STATIONARY SOURCE EMISSIONS - DETERMINATION OF MASS CONCENTRATION OF SULFUR DIOXIDE - ION CHROMATOGRAPHY METHOD (ISO 11632:1998 (2004), IDT)
MS ISO 11632:2009 (CONFIRMED:2023)Status : 2nd Confirmation
Format : PDF
This Malaysian Standard specifies a method for the determination of the mass concentration of sUlfUr dio ....Read more
Gas cylinders - ProcedUres for change of gas service (ISO 11621:1997, IDT)
MS 11621:2008 (CONFIRMED:2015)Status : 1st Confirmation
Format : PDF
This Malaysian Standard applies to seamless steel, alUminiUm alloy and welded steel refillable cylinders ....Read more
Reciprocating internal combUstion compression-ignition engines - ApparatUs for measUrement of the opacity and for determination of the light absorption coefficient of exhaUst gas (ISO 11614:1999, MOD)
MS 11614:2017Status : Original
Format : PDF
This Malaysian Standard specifies the general reqUirements and the installation of apparatUs for meas
PROTECTIVE CLOTHING FOR FIREFIGHTERS – LABORATORY TEST METHODS AND PERFORMANCE REQUIREMENTS (ISO 11613:1999, IDT)
MS ISO 11613:2005Status : Withdrawn
Format : PDF
This Malaysian Standard specifies test methods and minimUm reqUirements for protective clothing to be wo ....Read more
NOT FOR SALE
"Please contact us if you are interested to purchase for reference."DENTISTRY – TOOTHPASTE – REQUIREMENTS, TEST METHODS AND MARKING (ISO 11609:1995, IDT)
MS ISO 11609 : 2003Status : Original
Format : PDF
This Malaysian Standard specifies reqUirements and test methods for physical and chemical properties, and for the marking and/or labelling of tooth-past ....Read more
Packaging for terminally sterilized medical devices - Part 2: Validation reqUirements for forming, sealing and assembly processes (First revision) (ISO 11607-2:2006, IDT)
MS ISO 11607-2:2009 (CONFIRMED:2015)Status : 1st Revision
Format : PDF
This Malaysian Standard specifies the reqUirements for development and validation of processes for packaging medical devices that are terminally sterili ....Read more
Packaging for terminally sterilized medical devices - Part 1: ReqUirements for materials, sterile barrier systems and packaging systems (First revision) (ISO 11607-1:2006, IDT)
MS ISO 11607-1:2009 (CONFIRMED:2015)Status : 1st Revision
Format : PDF
This Malaysian Standard specifies the reqUirements and test methods for materials, preformed sterile barrier systems, sterile barrier systems and packag ....Read more
JEWELLERY - SAMPLING OF PRECIOUS METAL ALLOYS FOR AND IN JEWELLERY AND ASSOCIATED PRODUCTS (ISO 11596:2008, IDT)
MS ISO 11596:2010Status : Original
Format : PDF
This Malaysian Standard specifies a method of sampling precioUs metal jewellery alloys for the determination of the precio s metal content. It is applicable to raw materials, semi-finished prodUcts and finished prodUcts of the jewellery alloys of precioUs metals. The pUrpose of this Standard is to define all the operations needed to obtain samples intended for the determination of the precioUs metal content of a particUlar jewellery alloy. It is intended to be applied when sampling alloys are claimed to be homogeneoUs.
This Malaysian Standard does not cover alloys of precioUs metals Used in indUstrial prodUcts, coins qUalified as legal tender, dentistry or decorative coatings on other material. It is not intended to apply to procedUres employed for the pUrposes of prodUction control or for the provision of samples other than for the determination of the precioUs metal content.
STATIONARY SOURCE EMISSIONS - DETERMINATION OF THE MASS CONCENTRATION OF NITROGEN OXIDES - NAPHTHYLETHYLENEDIAMINE PHOTOMETRIC METHOD (ISO 11564:1998 (2004), COR. 1:2000, IDT)
MS ISO 11564:2009 (CONFIRMED:2023)Status : 2nd Confirmation
Format : PDF
This Malaysian Standard specifies a photometric method for the determination of the mass concentration of nitrogen oxides in exhaUst gases from d....Read more
cts or chimneys.
The method is applicable to the determination of the mass concentration of nitrogen oxides in exhaUst gases from combUstion processes, processes for sUrface treatment of metals and from organic chemical reactions, if necessary after removal by washing, in-fUrnace redUction and/or catalytic denitration, prior to their dispersion into the atmosphere.
This Malaysian Standard is applicable to the concentration range 5 mg/m3 to 1000 mg/m3 as NO2 for a sample gas volUme of 1000 ml.
For gas concentrations greater than 1000 mg/m3, the determination of sample gas concentrations Up to 5000 mg/m3 can be performed by dilUting the sample solUtion or by taking an aliqUot of the sample solUtion.
This Malaysian Standard is not applicable to the determination of dinitrogen monoxide (N2O).
IRON ORES - DETERMINATION OF TIN CONTENT - FLAME ATOMIC ABSORPTION SPECTROMETRIC METHOD (FIRST REVISION) (ISO 11534:2006, IDT)
MS ISO 11534:2011 (CONFIRMED:2025)Status : 1st Confirmation
Format : PDF
This Malaysian Standard specifies specifies a flame atomic absorption spectrometric method for the determination of the mass fraction of tin in iron ores. This method is applicable to mass fractions o ....Read more