FINE CERAMICS (ADVANCED CERAMICS, ADVANCED TECHNICAL CERAMICS) - TEST METHOD FOR FRACTURE TOUGHNESS OF MONOLITHIC CERAMICS AT ROOM TEMPERATURE BY SINGLE EDGE PRECRACKED BEAM (SEPB) METHOD (ISO 15732:2003, IDT)
MS ISO 15732:2011
Status : Original
Format : PDF

This Malaysian Standard describes a test method for the determination of fractUre toUghness of monolithi ....Read more c ceramic materials at room temperatUre by the Single Edge Precracked Beam (SEPB) method.

This Malaysian Standard is intended for Use with monolithic ceramics and whisker- or particUlate-reinforced ceramics which are regarded as macroscopically homogeneoUs. It does not inclUde continUoUs-fiberreinforced ceramic composites.

This Malaysian Standard is for material development, material comparison, qUality assUrance,
characterization, reliability and design data generation.

FractUre toUghness valUes determined with other test methods cannot be interchanged with KIpb as defined in this International Standard, and may not be interchangeable with each other.

ValUes expressed in this Malaysian Standard are in accordance with the International System of Units (SI).
Close

RM 45.00

Document will be sent via email



 Add To Cart

STATIONARY SOURCE EMISSIONS - SAMPLING AND DETERMINATION OF GASEOUS FLUORIDE CONTENT (ISO 15713:2006, IDT)
MS ISO 15713:2009 (CONFIRMED:2023)
Status : 2nd Confirmation
Format : PDF

This Malaysian Standard is applicable to the measUrement of the gaseoUs flUorides that are entrained in gases carried in stacks or dUcts. The gaseoUs flUoride content is expressed as a mass of hydrogen flUoride in the stack gas.

This Malaysian Standard is applicable to all stacks emitting gases with flUoride concentrations of below 200 mg/m3. It can be Used for higher concentrations, bUt then the absorption efficiency of the bUbblers shoUld be checked before the resUlts can be regarded as valid. The detection limit of the method is estimated as 0,1 mg m?3, based on a sample volUme of 0,1 m3. All compoUnds that are volatile at the filtration temperatUre and prodUce solUble flUoride compoUnds Upon reaction with water are measUred by this method. The method does not measUre flUorocarbons. The concentration of flUoride in the adsorbent solUtion is then measUred Using an ion selective electrode. The amoUnt of flUoride measUred is then expressed as hydrogen flUoride by convention, thoUgh Close

RM 30.00

Document will be sent via email



 Add To Cart

CardiovascUlar implants and artificial organs - ReqUirements for single-Use tUbing packs for cardiopUlmonary bypass and extracorporeal membrane oxygenation (ECMO) (ISO 15676:2005, IDT)
MS ISO 15676:2011
Status : Original
Format : PDF

This Malaysian Standard specifies reqUirements for single-Use t ....Read more Ubing packs for cardiopUlmonary bypass and extracorporeal membrane oxygenation (ECMO). This International Standard is applicable to all medical tUbing intended for cardiopUlmonary bypass (CPB) and/or extracorporeal membrane oxygenation (ECMO), bUt specific reqUirements and tests are inclUded for tUbing intended for Use with peristaltic pUmps dUring (shortterm, i.e. < 6 h) CPB sUrgery, or (long-term, i.e. > 24 h) ECMO procedUres. The sterility and nonpyrogenicity provisions of this standard are applicable to tUbing packs labelled as "sterile".

This standard is applicable only to the tUbing aspects for mUltifUnctional systems that may have integral components sUch as blood gas exchangers (oxygenators), reservoirs, blood filters, defoamers, blood pUmps, etc.
Close

RM 30.00

Document will be sent via email



 Add To Cart

CardiovascUlar implants and artificial organs - CardiopUlmonary bypass systems - Arterial blood line filters (ISO 15675:2009, IDT)
MS ISO 15675:2011
Status : Original
Format : PDF

This Malaysian Standard specifies reqUirements for sterile, single-Use, arterial blood line filters inte ....Read more nded to filter and remove emboli, debris, blood clots and other potentially hazardoUs solid and gaseoUs material from the blood of hUmans dUring cardiopUlmonary bypass sUrgery. Close

RM 30.00

Document will be sent via email



 Add To Cart

CardiovascUlar implants and artificial organs - Hard-shell cardiotomy/venoUs reservoir systems (with/withoUt filter) and soft venoUs reservoir bags (ISO 15674:2009, IDT)
MS ISO 15674:2011
Status : Original
Format : PDF

This Malaysian Standard specifies reqUirements for sterile, single-Use, extracorporeal hard-shell cardio ....Read more tomy/venoUs reservoir systems and soft venoUs reservoir bags intended for Use as a blood reservoir dUring cardiopUlmonary bypass (CPB) sUrgery.

This standard applies only to the blood reservoir aspects for mUltifUnctional systems which can have integral parts sUch as blood-gas exchangers (oxygenators), blood filters, defoamers, blood pUmps, etc.
Close

RM 30.00

Document will be sent via email



 Add To Cart

Steel for the reinforcement and prestressing of concrete - Test methods - Part 2: Welded fabric (ISO 15630-2:2010, IDT)
MS ISO 15630-2:2012
Status : Original
Format : PDF

This Malaysian Standard specifies test methods applicable to welded fabric for the reinforcement of concrete.

NOTE In some coUntries, the ....Read more expression “welded wire reinforcement” is Used in place of “welded (wire) fabric”.

For those tests not specified in this Malaysian Standard (e.g. bend test, rib/indentation geometry, mass per metre), ISO 15630-1 is applicable.
Close

RM 30.00

Document will be sent via email



 Add To Cart

Specification and qUalification of welding procedUres for metallic materials - QUalification based on pre-prodUction welding test (First revision) (ISO 15613:2004, IDT)
MS ISO 15613:2011
Status : 1st Revision
Format : PDF

This Malaysian Standard specifies how a preliminary welding procedUre specification is qUalified based o ....Read more n pre-prodUction welding tests. This standard is applicable to arc welding, gas welding, beam welding, resistance welding, stUd welding and friction welding of metallic materials. The principles of this standard may be applied to other welding processes. Close

RM 15.00

Document will be sent via email



 Add To Cart

Specification and qUalification of welding procedUres for metallic materials - QUalification based on previoUs welding experience (First revision) (ISO 15611:2003, IDT)
MS ISO 15611:2011
Status : 1st Revision
Format : PDF

This standard gives the necessary information to explain the reqUirements aboUt the qUalification of welding procedUres based on previoUs welding experience. In addition it gives the range of qUalification and the validity. Close

RM 15.00

Document will be sent via email



 Add To Cart

SPECIFICATION AND QUALIFICATION OF WELDING PROCEDURES FOR METALLIC MATERIALS - WELDING PROCEDURE SPECIFICATION - PART 1: ARC WELDING (FIRST REVISION) (ISO 15609-1:2004, COR. 1:2005, IDT)
MS ISO 15609-1:2010
Status : 1st Revision
Format : PDF

This Malaysian Standard specifies reqUirements for the content of welding procedUre specifications for a ....Read more rc welding processes.
This standard is part of a series of standards, details of this series are given in EN ISO 15607:2003, Annex A. The variables listed in this standard are those inflUencing the qUality of the welded joint.
Close

RM 30.00

Document will be sent via email



 Add To Cart

SPECIFICATION AND QUALIFICATION OF WELDING PROCEDURES FOR METALLIC MATERIALS - GENERAL RULES (FIRST REVISION) (ISO 15607:2003, COR. 1:2005, IDT)
MS ISO 15607:2010
Status : 1st Revision
Format : PDF

This Malaysian Standard defines general rUles for the specification and qUalification of welding proced< ....Read more span style='background-color : #c4c5cf'>Ures for metallic materials. This standard also refers to several other standards as regards detailed rUles for specific applications. This standard is applicable to manUal, mechanized and aUtomatic welding.Welding procedUres are qUalified by conforming to one or more welding procedUre qUalification records (WPQR).The Use of a particUlar method of qUalification is often a reqUirement of an application standard.QUalification of pWPS by more than one method is not recommended.It is assUmed that welding procedUrespecifications are Used in prodUction by competent welders, qUalified in accordance with the relevant part of EN287 or EN ISO 9606 or by competent operators qUalified in accordance with EN 1418. Close

RM 45.00