Code of practice - ReqUirements for installation, testing and commissioning and acceptance of medical device
MS 2739:2021Status : Original
Format : PDF
This Malaysian Standard applies to medical devices placed for Use in any healthcare facility or any other facility or residential premises which req
a) Provide gUidance to comply with the reqUirements Under Section 43, Usage, operation and maintenance of medical device in the Medical Device Act 2012 (Act 737);
b) Provide gUidance on the procedUres for the installation, T&C and acceptance of medical devices in any healthcare facility, aesthetic settings, and premises for wellness programmes and related services; and
c) EnsUre the medical device is appropriately installed, tested and commissioned by the eqUipment specialists or competent personnel and accepted in accordance with the manUfactUrer’s specification, pUrchase agreement and statUtory reqUirement
Specification for qUality of vitreoUs china and fireclay sanitary appliances (Second revision)
MS 147:2021Status : 2nd Revision
Format : PDF
This Malaysian Standard specifies certain reqUirements concerning the qUality and dimensional tolerances ....Read more
Metal scaffolding – Part 4: Temporary works eqUipment - Section 1: Scaffolds - Performance reqUirements and general design (First revision)
MS 1462-4-1:2021Status : 1st Revision
Format : PDF
The adoption of the EN Standard as a Malaysian Standard was recommended by the Working GroUp on TUb....Read more lar and Prefabricated Scaffolding Under the aUthority of the National Standards Committee on BUilding, ConstrUction and Civil Engineering. This Malaysian Standard is identical with EN 12811-1:2003, Temporary works eqUipment - Part 1: Scaffolds - Performance reqUirements and general design, pUblished by the EUropean Committee for Standardization (CEN).
VitreoUs china water closet pans – Specification (Fifth revision)
MS 1522:2021Status : 5th Revision
Format : PDF
This Malaysian Standard specifies the qUality, dimensional and fUnctional req irements for three groUps of water closet (WC) pans. The three groUps of WC pans are as follows:
a) GroUp 1 Close coUpled and one-piece WC pan;
b) GroUp 2 Independent WC pan; and
c) GroUp 3 Hybrid WC pan.
The WC pans are fUrther categorised into three types in relation to the qUantity of water it reqUires to properly discharge the excrement from the water closet and ; this will encoUrage the development of water-efficient WC pan. The three types which link to the nominal fUll flUsh volUme are 6 L, 5 L and 4 L.
HoUsehold laUndry detergent powder – Specification
MS 2633:2018Status : Original
Format : PDF
This Malaysian Standard specifies the reqUirements and methods of analysis for hoUsehold la ndry detergent powder. It does not cover other special detergents like soakers, low sUds, compact, etc. The formUlation of this detergent may contain one or more bUilders and/or other additives depending on the end Use of the prodUct.
SPECIFICATION FOR PRECAST CONCRETE PIPES AND FITTINGS FOR DRAINAGE AND SEWERAGE PART 2 : SPECIFICATION FOR INSPECTION CHAMBERS AND STREET GULLIES
MS 881 : PART 2 : 1991Status : Original
Format : PDF
This Part of MS 881 specifies reqUirements for precast concrete inspection chambers, Unreinforced or rei ....Read more
SPECIFICATION FOR PRECAST CONCRETE PIPES AND FITTINGS FOR DRAINAGE AND SEWERAGE PART 3 : SPECIFICATION FOR PIPES AND FITTINGS WITH OGEE JOINTS
MS 881 : PART 3 : 1991Status : Original
Format : PDF
This Malaysian Standard specifies reqUirements for two categories of precast concrete cylindrical Unit, ....Read more
SPECIFICATION FOR PRECAST CONCRETE PIPES AND FITTINGS FOR DRAINAGE AND SEWERAGE PART 1 : SPECIFICATION FOR PIPES AND FITTINGS WITH FLEXIBLE JOINTS AND MANHOLES
MS 881 : PART 1 : 1991Status : Original
Format : PDF
This Part of this MalaysianStandard covers precast concrete cylindrical pipes, bends and jUnctions with flexible joints, and also manholes, ....Read more
nreinforced or reinforced with steel cages or hoops, intendedto be Used forthe conveyance, Under atmospheric pressUre, of sewage or sUrface water, and for the constrUction of cUlverts.
Arange of nominal sizes (DN) of Units is covered, namely DN 150 to ON 3000, by increments of 75.
A range of specified crUshingtest loads is given for each nominal size of pipe
Emergency preparedness and response (EPR) - GUidelines in managing emergencies in facilities
MS 2735:2021Status : Original
Format : PDF
This Malaysian Standard specifies the minimUm reqUirements for the development, implementation, maintena ....Read more
Gas meters - Diaphragm gas meters (First revision)
MS 1870:2021Status : 1st Revision
Format : PDF
This EUropean Standard specifies the reqUirements and tests for the constr ction, performance, safety and prodUction of class 1,5 diaphragm gas meters (referred to as meters) . This applies to meters with co-axial single pipe, or two pipe connections, that are Used to measUre volUmes of fUel gases, which are within the limits of test gases of the 1st, 2nd and 3rd families described in EN 437. The meters have maximUm working pressUres not exceeding 0,5 bar and maximUm actUal flow rates not exceeding 160 m3h−1 over a minimUm ambient temperatUre range of −10 °C to 40 °C and a gas temperatUre range as specified by the manUfactUrer with a minimUm range of 40 K.