• :  
BM ENG
  • Home
  • Service
  • International Standard
  • FAQ
  • Publish
  • signin
  •  Cart ()
Search Malaysian Standard (MS)
 Advanced Search Search




Electrical accessories - Circuit-breakers and similar equipment for household use - Auxiliary contacts units (IEC 62019:2003, IDT)
MS IEC 62019:2007 (CONFIRMED:2013)
Status : 1st Confirmation
Format : PDF

This Malaysian Standard applies to auxiliary contact units associated (or intended to be associated) with circuit-breakers for overcurrent protection, and with residual current operated circuit-breake ....Read more rs with or without integral overcurrent protection for household and similar installations, having a rated voltage not exceeding 440 V a.c. and 250 V d.c., and a rated current not exceeding 10 A. Close

RM 60.00

Document will be sent via email



 Add To Cart

Power consumption of information technology equipment - Measurement methods (IEC 62018:2003, IDT)
MS IEC 62018:2007 (CONFIRMED:2013)
Status : 1st Confirmation
Format : PDF

This Malaysian Standard applies to auxiliary contact units associated (or intended to be associated) with circuit-breakers for overcurrent protection, and with residual current operated circuit-breake ....Read more rs with or without integral overcurrent protection for household and similar installations, having a rated voltage not exceeding 440 V a.c. and 250 V d.c., and a rated current not exceeding 10 A. Close

RM 15.00

Document will be sent via email



 Add To Cart

Devices for the connection of luminaires for household and similar purposes - Part 1: General requirements (IEC 61995-1:2005, IDT)
MS IEC 61995-1:2005 (CONFIRMED:2015)
Status : 1st Confirmation
Format : PDF

This Malaysian Standard applies to devices for the connection of luminaires (DCL) intended for household and similar purposes, for the electrical connection of fixed luminaires to final circuits rated ....Read more at not more than 16 A without providing mechanical support for the luminaire. DCLs are intended for use according to their IP rating per IEC 60529. 

Outlets have an earthing contact and a rated current of 6 A, plugs are rated at 6 A, unless otherwise specified in the relevant part 2. The rated voltage is 125 V or 250 V at 50/60 Hz.

NOTE 1 This standard does not cover integrated DCL-plugs (under consideration).

This standard can also be applied to types other than those with standardised interface.
Close

RM 105.00

Document will be sent via email



 Add To Cart

Energy management system application program interface (EMS-API) - Part 301: Common information model (CIM) base (IEC 61970-301:2011, IDT)
MS IEC 61970-301:2012
Status : Original
Format : PDF

This Malaysian Standard specifies the common information model (CIM), an abstract model that represents all the major objects in an electric utility enterprise typically involved in power utility oper ....Read more ations. Close

RM 390.00

Document will be sent via email



 Add To Cart

Energy management system application program interface (EMS-API) - Part 1: Guidelines and general requirements (IEC 61970-1:2005, IDT)
MS IEC 61970-1:2011
Status : Original
Format : PDF

This Malaysian Standard specifies guidelines and general infrastructure capabilities required for the application of the EMS-API interface standards. The standard describes typical integration scenari ....Read more os where applied and the types of applications to be integrated. Close

RM 75.00

Document will be sent via email



 Add To Cart

Energy management system application program interface (EMS-API) - Part 501: Common information model resource description framework (CIM RDF) schema (IEC 61970-501:2006, IDT)
MS IEC 61970-501:2012
Status : Original
Format : PDF

This Malaysian Standard specifies a Component Interface Specification (CIS) for energy management systems application program interfaces, the format and rules for producing a machine readable form of ....Read more the Common Information Model (CIM) as specified in IEC 61970-301 standard. It describes a CIM vocabulary to support the data access facility and associated CIM semantics. Close

RM 30.00

Document will be sent via email



 Add To Cart

AUDIO, VIDEO AND AUDIOVISUAL SYSTEMS - INTERCONNECTIONS AND MATCHING VALUES - PREFERRED MATCHING VALUES OF ANALOGUE SIGNALS (IEC 61938:1996, IDT)
MS IEC 61938:2011
Status : Original
Format : PDF

This Malaysian Standard applies to electrical matching values for the interconnection of analogue signals amongst audio, video and AV system equipment.

RM 45.00

Document will be sent via email



 Add To Cart

Household electrical appliances - Method of measuring performance - Assessment of repeatability and reproducibility
MS 61923:2014
Status : Withdrawn
Format : PDF

This Malaysian Standard deals with the determination of repeatability and reporducibility of test methods used for assessing the characteristics of household electrical appliances. 

It ....Read more does not cover the development of measurement methods but deals with gathering and evaluation the information needed by a manufacturer so that values can be stated after an appliance has been subjected to an agreed test. Close

NOT FOR SALE

"Please contact us if you are interested to purchase for reference."




Household electrical hair care appliances - Methods of measuring the performance (IEC 61855:2003, MOD)
MS IEC 61855:2008 (CONFIRMED:2013)
Status : Withdrawal without replacement
Format : PDF

This Malaysian Standard applies to electrical appliances for household and similar use for drying and styling hair (including their accessories). It defines the main performance characteristics that a ....Read more re of interest to the user and specifies methods of measuring these characteristics. Close

NOT FOR SALE

"Please contact us if you are interested to purchase for reference."




Electric vehicle conductive charging system - Part 21: Electric vehicle requirements for conductive connection to an a.c./d.c. supply (IEC 61851-21:2001, IDT)
MS IEC 61851-21:2013
Status : Original
Format : PDF

This Malaysian Standard together with Part 1 gives the electric vehicle requirements for conductive connection to an a.c. or d.c. supply, for a.c. voltages according to IEC 60038 up to 690 V and for d ....Read more .c. voltages up to 1 000 V, when the electric vehicle is connected to the supply network. This standard does not cover class II vehicles. 

This standard does not cover all safety aspects related to maintenance. This standard is not applicable to trolley buses, rail vehicles, industrial trucks and vehicles designed primarily to be used off-road.
Close

RM 30.00

Document will be sent via email



 Add To Cart

  • ‹
  • 1
  • 2
  • ...
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • ...
  • 580
  • 581
  • ›
©2020 All rights reserved
Department of Standards Malaysia (STANDARDS MALAYSIA). Best viewed on latest browser.