Switches for household and similar fixed electrical installations - Part 2-4: Particular requirements - Isolating switches (IEC 60669-2-4:2004, IDT)
MS IEC 60669-2-4:2012
Status : Original
Format : PDF

This Malaysian Standard applies to manually operated general purpose isolating switches with a rated voltage not exceeding 440 V and a rated current not exceeding 125 A, intended for household and sim ....Read more ilar fixed electrical installations, either indoors or outdoors. Close

RM 60.00

Document will be sent via email



 Add To Cart

Switches for household and similar fixed electrical installations - Part 2-2: Particular requirements - Electromagnetic remote-control switches (RCS) (First revision) (IEC 60669-2-2:2006, IDT)
MS IEC 60669-2-2:2012
Status : 1st Revision
Format : PDF

This Malaysian Standard applies to electromagnetic remote-control switches (hereinafter referred to as RCS) with a rated voltage not exceeding 440 V and a rated current not exceeding 63 A, intended fo ....Read more r household and similar fixed electrical installations, either indoors or outdoors. The RCS coil may or may not be permanently energized. Electronic RCS are within the scope of IEC 60669-2-1. RCS including only passive components such as resistors, capacitors, PTC and NTC components and printed wiring boards are not considered to be electronic RCS. Close

RM 30.00

Document will be sent via email



 Add To Cart

Switches for household and similar fixed electrical installations - Part 1: General requirements (First Revision) (IEC 60669-1:2007, IDT)
MS IEC 60669-1:2012
Status : 1st Revision
Format : PDF

This Malaysian Standard applies to manually operated general purpose switches, for a.c. only with a rated voltage not exceeding 440 V and a rated current not exceeding 63 A, intended for household and ....Read more similar fixed electrical installations, either indoors or outdoors. For switches provided with screwless terminals the rated current is limited to 16 A. Switches covered by this standard are intended for the control in normal use of:

a) a circuit for a tungsten filament lamp load; or
b) a circuit for a fluorescent lamp load (including electronic ballast); or
c) a circuit for a substantially resistive load with a power factor not less than 0,95; or
d) a monophase circuit for motor load with a rated current up to 10 A and a power factor not
less than 0,6; or
e) a combination of these.
Close

RM 150.00

Document will be sent via email



 Add To Cart

Switches for household and similar fixed electrical installations - Part 2-1: Particular requirements - Electronic switches (First Revision) (IEC 60669-2-1:2009, IDT)
MS IEC 60669-2-1:2012
Status : 1st Revision
Format : PDF

This Malaysian Standard applies to electronic switches and to associated electronic extension units for household and similar fixed electrical installations either indoors or outdoors. It applies to ....Read more electronic switches for a.c. only, for the operation of lamp circuits and the control of the brightness of lamps (dimmers) as well as the control of the speed of motors (for example, those used in ventilating fans) and for other purposes (for example, heating controls), with a rated voltage not exceeding 250 V and a rated current not exceeding 16 A.

The operation and/or control as mentioned above are performed by a person via an actuating member, a sensing surface or a sensing unit, by means of touch, proximity, turn, optical, acoustic, thermal or any other influence.

This standard also applies to general purpose electronic switches with included automatic
functions where the operation and/or the control is initiated by a change of a physical quantity,
for example light, temperature,
Close

RM 75.00

Document will be sent via email



 Add To Cart

SWITCHES FOR HOUSEHOLD AND SIMILAR FIXED ELECTRICAL INSTALLATIONS – PART 2-1: PARTICULAR REQUIREMENTS –ELECTRONIC SWITCHES (IEC 60669-2-1:2002, IDT)
MS IEC 60669-2-1:2004
Status : 1st Revision
Format : PDF

This standard applies to electronic switches and to associated electronic extension units for household and similar fixed electrical installations either indoors or outdoors. It applies to electronic ....Read more switches for a.c. only, for the operation of lamp circuits and the control of the brightness of lamps (dimmers) as well as the control of the speed of motors (for example, those used in ventilating fans) and for other purposes (for example, heating controls),with a rated voltage not exceeding 250 V and a rated current not exceeding 16 A.

The operation and control as mentioned above are performed by a person via an actuating member, a sensing surface or a sensing unit, by means of touch, proximity, turn, optical,acoustic, thermal or any other influence.

This standard also applies to electronic switches where the operation or control is made by physical means, for example, light, wind velocity, presence of persons, etc.
Close

RM 135.00

Document will be sent via email



 Add To Cart

Insulation coordination for equipment within low-voltage systems - Part 3: Use of coating, potting or moulding for protection against pollution (IEC 60664-3:2010, IDT)
MS IEC 60664-3:2014
Status : Original
Format : PDF

This Malaysian Standard applies to assemblies protected against pollution by the use of coating, potting or moulding, thus allowing a reduction of clearance and creepage distances as described in Part ....Read more 1 or Part 5. This standard describes the requirements and test procedures for two methods of protection:
 - type 1 protection improves the microenvironment of the parts under the protection;
- type 2 protection is considered to be similar to solid insulation
Close

RM 45.00

Document will be sent via email



 Add To Cart

Insulation coordination for equipment within low-voltage systems - Part 4: Consideration of high-frequency voltage stress (IEC 60664-4:2005, IDT)
MS IEC 60664-4:2014
Status : Original
Format : PDF

This Malaysian Standard deals with basic, supplementary and reinforced insulation subjected to high-frequency voltage stress within low-voltage equipment. The dimensioning values directly apply for ba ....Read more sic insulation; for reinforced insulation additional requirements apply according to Part 1. It is applicable for the dimensioning of clearances, creepage distances and solid insulation stressed by any type of periodic voltages with a fundamental frequency above 30 kHz and up to 10 MHz. Close

RM 105.00

Document will be sent via email



 Add To Cart

Insulation coordination for equipment within low-voltage systems - Part 5: Comprehensive method for determining clearances and creepage distances equal to or less than 2 mm (IEC 60664-5:2007, IDT)
MS IEC 60664-5:2014
Status : Original
Format : PDF

This Malaysian Standard specifies the dimensioning of clearances and creepage distances for spacings equal to or less than 2 mm for printed wiring board and equivalent constructions, where the clearan ....Read more ce and the creepage distance are identical and are along the surface of solid insulation. The dimensioning in this standard is more precise than that provided by IEC 60664-1. However, if the precision provided by this standard is not required, IEC 60664-1 may be applied instead.
This standard is based on the following criteria for dimensioning: - minimum clearances independent of the micro-environment; - minimum creepage distances for pollution degrees 1, 2 and 3 to avoid failure due to tracking; - minimum creepage distances to avoid flashover across the insulating surface
Close

RM 75.00

Document will be sent via email



 Add To Cart

Insulation coordination for equipment within low-voltage systems - Part 1: Principles, requirements and tests (IEC 60664-1:2007, IDT)
MS IEC 60664-1:2014
Status : Original
Format : PDF

This Malaysian Standard deals with insulation coordination for equipment within low-voltage systems. It applies to equipment for use up to 2 000 m above sea level having a rated voltage up to a.c. 1 0 ....Read more 00 V with rated frequencies up to 30 kHz, or a rated voltage up to d.c. 1 500 V. It specifies the requirements for clearances, creepage distances and solid insulation for equipment based upon their performance criteria. It includes methods of electric testing with respect to insulation coordination.

The minimum clearances specified in this standard do not apply where ionized gases occur. Special requirements for such situations may be specified at the discretion of the relevant technical committee.
Close

RM 120.00

Document will be sent via email



 Add To Cart

Insulation coordination for equipment within low-voltage systems - Part 2-1: Application guide - Explanation of the application of the MS IEC 60664 series, dimensioning examples and dielectric testing
MS 60664-2-1:2015
Status : Original
Format : PDF

This Malaysian Standard, provides an application guide for manufacturers specifying dimensioning requirements for products in accordance with the MS IEC 60664 series. 
The significant items for ....Read more consideration are as follows:

a) nominal system voltage(s) or rated insulation voltage(s);
b) overvoltage category of the products (OV cat);
c) any type of overvoltages;
d) frequency of the voltage;
e) characteristics of the solid insulating material; and

f) pollution degree and humidity levels.
Close

RM 105.00