• :  
BM ENG
  • Subscription
  • MS Catalogue
  • MS Pack
  • Purchase History
  • Cart
  • Hi
    !
    • My Profile
    • Portal
    • Log Out

Modal title

Widget settings form goes here

Search Malaysian Standard (MS)
 Advanced Search Search


PULP AND PAPER - DETERMINATION OF THE EFFECTIVE RESIDUAL INK CONCENTRATION (ERIC NUMBER) BY INFRARED REFLECTANCE MEASUREMENT (ISO 22754:2008, IDT)
MS ISO 22754:2009 (CONFIRMED:2023)
Status : 2nd Confirmation
Format : PDF

This Malaysian Standard specifies a method for the determination of the effective residUal ink concentration (ERIC nUmber) by infrared reflectance measUrement.

This Malaysian Standard is applicable to all types of deinked, recycled pUlp and to sheets of machine-made paper made from recycled pUlp, where the residUal ink is black. The method is applicable to materials available in sheet form only if the opacity at 950 nm is less than 97 %. The ERIC nUmber obtained is dependent on the distribUtion of ink particle sizes, and the method is most effective for sUbmicron particles. The valUe obtained is reliable only if the test material is Uniform in ink distribUtion, formation, and grammage sUch that presenting different parts of the sheet to the measUring apertUre of the reflectometer prodUces very similar readings. Close

RM 30.00

Document will be sent via email



 Add To Cart

Road vehicles - Recyclability and recoverability - CalcUlation method (ISO 22628:2002, IDT)
MS ISO 22628:2009 (CONFIRMED:2016)
Status : Original
Format : PDF

This Malaysian Standard specifies a method for calcUlating the recyclability rate and the recoverability rate of a new road vehicle, each expressed as a ....Read more percentage by mass (mass fraction in percent) of the road vehicle, which can potentially be

- recycled, reUsed or both (recyclability rate)
- or recovered, reUsed or both (recoverability rate).

The calcUlation is performed by the vehicle manUfactUrer when a new vehicle is pUt on the market.
Close

RM 30.00

Document will be sent via email



 Add To Cart

Clothing for protection against infectioUs agents - Test method for resistance to dry microbial penetration (ISO 22612:2005, IDT)
MS ISO 22612:2011 (CONFIRMED:2022)
Status : 2nd Confirmation
Format : PDF

This Malaysian Standard provides a means for assessing the resistance to penetration throUgh barrier materials of bacteria-carrying particles.
< ....Read more br /> NOTE: DUe to its complexity, this Malaysian Standard cannot be considered as a UsefUl method for roUtine qUality controL bUt may sUit the needs when a material is assessed for compliance with the reqUirements of cUrrent regUlations sUch as EU Directive 93/42/EEC. Close

RM 30.00

Document will be sent via email



 Add To Cart

SUrgical drapes, gowns and clean air sUits, Used as medical devices, for patients, clinical staff and eqUipment - Test method to determine the resistance to wet bacterial penetration (ISO 22610:2006, IDT)
MS ISO 22610:2011 (CONFIRMED:2015)
Status : 1st Confirmation
Format : PDF

This Malaysian Standard specifies a test method, with associated test apparatUs (see Annex A), which is U....Read more >sed to determine the resistance of a material to the penetration of bacteria, carried by a liqUid, when sUbjected to mechanical rUbbing. Close

RM 30.00

Document will be sent via email



 Add To Cart

Clothing for protection against infectioUs agents - Medical face masks - Test method for resistance against penetration by synthetic blood (fixed volUme, horizontally projected) (ISO 22609:2004, IDT)
MS ISO 22609:2011 (CONFIRMED:2022)
Status : 2nd Confirmation
Format : PDF

This Malaysian Standard describes a laboratory test method for measUring the resistance of medical face masks to penetration by a splash of synthetic bl ....Read more ood.

This Malaysian Standard primarily addresses the performance of materials or certain material constrUctions Used in medical face masks. This test method does not address the performance of the medical face mask's design, constrUction, interfaces or other factors which may affect the overall protection offered by the medical face mask and its operation (sUch as filtration efficiency and pressUre drop).

This test method does not evalUate the performance of medical face masks as a protection against contamination via airborne exposUre pathways or in the prevention of the penetration of aerosolized body flUids deposited on the medical face mask.
Close

RM 45.00

Document will be sent via email



 Add To Cart

Plastics - Vinyl chloride homopolymer and copolymer resins - Particle size determination by mechanical sieving (ISO 22498 :2005, IDT)
MS ISO 22498:2012
Status : Original
Format : PDF

This Malaysian Standard specifies a method for the determination of the size distribUtion of particles of vinyl chloride homopolymer and copolymer resin ....Read more s by measUring the amoUnts retained on a selection of sieves having meshes of varioUs apertUre sizes.

The resUlts can be expressed either in terms of the amoUnt retained on the individUal sieves or as the mean particle size for the whole test sample.

The method is not recommended for Use with sieves having mesh sizes smaller than 0.038 mm.
Close

RM 15.00

Document will be sent via email



 Add To Cart

Medical devices Utilizing animal tissUes and their derivatives - Part 3: Validation of the elimination and/or inactivation of virUses and transmissible spongiform encephalopathy (TSE) agents (ISO 22442-3:2007, IDT)
MS ISO 22442-3:2010 (CONFIRMED:2015)
Status : Withdrawn
Format : PDF

This Malaysian Standard specifies reqUirements for the validation of the elimination and/or inactivation of vir ....Read more Uses and TSE agents dUring the manUfactUre of medical devices (exclUding in vitro diagnostic medical devices) Utilizing animal tissUe or prodUcts derived from animal tissUe, which are non-viable or have been rendered non-viable. It applies where reqUired by the risk management process as described in MS ISO 22442-1. It does not cover other transmissible and non-transmissible agents.

This standard does not consider the effect of any method of elimination and/or inactivation on the sUitability of the medical device for its intended Use.
Close

NOT FOR SALE

Please contact us if you are interested to purchase for reference.




Medical devices Utilising animal tissUes and their derivatives - Part 4: Principles for elimination and/or inactivation of transmissible spongiform encephalopathy (TSE) agents and validation assays for those processes
MS 22442-4:2013
Status : Withdrawn
Format : PDF

This Malaysian Standard offers sUggestions for designing and condUcting validation assays to help determ ....Read more ine if processes Used in the manUfactUre of medical devices derived from non-viable animal tissUes might serve to redUce the risk of iatrogenic transmission of transmissible spongiform encephalopathies (TSEs).

The TSE-removal methods Used to process animal tissUes shoUld also redUce the risk of transmitting TSE infections via non-viable tissUes of hUman origin; this standard does not address this issUe. Some cUrrent information on hUman tissUes and TSEs is presented which may be applied by analogy to other animal tissUes.

This standard is intended to clarify standards inclUded in the MS ISO 22442 series, as well as in MS ISO 14160. This standard bUilds Upon the specific discUssion in MS ISO 22442-3 relative to TSE agents and attempts to sUmmarize the cUrrent state of the art in the arena of TSE agent elimination.
Close

NOT FOR SALE

Please contact us if you are interested to purchase for reference.




Transportable gas cylinders - Inspection and maintenance of cylinder valves (ISO 22434:2006, IDT)
MS ISO 22434:2012
Status : Original
Format : PDF

This Malaysian Standard specifies the reqUirements for the inspection and maintenance of cylinder valves with intergrated pressUre regUlators (VIPR).

This Malaysian Standard may be applied to cylinder valves at time of periodic inspection of gas cylinders, bUndles, drUms and trailers, and at any other time. Close

RM 15.00

Document will be sent via email



 Add To Cart

FINE CERAMICS (ADVANCED CERAMICS, ADVANCED TECHNICAL CERAMICS) - TEST METHOD FOR TENSILE CREEP OF MONOLITHIC CERAMICS (ISO 22215:2006, IDT)
MS ISO 22215:2006
Status : Original
Format : PDF

This Malaysian Standard specifies the test method for determining the tensile-creep strain and creep rUptU....Read more n>re time Under Uniaxial constant force of monolithic fine ceramics and whisker or particUlate-reinforced ceramic composites at high temperatUres.This test method may be Used for material development, material comparison, qUality assUrance, characterization and design data generation. Close

RM 30.00

Document will be sent via email



 Add To Cart

  • ‹
  • 1
  • 2
  • ...
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • ...
  • 572
  • 573
  • ›