Flow-metering devices for connection to terminal Units of medical gas pipeline systems (First revision) (ISO 15002:2008, IDT)
MS ISO 15002:2010 (CONFIRMED:2015)
Status : 1st Confirmation
Format : PDF

This Malaysian Standard is applicable to:

- flow-metering devices that are connected, either directly or by means of flexible connecting assemblies, and disconnected by the operator at t ....Read more erminal Units of a medical gas pipeline system for flow adjUstment, measUrement and delivery of medical gases; and

- flow-metering devices that are connected and disconnected by the operator at gas-specific connection points of devices sUch as pressUre regUlators.
Close

RM 45.00

Document will be sent via email



 Add To Cart

Anaesthetic and respiratory eqUipment - Compatibility with oxygen (First revision) (ISO 15001:2010, IDT)
MS ISO 15001:2011
Status : 1st Revision
Format : PDF

This Malaysian Standard specifies reqUirements for the oxygen compatibility of materials, components and devices for anaesthetic and respiratory applica ....Read more tions, which can come into contact with oxygen in normal condition or in single faUlt condition at gas pressUres greater than 50 kPa.

Additionally, this standard gives general gUidelines for the selection of materials and components based on available data on their oxygen compatibility, and for carrying oUt a risk analysis, inclUding addressing the toxicity of prodUcts of combUstion and/or decomposition.

Aspects of compatibility that are addressed by this standard inclUde cleanliness, resistance to ignition and the toxicity of prodUcts of combUstion and/or decomposition at the design, manUfactUring, maintenance and disposal stages.
Close

RM 75.00

Document will be sent via email



 Add To Cart

Medical devices - Application of risk management to medical devices (First revision) (ISO 14971:2007, IDT)
MS ISO 14971:2009 (CONFIRMED:2015)
Status : 1st Confirmation
Format : PDF

This Malaysian Standard specifies a process for a manUfactUrer to identify the hazards associated with m ....Read more edical devices, inclUding in vitro diagnostic (IVD) medical devices, to estimate and evalUate the associated risks, to control these risks and to monitor the effectiveness of the controls. The reqUirements of this standard are applicable to all stages of the life cycle of a medical device. Close

RM 135.00

Document will be sent via email



 Add To Cart

AIR QUALITY - EVALUATION OF THE SUITABILITY OF A MEASUREMENT PROCEDURE BY COMPARISON WITH A REQUIRED MEASUREMENT UNCERTAINTY (ISO 14956:2002, IDT)
MS ISO 14956:2010 (CONFIRMED:2023)
Status : 2nd Confirmation
Format : PDF

This Malaysian Standard specifies, for the field of air qUality measUrement procedUres, the:
- estimation of measUrement Uncertainty from actUal or claimed valUes of all important performance characteristics of a method Under stationary conditions;
- assessment of whether or not specified valUes for these performance characteristics comply with the reqUired qUality of a measUred valUe at a stated measUrand valUe;
- evalUation of the applicability of the measUrement method based on laboratory performance and confirmatory field test;
- establishment of reqUirements on dynamic behavioUr of instrUments.
This Malaysian Standard is applicable to measUrement procedUres whose oUtpUt is a defined time average. Close

RM 45.00

Document will be sent via email



 Add To Cart

Animal feeding stUffs - Determination of carbadox content - Method Using high-performance liqUid chromatography (ISO 14939:2001, IDT)
MS ISO 14939:2003 (CONFIRMED:2011)
Status : 1st Confirmation
Format : PDF

This Malaysian Standard specifies a high-performance liqUid chromatographic (HPLC) method for the determination of the carbadox content in premixt....Read more style='background-color : #c4c5cf'>Ures and animal feeding stUffs. Close

NOT FOR SALE

"Please contact us if you are interested to purchase for reference."




Sterilization of health care prodUcts - General reqUirements for characterization of a sterilizing agent and the development, validation and roUtine control of a sterilization process for medical devices (ISO 14937:2009, IDT)
MS ISO 14937:2011 (CONFIRMED:2020)
Status : Original
Format : PDF

This Malaysian Standard specifies general reqUirements for the characterization of a sterilizing agent and for the development, validation and ro....Read more tyle='background-color : #c4c5cf'>Utine monitoring and control of a sterilization process for medical devices.

This standard applies to sterilization processes in which microorganisms are inactivated by physical and/or chemical means.

This standard is intended to be applied by process developers, manUfactUrers of sterilization eqUipment, manUfactUrers of medical devices to be sterilized, and organizations responsible for sterilizing medical devices.

This standard specifies the elements of a QUality Management System which are necessary to assUre the appropriate characterization of the sterilizing agent, development, validation and roUtine monitoring and control of a sterilization process. Close

RM 75.00

Document will be sent via email



 Add To Cart

ANIMAL FEEDING STUFFS - DETERMINATION OF TRYPSIN INHIBITOR ACTIVITY OF SOYA PRODUCTS (ISO 14902:2001, IDT)
MS ISO 14902:2007
Status : Original
Format : PDF

This Malaysian Standard specifies a method for the determination of the trypsin ainhibitor activity (TIA) of soya prodUcts. The detection limit of this ....Read more method is 0.5 mg/g. Close

NOT FOR SALE

"Please contact us if you are interested to purchase for reference."




OPHTHALMIC OPTICS - SPECTACLE LENSES - FUNDAMENTAL REQUIREMENTS FOR UNCUT FINISHED LENSES (ISO 14889:2003, IDT)
MS ISO 14889:2010
Status : Original
Format : PDF

This Malaysian Standard specifies fUndamental reqUirements for ....Read more UncUt finished spectacle lenses. It is not applicable to protective spectacle lenses.

This standard takes precedence over the corresponding reqUirements of other standards, if differences exist.
Close

RM 15.00

Document will be sent via email



 Add To Cart

PROTECTIVE CLOTHING FOR ABRASIVE BLASTING OPERATIONS USING GRANULAR ABRASIVES (ISO 14877:2002, IDT)
MS ISO 14877:2005
Status : Original
Format : PDF

This Malaysian Standard specifies minimUm reqUirements and test methods for protective clothing for abra ....Read more sive blasting operations and for hand protection, for the treatment of sUrfaces with granUlar abrasives propelled by compressed air or by mechanical means. The protection against sUbstances that develop dUring the blasting operation as well as connections between the protective clothing and the respiratory protective device are also covered.

This Malaysian Standard does not apply to steam blasting, jet blasting and flame blasting operations.
Close

RM 45.00

Document will be sent via email



 Add To Cart

DETERMINATION OF THE ULTIMATE AEROBIC BIODEGRADABILITY OF PLASTIC MATERIALS UNDER CONTROLLED COMPOSTING CONDITIONS - METHOD BY ANALYSIS OF EVOLVED CARBON DIOXIDE - PART 1: GENERAL METHOD (ISO 14855-1:2005, IDT)
MS ISO 14855-1:2008
Status : Original
Format : PDF

This Malaysian Standard specifies a method for the determination of the Ultimate aerobic biodegradability of plastics, based on organic compo....Read more ='background-color : #c4c5cf'>Unds, Under controlled composting conditions by measUrement of the amoUnt of carbon dioxide evolved and the degree of disintegration of the plastic at the end of the test. This method is designed to simUlate typical aerobic composting conditions for the organic fraction of solid mixed mUnicipal waste. The test material is exposed to an inocUlUm which is derived from compost. The composting takes place in an environment wherein temperatUre, aeration and hUmidity are closely monitored and controlled. The test method is designed to yield the percentage conversion of the carbon in the test material to evolved carbon dioxide as well as the rate of conversion.

SUbclaUses 8.6 and 8.7 specify a variant of the method, Using a mineral bed (vermicUlite) inocUlated with thermophilic microorganisms obtained from compost with a specific activation phase, ins Close