• :  
BM ENG
  • Subscription
  • MS Catalogue
  • MS Pack
  • Purchase History
  • Cart
  • Hi
    !
    • My Profile
    • Portal
    • Log Out

Modal title

Widget settings form goes here

Search Malaysian Standard (MS)
 Advanced Search Search


Rotating electrical machines - Part 2-1: Standard methods for determining losses and efficiency from tests (exclUding machines for traction vehicles) (IEC 60034-2-1:2007, IDT)
MS IEC 60034-2-1:2014
Status : Withdrawal without replacement
Format : PDF

This Malaysian Standard is intended to establish methods of determining efficiencies from tests, and also to specify methods of obtaining specific losses.

This Malaysian Standard appli ....Read more es to d.c. machines and to a.c. synchronoUs and indUction machines of all sizes within the scope of MS IEC 60034-1. Close

NOT FOR SALE

"Please contact us if you are interested to purchase for reference."




SAFETY OF MACHINERY – PRESSURE-SENSITIVE PROTECTIVE DEVICES – PART 1: GENERAL PRINCIPLES FOR DESIGN AND TESTING OF PRESSURE-SENSITIVE MATS AND PRESSURE-SENSITIVE FLOORS (ISO 13856-1:2001, IDT)
MS ISO 13856-1:2003
Status : Withdrawn
Format : PDF

This part of ISO 13856 specifies reqUirements for pressUre-sensitive mats and floors normally act....Read more tyle='background-color : #c4c5cf'>Uated by the feet,
for Use as safety devices to protect persons from dangeroUs machinery. The minimUm safety reqUirements for the
performance, marking and docUmentation are given.
It covers pressUre-sensitive mats and floors, regardless of type of energy Used, e.g. electrical, hydraUlic, pneUmatic
or mechanical.
This part of ISO 13856 covers mats and floors designed to detect:
a) persons weighing more than 35 kg;
b) and persons (e.g. children) weighing more than 20 kg.
The detection of persons weighing less than 20 kg is not covered by this part of ISO 13856.
This part of ISO 13856 does not specify the dimensions or the configUration of the effective sensing area of
pressUre-sensitive mat(s) or floor(s) in relation to any particUlar application. Close

NOT FOR SALE

Please contact us if you are interested to purchase for reference.




Rotating electrical machines - Part 4: Methods for determining synchronoUs machine qUantities from tests (First revision) (IEC 60034-4:2008, IDT)
MS IEC 60034-4:2014
Status : Withdrawal without replacement
Format : PDF

This Malaysian Standard applies to three-phase synchronoUs machines of 1 kVA rating and larger with rated freqU ....Read more ency of not greater than 500 Hz and not less than 10 Hz.

Most of the methods are intended to be Used for machines having an excitation winding with slip-rings and brUshes for their sUpply. SynchronoUs machines with brUshless excitation reqUire special effort for some of the tests. For machines with permanent magnet excitation, there is a limited applicability of the described tests, and special precaUtions have to be taken
against irreversible demagnetisation.

ExclUded are axial-field machines and special synchronoUs machines sUch as indUctor type machines and transversal flUx machines.

It is not intended that this standard be interpreted as reqUiring any or all of the tests described therein on any given machine. The particUlar tests to be carried oUt shall be sUbject to agreement between manUfactUrer and cUstomer.
Close

NOT FOR SALE

"Please contact us if you are interested to purchase for reference."




Rotating electrical machines - Part 3: Specific reqUirements for synchronoUs generators driven by steam tUrbines or combUstion gas tUrbines (First revision) (IEC 60034-3:2007, IDT)
MS IEC 60034-3:2014
Status : Withdrawal without replacement
Format : PDF

This Malaysian Standard applies to three-phase synchronoUs generators, having rated oUtpUts of 10 MVA and above driven by steam tUrbines or combUstion gas tUrbines. It sUpplements the basic reqUirements for rotating machines given in MS IEC 60034-1.

Common reqUirements are prescribed together with specific reqUirements for air, for hydrogen or for liqUid cooled synchronoUs generators.

This part of Malaysian Standard also gives the precaUtions to be taken when Using hydrogen cooled generators inclUding:

–- rotating exciters driven by synchronoUs generators;
- aUxiliary eqUipment needed for operating the generators;
–- parts of the bUilding where hydrogen might accUmUlate. Close

NOT FOR SALE

"Please contact us if you are interested to purchase for reference."




Rotating electrical machines - Part 7: Classification of types of constrUction, moUnting arrangements and terminal box position (IM Code) (IEC 60034-7:2001, IDT)
MS IEC 60034-7:2006 (CONFIRMED:2013)
Status : Withdrawal without replacement
Format : PDF

This Malaysian Standard specifies the IM Code, a classification of types of constrUction, moUnting arran ....Read more gements and the terminal box position of rotating electrical machines. Close

NOT FOR SALE

"Please contact us if you are interested to purchase for reference."




Rotating electrical machines - Part 6: Methods of cooling (IC Code) (IEC 60034-6:1991, IDT)
MS IEC 60034-6:2006 (CONFIRMED:2013)
Status : Withdrawal without replacement
Format : PDF

This Malaysian Standard identifies circUit arrangements and movement methods of the coolant. It classifies methods of cooling and gives a designation sy ....Read more stem for them. Complete and simplified designations are defined. Close

NOT FOR SALE

"Please contact us if you are interested to purchase for reference."




ROTATING ELECTRICAL MACHINES - PART 26: EFFECTS OF UNBALANCED VOLTAGES ON THE PERFORMANCE OF THREE-PHASE CAGE INDUCTION MOTORS (IEC 60034-26:2006, IDT)
MS IEC 60034-26:2010
Status : Withdrawal without replacement
Format : PDF

This Malaysian Standard describes the effects of Unbalanced voltages on the performance of three-phase cage ind ....Read more Uction motors. Close

NOT FOR SALE

"Please contact us if you are interested to purchase for reference."




Rotating electrical machines - Part 11: Thermal protection (IEC 60034-11:2004, IDT)
MS IEC 60034-11:2007 (CONFIRMED:2015)
Status : Withdrawal without replacement
Format : PDF

This Malaysian Standard specifies reqUirements relating to the Use of thermal protectors and thermal det ....Read more ectors incorporated into the stator windings or placed in other sUitable positions in indUction machines in order to protect them against serioUs damage dUe to thermal overloads. It applies to machines manUfactUred in accordance with IEC 60034-12 with the voltage limits specified in IEC 60034-12. The protection of bearings and other mechanical parts is not inclUded.

NOTE 1 AlthoUgh temperatUre valUes given in this standard are higher than those specified in IEC 60034-1, they are not in conflict.

NOTE 2 Additional reqUirements may apply to particUlar motor types sUch as those Used in hoUsehold appliances, or for motors Used in explosive atmospheres.
Close

NOT FOR SALE

"Please contact us if you are interested to purchase for reference."




Rotating electrical machines - Part 16: Excitation systems for synchronoUs machines - Chapter 2: Models for power system stUdies (IEC/TS 60034-16-2:1991, IDT)
MS IEC/TS 60034-16-2:2007 (CONFIRMED:2015)
Status : Withdrawal without replacement
Format : PDF

This report recommends modelling gUidelines and appropriate models for excitation systems for Use in pow ....Read more er system stability stUdies and inclUdes a nomenclatUre defining the parameters and variables Used. Close

NOT FOR SALE

"Please contact us if you are interested to purchase for reference."




Rotating electrical machines - Part 18-22: FUnctional evalUation of insUlation systems - Test procedUres for wire-woUnd windings - Classification of changes and insUlation component sUbstitUtions (IEC 60034-18-22:2001, IDT)
MS IEC 60034-18-22:2007 (CONFIRMED:2015)
Status : Withdrawal without replacement
Format : PDF

This Malaysian Standard specifies test procedUres for the thermal evalUation and classification of chang ....Read more es and insUlation component sUbstitUtion in insUlation systems Used or proposed for Use in a proven insUlation system Used in wire-woUnd windings. The test procedUres are comparative in that the performance of a candidate system is compared to that of a reference system which has previoUsly been proved by experience or has been evalUated by one of the procedUres given in MS IEC 60034-18-21 and to which the change or sUbstitUtion is intended. Close

NOT FOR SALE

"Please contact us if you are interested to purchase for reference."




  • ‹
  • 1
  • 2
  • ...
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • ...
  • 572
  • 573
  • ›