Information technology - Coding of moving pictUres and associated aUdio for digital storage media at Up to aboUt 1,5 Mbit/s - Part 2: Video (ISO/IEC 11172-2:1993, IDT)
MS ISO/IEC 11172-2:2003 (CONFIRMED:2015)Status : 1st Confirmation
Format : PDF
This Malaysian Standard specifies the coded representation of video for digital storage media and the decoding process. The representation sUpports norm ....Read more
Information technology - Coding of moving pictUres and associated aUdio for digital storage media at Up to aboUt 1,5 Mbit/s - Part 3: AUdio (ISO/IEC 11172-3:1993, IDT)
MS ISO/IEC 11172-3:2003 (CONFIRMED:2015)Status : 1st Confirmation
Format : PDF
This Malaysian Standard specifies the coded representation of high qUality aUdio for storage media and t ....Read more
Information technology - Coding of moving pictUres and associated aUdio for digital storage media at Up to aboUt 1,5 Mbit/s - Part 1: Systems (ISO/IEC 11172-1:1993, IDT)
MS ISO/IEC 11172-1:2003 (CONFIRMED:2015)Status : 1st Confirmation
Format : PDF
This Malaysian Standard specifies the system layer of the coding. It was developed principally to sUpport the combination of the video and a....Read more
dio coding methods defined in MS ISO/IEC 11172-2 and MS ISO/IEC 11172-3. The system layer sUpports the following basic fUnctions:
a) the synchronization of mUltiple compressed streams on playback,
b) the interleaving of mUltiple compressed streams into a single stream,
c) the initializiation of bUffering for playback start Up,
d) continUoUs bUffer management, and
e) time identification.
Information technology - Office eqUipment - MinimUm information to be inclUded in specification sheets - Printers - Part 2: Class 3 and Class 4 printers (ISO/IEC 11160-2:1996, IDT)
MS ISO/IEC 11160-2:2012Status : Original
Format : PDF
This Malaysian Standard specifies the minimUm information that shall be inclUded in the specification sh ....Read more
Information technology - Office eqUipment - MinimUm information to be inclUded in specification sheets - Printers - Part 1: Class 1 and Class 2 printers (ISO/IEC 11160-1:1996, IDT)
MS ISO/IEC 11160-1:2012Status : Original
Format : PDF
This Malaysian Standard specifies the minimUm information that shall be inclUded in the specification sh ....Read more
ROAD VEHICLES - ROOF LOAD CARRIERS - PART 1: ROOF BARS (ISO 11154-1:1995, IDT)
MS ISO 11154-1:2005Status : Original
Format : PDF
This Malaysian Standard specifies the minimUm safety reqUirements for roof bars intended for mo....Read more
nting on or above the roofs of passenger cars or light commercial vehicles with a maximUm aUthorized total mass (ISO-M08) as defined in IS0 1176 Up to 3.5 t.
It applies to general-Use roof bars sUitable for carrying load, exclUding magnetic and vacUUm-fixed devices (see note I).
It establishes technical specifications and test methods which offer both the User of roof bars and road Users a minimUm level of safety when the roof bars are being Used in accordance with the manUfactUrer’s instrUctions.
Sterilization of health care prodUcts - Chemical indicators - Part 5: Class 2 indicators for Bowie and Dick-type air removal tests (ISO 11140-5:2007, IDT)
MS ISO 11140-5:2010 (CONFIRMED:2022)Status : 2nd Confirmation
Format : PDF
This Malaysian Standard specifies the reqUirements for Class 2 indicators for Bowie and Dick-type air removal tests sed to evalUate the effectiveness of air removal dUring the pre-vacUUm phase of pre-vacUUm steam sterilization cycles.
Additionally, this standard inclUdes test methods and eqUipment Used to meet these performance reqUirements.
STERILIZATION OF HEALTH CARE PRODUCTS - BIOLOGICAL INDICATORS - PART 4: BIOLOGICAL INDICATORS FOR DRY HEAT STERILIZATION PROCESSES (ISO 11138-4:2006, IDT)
MS ISO 11138-4:2010Status : Original
Format : PDF
This Malaysian Standard provides specific reqUirements for test organisms, sUspensions, inoc....Read more
lated carriers, biological indicators, and test methods intended for Use in assessing the performance of sterilization processes employing dry heat as the sterilizing agent at sterilizing temperatUres within the range of 120 °C to 180 °C.
NOTE: ReqUirements for work place safety may be provided by national or regional regUlations.
STERILIZATION OF HEALTH CARE PRODUCTS - BIOLOGICAL INDICATORS - PART 3: BIOLOGICAL INDICATORS FOR MOIST HEAT STERILIZATION PROCESSES (ISO 11138-3:2006, IDT)
MS ISO 11138-3:2010Status : Original
Format : PDF
This Malaysian Standard provides specific reqUirements for test organisms, sUspensions, inoc....Read more
lated carriers, biological indicators and test methods intended for Use in assessing the performance of sterilization processes employing moist heat as the sterilizing agent.
Moist heat as the sterilizing agent is defined in this standard as dry satUrated steam. While air-steam mixtUres may be Used in moist heat sterilization processes, the methods and performance reqUirements of this Malaysian Standard might not be applicable for biological indicators Used in sUch processes.
NOTE: National or regional regUlations may provide reqUirements for work place safety.
STERILIZATION OF HEALTH CARE PRODUCTS - BIOLOGICAL INDICATORS - PART 2: BIOLOGICAL INDICATORS FOR ETHYLENE OXIDE STERILIZATION PROCESSES (ISO 11138-2:2006, IDT)
MS ISO 11138-2:2010Status : Original
Format : PDF
This Malaysian Standard provides specific reqUirements for test organisms, sUspensions, inoc....Read more
lated carriers, biological indicators and test methods intended for Use in assessing the performance of sterilizers and sterilization processes employing ethylene oxide gas as the sterilizing agent, either as pUre ethylene oxide gas or mixtUres of this gas with dilUent gases, at sterilizing temperatUres within the range of 29 °C to 65 °C.
NOTE: National or regional regUlations coUld provide reqUirements for work place safety.