Insulation coordination for equipment within low-voltage systems - Part 4: Consideration of high-frequency voltage stress (IEC 60664-4:2005, IDT)
MS IEC 60664-4:2014Status : Original
Format : PDF
This Malaysian Standard deals with basic, supplementary and reinforced insulation subjected to high-frequency voltage stress within low-voltage equipment. The dimensioning values directly apply for ba ....Read more
Insulation coordination for equipment within low-voltage systems - Part 5: Comprehensive method for determining clearances and creepage distances equal to or less than 2 mm (IEC 60664-5:2007, IDT)
MS IEC 60664-5:2014Status : Original
Format : PDF
This Malaysian Standard specifies the dimensioning of clearances and creepage distances for spacings equal to or less than 2 mm for printed wiring board and equivalent constructions, where the clearan ....Read more
Insulation coordination for equipment within low-voltage systems - Part 1: Principles, requirements and tests (IEC 60664-1:2007, IDT)
MS IEC 60664-1:2014Status : Original
Format : PDF
This Malaysian Standard deals with insulation coordination for equipment within low-voltage systems. It applies to equipment for use up to 2 000 m above sea level having a rated voltage up to a.c. 1 0 ....Read more
Insulation coordination for equipment within low-voltage systems - Part 2-1: Application guide - Explanation of the application of the MS IEC 60664 series, dimensioning examples and dielectric testing
MS 60664-2-1:2015Status : Original
Format : PDF
This Malaysian Standard, provides an application guide for manufacturers specifying dimensioning requirements for products in accordance with the MS IEC 60664 series.
The significant items for
....Read more
High pressure sodium vapour lamps - Performance specifications (Second Revision) (IEC 60662:2011, IDT)
MS IEC 60662:2013Status : 2nd Revision
Format : PDF
This Malaysian Standard specifies performance requirements for high-pressure sodium vapour lamps for general lighting purposes. It includes: - restriction to performance requirements - introduction of ....Read more
Medical electrical equipment - Part 1-2: General requirements for safety - Collateral standard electromagnetic compatibility - Requirements and test (IEC 60601-1-2:2001, IDT)
MS IEC 60601-1-2:2007 (CONFIRMED:2013)Status : 1st Confirmation
Format : PDF
This Malaysian Standard specifies requirements and tests for electromagnetic compatibility of equipment and systems and serves as the basis of electromagnetic compatibility requirements and tests in P ....Read more
Medical electrical equipment - Part 2-52: Particular requirements for the basic safety and essential performance of medical beds (IEC 60601-2-52:2009, IDT)
MS IEC 60601-2-52:2011 (CONFIRMED:2015)Status : 1st Confirmation
Format : PDF
This Malaysian Standard applies to the basic safety and essential performance of medical beds intended for adults, hereafter referred to as medical bed.
Medical electrical equipment - Part 2-47: Particular requirements for the basic safety and essential performance of ambulatory electrocardiographic systems (First revision) (IEC 60601-2-47:2012, IDT)
MS IEC 60601-2-47:2017Status : 1st Revision
Format : PDF
This Malaysian Standard applies the BASIC SAFETY and ESSENTIAL PERFORMANCE of AMBULATORY ELECTROCARDIOGRAPHIC SYSTEMS, hereafter referred to as ME SYSTEMS.
If a clause or subclause is specific
....Read more
MEDICAL ELECTRICAL EQUIPMENT – PART 2-7: PARTICULAR REQUIREMENTS FOR THE SAFETY OF HIGH-VOLTAGE GENERATORS OF DIAGNOSTIC X-RAY GENERATORS (IEC 60601-2-7:1998, IDT)
MS IEC 60601-2-7:2007Status : Withdrawn
Format : PDF
This Malaysian Standard applies to high-voltage generators of medical diagnostic x-ray generators and to their subassemblies including that are integrated with an x-ray tube assembly and of radiothera ....Read more
NOT FOR SALE
Please contact us if you are interested to purchase for reference.Medical electrical equipment - Part 2-16: Particular requirements for basic safety and essential performance of haemodialysis, haemodiafiltration and haemofiltration equipment (First revision) (IEC 60601-2-16:2012, IDT)
MS IEC 60601-2-16:2017Status : 1st Revision
Format : PDF
This Malaysian Standard applies to the basic safety and essential performance of haemodialysis, haemodiafiltration and haemofiltration equipment.
This standard does not take into consideration