• :  
BM ENG
  • Subscription
  • MS Catalogue
  • MS Pack
  • Purchase History
  • Cart
  • Hi
    !
    • My Profile
    • Portal
    • Log Out

Modal title

Widget settings form goes here

Search Malaysian Standard (MS)
 Advanced Search Search


Indoor, ambient and workplace air - Sampling and analysis of volatile organic compoUnds by sorbent tUbe/thermal desorption/capillary gas chromatography - Part 2: DiffUsive sampling
MS ISO 16017-2:2008 (CONFIRMED:2023)
Status : 2nd Confirmation
Format : PDF

This Malaysian Standard gives general gUidance for the sampling and analysis of volatile organic compoUn ....Read more ds (VOCs) in air. It is applicable to indoor, ambient and workplace air.

This Malaysian Standard is applicable to a wide range of VOCs, inclUding hydrocarbons, halogenated hydrocarbons, esters, glycol ethers, ketones and alcohols. A nUmber of sorbents1) are recommended for the sampling of these VOCs, each sorbent having a different range of applicability. Very polar compoUnds generally reqUire derivatisation; very low boiling compoUnds are only partially retained by the sorbents and can only be estimated qUalitatively. Semi-volatile compoUnds are fUlly retained by the sorbents, bUt may only be partially recovered.
Close

RM 75.00

Document will be sent via email



 Add To Cart

Indoor, ambient and workplace air - Sampling and analysis of volatile organic compoUnds by sorbent tUbe/thermal desorption/capillary gas chromatography - Part1:PUmped sampling (ISO 16017-1:2000, IDT)
MS ISO 16017-1:2008 (CONFIRMED:2023)
Status : 2nd Confirmation
Format : PDF

This Malaysian Standard gives general gUidance for the sampling and analysis of volatile organic compoUn ....Read more ds(VOCs)in air. It is applicable to ambient, indoor and workplace atmospheres and the assessment of emissions from materials in small-or fUll-scale test chambers.

This Malaysian Standard is appropriate for a wide range of VOCs, inclUding hydrocarbons, halogenated hydro-carbons, esters, glycolethers, ketones and alcohols. A nUmber of sorbents are recommended for the sampling of these VOCs, each sorbent having a different range of applicability. Very polar compoUnds will generally reqUire derivatization, very low boiling compoUnds will only be partially retained by the sorbents, depending on ambient temperatUre, and can only be estimated qUalitatively. Semi-volatile compoUnds will be fUlly retained by the sorbents, bUt may only be partially recovered. CompoUnds for which this part of MS ISO 16017 has been tested are given in tables.

This Malaysian Standard may be applicable to com
Close

RM 60.00

Document will be sent via email



 Add To Cart

PLASTICS – DETERMINATION OF AVERAGE MOLECULAR MASS AND MOLECULAR MASS DISTRIBUTION OF POLYMERS USING SIZE-EXCLUSION CHROMATOGRAPHY -PART 4: HIGH-TEMPERATURE METHOD (ISO 16014-4:2003, IDT)
MS ISO 16014-4:2004
Status : Withdrawn
Format : PDF

This Malaysian Standard specifies a method for determining the average molecUlar mass and the molecUlar ....Read more mass distribUtion of polymers by size-exclUsion chromatography (SEC) Using an organic elUent at temperatUres between 60 °C and 180 °C. The average molecUlar mass and the molecUlar mass distribUtion are calcUlated from a calibration cUrve constrUcted Using polymer standards. Therefore, this test method is classified as a relative method. Close

NOT FOR SALE

"Please contact us if you are interested to purchase for reference."




PLASTICS – DETERMINATION OF AVERAGE MOLECULAR MASS AND MOLECULAR MASS DISTRIBUTION OF POLYMERS USING SIZE-EXCLUSION CHROMATOGRAPHY -PART 3: LOW-TEMPERATURE METHOD (ISO 16014-3:2003, IDT)
MS ISO 16014-3:2004
Status : Withdrawn
Format : PDF

This Malaysian Standard specifies a method for determining the average molecUlar mass and the molecUlar ....Read more mass distribUtion of polymers by size-exclUsion chromatography (SEC) Using an organic elUent at a temperatUre lower than 60 °C. The average molecUlar mass and the molecUlar mass distribUtion are calcUlated from a calibration cUrve constrUcted Using polymer standards. Therefore, this test method is classified as a relative method. Close

NOT FOR SALE

"Please contact us if you are interested to purchase for reference."




PLASTICS – DETERMINATION OF AVERAGE MOLECULAR MASS AND MOLECULAR MASS DISTRIBUTION OF POLYMERS USING SIZE-EXCLUSION CHROMATOGRAPHY -PART 2: UNIVERSAL CALIBRATION METHOD (ISO 16014-2:2003, IDT)
MS ISO 16014-2:2004
Status : Withdrawn
Format : PDF

This Malaysian Standard specifies a method for determining the average molecUlar mass and the molecUlar ....Read more mass distribUtion of polymers Using size-exclUsion chromatography (SEC). The average molecUlar mass and the molecUlar mass distribUtion are calcUlated Using a Universal calibration cUrve instead of the conventional calibration cUrve. The concept of the Universal calibration method is based on a relationship by which the retention time in SEC depends on the size of the polymer molecUle (the hydrodynamic volUme) or on the prodUct of the intrinsic viscosity [?] and the molecUlar mass M. Many polymers classified as random-coil polymers (regardless of their chemical strUctUre, degree of branching, composition or tacticity) have been experimentally confirmed as following this relationship. The Universal calibration cUrve is constrUcted by plotting the logarithm of [?]M versUs the elUtion time t or elUtion volUme V Using polymer standards sUch as polystyrene with narrow molecUlar mass distr Close

NOT FOR SALE

"Please contact us if you are interested to purchase for reference."




PLASTICS – DETERMINATION OF AVERAGE MOLECULAR MASS AND MOLECULAR MASS DISTRIBUTION OF POLYMERS USING SIZE-EXCLUSION CHROMATOGRAPHY - PART 1: GENERAL PRINCIPLES (ISO 16014-1:2003, IDT)
MS ISO 16014-1:2004
Status : Withdrawn
Format : PDF

This Malaysian Standard specifies a general method for determining the average molecUlar mass and the molecU....Read more pan>lar mass distribUtion of polymers Using size-exclUsion chromatography (SEC). The average molecUlar mass and the molecUlar mass distribUtion are calcUlated from a calibration cUrve constrUcted Using polymer standards. Close

NOT FOR SALE

"Please contact us if you are interested to purchase for reference."




PLASTICS – DETERMINATION OF LINEAR DIMENSIONS OF TEST SPECIMENS (ISO 16012:2004 AND TECHNICAL CORRIGENDUM 1:2004, IDT)
MS ISO 16012:2007
Status : Withdrawn
Format : PDF

This Malaysian Standard specifies measUring eqUipment and proced....Read more >Ures for the determination of the linear dimensions of solid plastics test specimens. Close

NOT FOR SALE

"Please contact us if you are interested to purchase for reference."




Indoor air - Part 2: Sampling strategy for formaldehyde (ISO 16000-2:2004, IDT)
MS ISO 16000-2:2008 (CONFIRMED:2023)
Status : 2nd Confirmation
Format : PDF

This Malaysian Standard is intended as an aid to planning formaldehyde indoor pollUtion measUrements. In ....Read more the case of indoor air measUrements1) , the carefUl planning of sampling and the entire measUrement strategy are of particUlar significance, since the resUlt of the measUrement can have far-reaching conseqUences, for example, with regard to the need for remedial action or the sUccess of sUch an action. Close

RM 45.00

Document will be sent via email



 Add To Cart

Indoor air - Part 6: Determination of volatile organic compoUnds in indoor and test chamber air by active sampling on Tenax TA sorbent, thermal desorption and gas chromatography Using MS or MS-FID (First revision) (ISO 16000-6:2011, IDT)
MS ISO 16000-6:2015
Status : 1st Revision
Format : PDF

This Malaysian Standard specifies a method for determination of volatile organic compoUnds (VOCs) in indoor air and in air sampled for the determination ....Read more of the emission of VOCs from bUilding prodUcts or materials and other prodUcts Used in indoor environments Using test chambers and test cells. The method Uses Tenax TA sorbent with sUbseqUent thermal desorption (TD) and gas chromatographic (GC) analysis employing a capillary colUmn or colUmns and a flame ionization detector (FID) and/or a mass spectrometric (MS) detector.

The method is applicable to the measUrement of non-polar and slightly polar VOCs at concentrations ranging from sUb-micrograms per cUbic metre to several milligrams per cUbic metre. Using the principles specified in this method, some very volatile compoUnds (VVOC) and semi-volatile organic compoUnds (SVOC) can also be analysed (see Annex D).
Close

RM 60.00

Document will be sent via email



 Add To Cart

Indoor air - Part 5: Sampling strategy for volatile organic compoUnds (VOCs) (ISO 16000-5:2005, IDT)
MS ISO 16000-5:2008 (CONFIRMED:2023)
Status : 2nd Confirmation
Format : PDF

This Malaysian Standard is intended as an aid to planning volatile organic compoUnd (VOC) indoor pollUti ....Read more on measUrements. In the case of indoor air measUrements, the carefUl planning of sampling and the entire measUrement strategy are of particUlar significance since the resUlt of the measUrement may have far-reaching conseqUences, for example, with regard to the need for remedial action or the sUccess of sUch an action.

An inappropriate measUrement strategy may contribUte to the complete Uncertainty of the measUrement resUlt in a larger extent than the measUrement procedUre itself.

This Malaysian Standard Uses the definition for indoor environment defined in MS ISO 16000-1.
Close

RM 45.00

Document will be sent via email



 Add To Cart

  • ‹
  • 1
  • 2
  • ...
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • ...
  • 572
  • 573
  • ›