BM ENG
  • Home
  • Service
  • International Standard
  • FAQ
  • Publish
  • signin
  •  Cart ()
Search Malaysian Standard (MS)
 Advanced Search Search




Low-voltage switchgear and controlgear - Part 6-1: Multiple function equipment - Transfer switching equipment (IEC 60947-6-1:2005, IDT)
MS IEC 60947-6-1:2012
Status : Original
Format : PDF

This Malaysian Standard is applies to transfer switching equipment (TSE) to be used in power systems with interruption of the supply to the load during transfer, the rated voltage of which does not ex ....Read more ceed 1 000 V a.c. or 1 500 V d.c. Close

RM 75.00

Document will be sent via email



 Add To Cart

Low-voltage switchgear and controlgear - Part 5-4: Control circuit devices and switching elements - Method of assessing the performance of low-energy contacts - Special tests (IEC 60947-5-4:2002, IDT)
MS IEC 60947-5-4:2012
Status : Original
Format : PDF

This Malaysian Standard applies to separable contacts used in the utilization area considered, such as switching elements for control circuits

RM 45.00

Document will be sent via email



 Add To Cart

LOW-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 4-3: CONTACTORS AND MOTOR-STARTERS - AC SEMICONDUCTOR CONTROLLERS AND CONTACTORS FOR NON-MOTOR LOADS (IEC 60947-4-3:2007, IDT)
MS IEC 60947-4-3:2010
Status : Original
Format : PDF

This Malaysian Standard applies to a.c. semiconductor non-motor load controllers and 

RM 135.00

Document will be sent via email



 Add To Cart

Low-voltage switchgear and controlgear - Part 3: Switches, disconnectors, switch-disconnectors and fuse-combination units (Second revision) (IEC 60947-3:2008, IDT)
MS IEC 60947-3:2010 (CONFIRMED:2015)
Status : 2nd Revision
Format : PDF

This Malaysian Standard applies to switches, disconnectors, switch-disconnectors and fuse-combination units to be used in distribution circuits and motor circuits of which the rated voltage does not e ....Read more xceed 1 000 V a.c. or 1 500 V d.c.  Close

RM 105.00

Document will be sent via email



 Add To Cart

LOW-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 2: CIRCUIT-BREAKERS (SECOND REVISION) (IEC 60947-2:2009, IDT)
MS IEC 60947-2:2010
Status : 2nd Revision
Format : PDF

This standard applies to circuit-breakers, the main contacts of which are intended to be 
It applies whatever the rated currents, the method of construction or the proposed applications
....Read more of the circuit-breakers may be.

The requirements for circuit-breakers which are also intended to provide earth-leakage
protection are contained in Annex B.

The additional requirements for circuit-breakers with electronic over-current protection are
contained in Annex F.

The additional requirements for circuit-breakers for IT systems are contained in Annex H.
The requirements and test methods for electromagnetic compatibility of circuit-breakers are
contained in Annex J.

The requirements for circuit-breakers not fulfilling the requirements for over-current protection
are contained in Annex L.

The requirements for modular residual current devices (without integral current breaking
device) are contained in Annex M.

The requirements and test methods for electromagnetic compatibility of ci
Close

RM 345.00

Document will be sent via email



 Add To Cart

LOW-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 4-2: CONTACTORS AND MOTOR-STARTERS - AC SEMICONDUCTOR MOTOR CONTROLLERS AND STARTERS (FIRST REVISION) (IEC 60947-4-2:2007, IDT)
MS IEC 60947-4-2:2010
Status : 1st Revision
Format : PDF

This Malaysian standard applies to controllers and starters, which may include a series mechanical 
This standard characterizes controllers and starters with and without bypass means.
....Read more r /> Controllers and starters dealt with in this standard are not normally designed to interrupt
short-circuit currents. Therefore, suitable short-circuit protection (see 8.2.5) should form part
of the installation, but not necessarily of the controller or starter.

In this context, this standard gives requirements for controllers and starters associated with
separate short-circuit protective devices.

This standard does not apply to:
– continuous operation of a.c. motors at motor speeds other than the normal speed;
– semiconductor equipment, including semiconductor contactors (see 2.2.13 of IEC 60947-1)
controlling non-motor loads;
– electronic a.c. power controllers covered by IEC 60146.

Contactors, overload relays and control circuit devices used in controllers and starters should
comply with
Close

RM 165.00

Document will be sent via email



 Add To Cart

LOW-VOLTAGE SWITCHGEAR AND CONTOLGEAR - PART 2: CIRCUIT-BREAKERS (IEC 60947-2:2003, IDT)
MS IEC 60947-2:2007
Status : Original
Format : PDF

This Malaysian Standard applies to circuit-breakers, the main contacts of which are intended to be connected to circuits, the rated voltage of which does not exceed 1 000 V a.c. or 1 500 V d.c.; it a ....Read more lso contains additional requirements for integrally fused circuit-breakers.
It applies whatever the rated currents, the method of construction or the proposed applications
of the circuit-breakers may be.

The requirements for circuit-breakers which are also intended to provide earth-leakage
protection are contained in annex B.

The additional requirements for circuit-breakers with electronic over-current protection are
contained in annex F.

The additional requirements for circuit-breakers for IT systems are contained in annex H.
The requirements and test methods for electromagnetic compatibility of circuit-breakers are
contained in annex J.

The requirements for circuit-breakers not fulfilling the requirements for overcurrent protection
are contained in annex L.

The requiremen
Close

RM 315.00

Document will be sent via email



 Add To Cart

LOW-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 5-5: CONTROL CIRCUIT DEVICES AND SWITCHING ELEMENTS - ELECTRICAL EMERGENCY STOP DEVICE WITH MECHANICAL LATCHING FUNCTION (IEC 60947-5-5:2005, IDT)
MS IEC 60947-5-5:2007
Status : Original
Format : PDF

This Malaysian Standard is applicable to electrical control circuit devices and switching elements which are used to provide an emergency stop signal. Such devices may be either provided with their ow ....Read more n enclosure, or installed according to the manufacturer's instructions. 
This standard does not apply to:

– emergency stop devices for non-electrical control circuit, for example hydraulic, pneumatic;
– emergency stop devices without mechanical latching function.

An emergency stop device may also be used to provide an emergency switching off function (see annex A).
Close

RM 30.00

Document will be sent via email



 Add To Cart

LOW VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 5-1: CONTROL CIRCUITS DEVICES AND SWITCHING ELEMENTS - ELECTROMECHANICAL CONTROL CIRCUIT DEVICES (IEC 60947-5-1:2 003, IDT)
MS IEC 60947-5-1:2005
Status : Original
Format : PDF

This Malaysian Standard applies to control circuit devices and switching elements intended for 

RM 135.00

Document will be sent via email



 Add To Cart

LOW - VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 4-1: CONTACTORS AND MOTOR- STARTERS - ELECTROMECHANICAL CONTACTORS AND MOTOR-STARTERS (FIRST REVISION) (IEC 60947-4-1:2002, IDT)
MS IEC 60947-4-1:2005
Status : 1st Revision
Format : PDF

This Malaysian Standard applies to the types of equipment listed in 1.1 and 1.2 whose main
 contacts are intended to be connected to circuits the rated voltage of which does not exceed
1 ....Read more 000 V a.c. or 1 500 V d.c.

Starters and/or contactors dealt with in this standard are not normally designed to interrupt short-circuit currents. Therefore, suitable short-circuit protection (see 9.3.4) shall form part of the installation but not necessarily of the contactor or the starter.

In this context, this standard gives requirements for:
– contactors associated with overload and/or short-circuit protective devices;
– starters associated with separate short-circuit protective devices and/or with separate
short-circuit and integrated overload protective devices;
– contactors or starters combined, under specified conditions, with their own short-circuit
protective devices. Such combinations, e.g. combination starters (see 3.2.7) or protected
starters (see 3.2.8) are rated as units.

Circ
Close

RM 300.00

Document will be sent via email



 Add To Cart

  • ‹
  • 1
  • 2
  • ...
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • ...
  • 588
  • 589
  • ›
©2020 All rights reserved
Department of Standards Malaysia (STANDARDS MALAYSIA). Best viewed on latest browser.