Residual current operated circuit-breakers with integral overcurrent protection for household and similar uses (RCBOs) - Part 2-1: Applicability of the general rules to RCBOs functionally independent of line voltage (IEC 61009-2-1:1991, IDT)
MS IEC 61009-2-1:2003 (CONFIRMED:2015)Status : 1st Confirmation
Format : PDF
This Malaysian Standard applies to residual current operated circuit-breakers with integral overcurrent protection (RCBO’s) functionally independent of line voltage, for household and similar uses i ....Read more
Residual current operated circuit breakers with integral overcurrent protection for household and similar uses (RCBOs) Part 2-2: Applicability for the general rules to RCBOs functionally dependent of line voltage (IEC 61009-2-2:1991, IDT)
MS IEC 61009-2-2:2003 (CONFIRMED:2015)Status : 1st Confirmation
Format : PDF
This Malaysian Standard supplements or modifies the corresponding clauses in IEC 1009-1 to cover its applicability to RCBO's funtionally dependent on line voltage.
Residual current operated circuit-breakers without integral overcurrent protection for household and similar uses (RCCB’s) - Part 2-1: Applicability of the general rules to RCCB’s functionally independent of line voltage (IEC 61008-2-1:1990, IDT)
MS IEC 61008-2-1:2003 (CONFIRMED:2015)Status : 1st Confirmation
Format : PDF
This Malaysian Standard applies to RCCB's functionally independent of line voltage, for household and similar uses, not incorporating overcurrent protection, for rated voltages not exceeding 440 V a.c ....Read more
Residual current operated circuit-breakers without integral overcurrent protection for household and similar uses (RCCB’s) - Part 2-2: Applicability of the general rules to RCCB’s functionally dependent on line voltage (IEC 61008-2-2:1990, IDT)
MS IEC 61008-2-2:2003 (CONFIRMED:2015)Status : 1st Confirmation
Format : PDF
This Malaysian Standard supplements or modifies the corresponding clauses in IEC 1008-1 to cover its applicability to RCCB's functionally dependent on line voltage.
Residual current operated circuit-breakers without integral overcurrent protection for household uses (RCCBs) - Part 1: General rules (Second Revision) (IEC 61008-1:2010, IDT)
MS IEC 61008-1:2012Status : 2nd Revision
Format : PDF
This Malaysian Standard applies to residual current operated circuit-breakers functionally independent of, or functionally dependent on, line voltage, for household and similar uses, not incorporating ....Read more
Electromagnetic compatibility (EMC) - Part 4-34: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations immunity tests for equipment with mains current more than 16 A per phase (First revision) (IEC 61000-4-34:2009, MOD)
MS 61000-4-34:2014Status : 1st Revision
Format : PDF
This Malaysian Standard defines the immunity test methods and range of preferred test levels for electrical and electronic equipment connected to low-voltage power supply networks for voltage dips, sh ....Read more
Electromagnetic compatibility (EMC) - Part 3-2: Limits - Limits for harmonic current emissions (equipment input current
MS IEC 61000-3-2:2014Status : 1st Revision
Format : PDF
This Malaysian Standard deals with the limitation of harmonic currents injected into the public supply system.
It specifies limits of harmonic components of the input current which may be prod
....Read more
ELECTROMAGNETIC COMPATIBILITY (EMC) – PART 2-2: ENVIRONMENT – COMPATIBILITY LEVELS FOR LOW-FREQUENCY CONDUCTED DISTURBANCES AND SIGNALLING IN PUBLIC LOW-VOLTAGE POWER SUPPLY SYSTEMS (FIRST REVISION) (IEC 61000-2-2:2002, IDT)
MS IEC 61000-2-2:2005 (CONFIRMED:2011)Status : 1st Revision
Format : PDF
This Malaysian Standard specifies the conducted disturbances in the frequency range from 0 kHz to 9 k Hz, with an extension up to 148.5 kHz specifically for mains signalling systems. It gives compatib ....Read more
Electromagnetic compatibility (EMC) - Part 3-6: Limits - Assessment of emission limits for the connection of distorting installation to MV, HV and EHV power systems (First revision)
MS 61000-3-6:2010 (CONFIRMED:2016)Status : 1st Revision
Format : PDF
This Malaysian Standard provides guidance on principles which can be used as the basis for determining the requirements for the connection of distorting installations to mega voltage (MV), high voltag ....Read more
ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 3-11: LIMITS - LIMITATION OF VOLTAGE CHANGES, VOLTAGE FLUCTUATIONS AND FLICKER IN PUBLIC LOW-VOLTAGE SUPPLY SYSTEMS - EQUIPMENT WITH RATED CURRENT ? 75 A AND SUBJECT TO CONDITIONAL CONNECTION (IEC 61000-3-11:2000, IDT)
MS IEC 61000-3-11:2005 (CONFIRMED:2011)Status : 1st Confirmation
Format : PDF
This Malaysian Standard is concerned with the emission of voltage changes, voltage fluctuations and flicker produced by equipment and impressed on the public low-voltage supply system.
It spec
....Read more