Medical electrical equipment - Part 2-40: Particular requirements for the safety of electromyographs and evoked response equipment (IEC 60601-2-40:1998, IDT)
MS IEC 60601-2-40:2007 (CONFIRMED:2013)Status : 1st Confirmation
Format : PDF
This Malaysian Standard applies to electromyographs and evoked response equipment, hereinafter referred to as equipment.
Medical electrical equipment - Part 2-37: Particular requirements for the safety of ultrasonic medical diagnostic and monitoring equipment (IEC 60601-2-37:2004, AMD. 2:2005, IDT)
MS IEC 60601-2-37:2009 (CONFIRMED:2015)Status : 1st Confirmation
Format : PDF
In this Malaysian Standard, safety requirements additional to those in the General Standard are specified for ultrasonic diagnostic equipment. This standard does not cover ultrasonic therapeutic equip ....Read more
MEDICAL ELECTRICAL EQUIPMENT - PART 2-35: PARTICULAR REQUIREMENTS FOR THE SAFETY OF BLANKETS, PADS AND MATTRESSES, INTENDED FOR HEATING IN MEDICAL USE (IEC 60601-2-35:1996, IDT)
MS IEC 60601-2-35:2007Status : Original
Format : PDF
This Malaysian Standard specifies requirements for blankets, pads, and mattresses including air-flotation mattresses and forced-air systems.
NOTE – In this Particular Standard they are refer
....Read more
Medical electrical equipment - Part 2-36: Particular requirements for the safety of equipment for extracorporeally induced lithotripsy (IEC 60601-2-36:1997, IDT)
MS IEC 60601-2-36:2007 (CONFIRMED:2013)Status : 1st Confirmation
Format : PDF
This Malaysian Standard specifies the safety requirements of equipment for extracorporeally induced lithotripsy. The applicability of this standard is limited to components directly involved in the li ....Read more
MEDICAL ELECTRICAL EQUIPMENT – PART 1-8: GENERAL REQUIREMENTS FOR SAFETY - COLLATERAL STANDARD: GENERAL REQUIREMENTS, TESTS AND GUIDANCE FOR ALARM SYSTEMS IN MEDICAL ELECTRICAL EQUIPMENT AND MEDICAL ELECTRICAL SYSTEMS (IEC 60601-1-8:2005 AND ITS AMENDMENT 1:2006, IDT)
MS IEC 60601-1-8:2007Status : Original
Format : PDF
This Malaysian Standard specifies requirements for ALARM SYSTEMS and ALARM SIGNALS in MEDICAL ELECTRICAL EQUIPMENT and MEDICAL ELECTRICAL SYSTEMS.
It also provides guidance for the application
....Read more
Luminaires - Part 2: Particular requirements - Section 4: Portable general purpose luminaires (First revision) (IEC 60598-2-4:1997, IDT)
MS IEC 60598-2-4:2003 (CONFIRMED:2015)Status : 1st Revision
Format : PDF
This Malaysian Standard specifies requirements for portable general purpose luminaires, other than handlamps, for use with tungsten filament, tubular fluorescent and other discharge lamps on supply vo ....Read more
Luminaires - Part 2-5: Particular requirements - Floodlights (First revision) (IEC 60598-2-5:1998, IDT)
MS IEC 60598-2-5:2006 (CONFIRMED:2015)Status : 1st Revision
Format : PDF
This Malaysian Standard 60598 specifies requirements for floodlights for use with tungsten filament, tubular fluorescent and other discharge lamps on supply voltages not exceeding 1,000 V.
Luminaires - Part 2-10: Particular requirements - Portable luminaires for children (First revision) (IEC 60598-2-10:2003, IDT)
MS IEC 60598-2-10:2006 (CONFIRMED:2015)Status : 1st Revision
Format : PDF
This Malaysian Standard specifies requirements for portable luminaires for children and for use with tungsten filament lamps or single capped fluorescent lamps on a supply voltage not exceeding 250 V.
Luminaires - Part 2-20: Particular requirements - Lighting chains (Second Revision) (IEC 60598-2-20:2010, IDT)
MS IEC 60598-2-20:2013Status : 2nd Revision
Format : PDF
This Malaysian Standard specifies requirements for lighting chains fitted with series- or parallel- or a combination of series/parallel-connected incandescent lamps for use either indoors or outdoors ....Read more
Luminaires - Part 2 : Particular requirements - Section 25 : Luminaires for use in clinical areas of hospitals and health care buildings (IEC 60598-2-25:1994 and its Corrigendum : 1994, IDT)
MS IEC 60598-2-25:2001 (CONFIRMED:2015)Status : 1st Confirmation
Format : PDF
This Malaysian Standard details specific requirements for luminaires for use with tungsten filament, fluorescent and other discharge lamps on supply voltages not exceeding 1 000 V for use in clinical ....Read more