • 523
  • 524
  • ›