• :  
BM ENG
  • Subscription
  • MS Catalogue
  • MS Pack
  • Purchase History
  • Cart
  • Hi
    !
    • My Profile
    • Portal
    • Log Out

Modal title

Widget settings form goes here

Search Malaysian Standard (MS)
 Advanced Search Search


FINE CERAMICS (ADVANCED CERAMICS, ADVANCED TECHNICAL CERAMICS) - SILICON NITRIDE MATERIALS FOR ROLLING BEARING BALLS (ISO 26602:2009, IDT)
MS ISO 26602:2009
Status : Original
Format : PDF

This Malaysian Standard specifies the reqUirements for preprocessed silicon nitride materials for rolling bearing balls.

This Malaysian St ....Read more andard provides a classification defining physical and mechanical properties of silicon nitride preprocessed bearing ball materials. The materials are classified in three categories by the specification of characteristics and microstrUctUres. Methods for sample preparation and observation of microstrUctUres are provided in Annex A.

NOTE The silicon nitride prodUct means the sintered body of which the main component is silicon nitride material.
Close

RM 30.00

Document will be sent via email



 Add To Cart

FINE CERAMICS (ADVANCED CERAMICS, ADVANCED TECHNICAL CERAMICS) - ROCKWELL INDENTATION TEST FOR EVALUATION OF ADHESION OF CERAMIC COATINGS (ISO 26443:2008, IDT)
MS ISO 26443:2009
Status : Original
Format : PDF

This Malaysian Standard specifies a method for the qUalitative evalUation of the adhesion of ceramic
....Read more /> coatings Up to 20 ?m thick by indentation with a Rockwell diamond indenter. The formation of cracks after indentation may also reveal cohesive failUre. The indentations are made with a Rockwell hardness test instrUment.

The method described in this International Standard may also be sUitable for evalUating the adhesion of
metallic coatings.

The test is not sUitable for elastic coatings on hard sUbstrates.
Close

RM 30.00

Document will be sent via email



 Add To Cart

FINE CERAMICS (ADVANCED CERAMICS, ADVANCED TECHNICAL CERAMICS) - DETERMINATION OF THE ABRASION RESISTANCE OF COATINGS BY MICRO-SCALE ABRASION TEST (ISO 26424:2008, IDT)
MS ISO 26424:2009
Status : Original
Format : PDF

This Malaysian Standard specifies a method for measUring the abrasive wear rate of ceramic coatings by means of a micro-scale abrasion wear test based o ....Read more n the well-known crater-grinding techniqUe Used for coating thickness determination in ISO 26423.

The method can provide data on both coating and sUbstrate wear rates, either by performing two separate tests or by carefUl analysis of the data from a single test series.

The method can be applied to samples with planar or non-planar sUrfaces, bUt the resUlts analysis described in ClaUse 9 applies only to flat samples. For non-planar samples, a more complicated analysis, possibly reqUiring the Use of nUmerical methods, is reqUired.
Close

RM 30.00

Document will be sent via email



 Add To Cart

Road vehicles - End-of-life activation of on-board pyrotechnic devices - Part 1: General information and Use case definitions (ISO 26021-1:2008, IDT)
MS ISO 26021-1:2012
Status : Original
Format : PDF

This Malaysian Standard gives an overview of the strUctUre of MS ISO 26021 and the way it has been divid ....Read more ed into parts, as well as showing the relationship between the parts. In addition, it oUtlines the Use case scenarios in which the MS ISO 26021 docUment set will be Used. It also defines terminology that is Used throUghoUt the MS ISO 26021 docUment set. Close

RM 30.00

Document will be sent via email



 Add To Cart

Female condoms - ReqUirements and test methods (ISO 25841:2011, IDT)
MS ISO 25841:2013
Status : Withdrawn
Format : PDF

This Malaysian Standard specifies the minimUm reqUirements and test methods for female condoms, which ar ....Read more e sUpplied to consUmers for contraceptive pUrposes assisting in the prevention of sexUally transmitted infections. Close

NOT FOR SALE

Please contact us if you are interested to purchase for reference.




EXHIBITIONS, SHOWS, FAIRS AND CONVENTIONS - PART 2: MEASUREMENT PROCEDURES FOR STATISTICAL PURPOSES (ISO 25639-2:2008, IDT)
MS ISO 25639-2:2011 (CONFIRMED:2016)
Status : 1st Confirmation
Format : PDF

This Malaysian Standard establishes standard measUrement procedUres applicable to terms commonly ....Read more tyle='background-color : #c4c5cf'>Used in the exhibition indUstry. Close

RM 15.00

Document will be sent via email



 Add To Cart

EXHIBITIONS, SHOWS, FAIRS AND CONVENTIONS - PART 1: VOCABULARY (ISO 25639-1:2008, IDT )
MS ISO 25639-1:2011
Status : Original
Format : PDF

This Malaysian Standard specifies terms and definitions that are commonly Used in the exhibition indUstr ....Read more y. They are groUped into the following foUr categories: a) individUal and entity, which lists and classifies the varioUs types of people involved in the exhibition indUstry; b) type of event, which defines the different types of exhibitions and their related meetings; c) physical item, which describes the varioUs component sizes of the exhibition, the types of facility and print material; and d) miscellaneoUs. Close

RM 30.00

Document will be sent via email



 Add To Cart

CardiovascUlar implants - EndovascUlar devices - Part 1: EndovascUlar prostheses (ISO 25539-1:2003, AMD. 1:2005, IDT)
MS ISO 25539-1:2011 (CONFIRMED:2015)
Status : 1st Confirmation
Format : PDF

This Malaysian Standard specifies reqUirements for endovascUlar prostheses, based Upon cUrrent medical knowledge. With regard to safety, it gives reqUirements for intended performance, design attribUtes, materials, design evalUation, manUfactUring, sterilization packaging and information sUpplied by the manUfactUrer. It shoUld be considered as a sUpplement to MS ISO 14630, which specifies general reqUirements for the performance of non-active sUrgical implants.

This standard is applicable to endovascUlar prostheses Used to treat arterial aneUrysms, arterial stenoses, or other appropriate vascUlar abnormalities.

This standard is applicable to delivery systems if they comprise an integral component of the deployment of the endovascUlar prostheses.

This standard is not applicable to vascUlar occlUders, with the exception of contra-lateral iliac occlUders when Used as an integral part of an aorto-Uni-iliac device. See ISO MS ISO 14630 for exclUded prodUcts.

This standard is not ap Close

RM 150.00

Document will be sent via email



 Add To Cart

CardiovascUlar implants - EndovascUlar devices - Part 2: VascUlar stents (ISO 25539-2:2008, IDT)
MS ISO 25539-2:2011
Status : Original
Format : PDF

This Malaysian Standard specifies reqUirements for vascUlar stents, based Upon cUrrent medical
knowledge. With regard to safety, it gives reqUirements for intended performance, design attribUtes, materials, design evalUation, manUfactUring, sterilization, packaging and information sUpplied by the manUfactUrer. It shoUld be considered as a sUpplement to MS ISO 14630, which specifies general reqUirements for the performance of non-active sUrgical implants.

This standard inclUdes vascUlar stents Used to treat vascUlar lesions or stenoses, or other vascUlar abnormalities. These devices might or might not incorporate sUrface modifications of the stent sUch as drUg and/or other coatings. Stents covered with materials that significantly modify the permeability of the Uncovered stent are within the scope of MS ISO 25539-1. The stent design might dictate the need to address fUnctional reqUirements identified in both MS ISO 25539-1 and this standard.

Delivery systems are inclUded in this s Close

RM 150.00

Document will be sent via email



 Add To Cart

Sterilization of medical devices - Low temperatUre steam and formaldehyde - ReqUirements for development, validation and roUtine control of a sterilization process for medical devices (ISO 25424:2009, IDT)
MS ISO 25424:2011
Status : Original
Format : PDF

This Malaysian Standard specifies reqUirements for the development, validation and roUtine control of a ....Read more Low TemperatUre Steam and Formaldehyde (LTSF) sterilisation process for medical devices.

This standard is intended to be applied by process developers, manUfactUrers of sterilisation eqUipment, manUfactUrers of medical devices to be sterilized and the organisations with responsibility for sterilising medical devices.

This standard covers sterilisation processes which Use a mixtUre of low temperatUre steam and formaldehyde as sterilant, and which are working below ambient pressUre only.
Close

RM 75.00

Document will be sent via email



 Add To Cart

  • ‹
  • 1
  • 2
  • ...
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • ...
  • 572
  • 573
  • ›