SPECIFICATION FOR UNPLASTICISED PVC (uPVC) PIPES FOR WATER SUPPLY: PART 1: PIPES (FIRST REVISION)
MS 628: PART 1:1999
Status : 1st Revision
Format : PDF

This Malaysian Standard specifies the requirements for unplasticised PVC pipes for pressure application for use in cold water services or potable water. The pressure rating of the pipes shall be of PN ....Read more 9, PN 12 or PN 15.

The pipes shall be supplied in standard 6 m lengths with an integral socket formed on one end to provide for jointing by mechanical rubber ring or solvent weld joints. The plain end shall be chamfered to facilitate insertion during jointing and witness mark shall be put at the spigot end of the pipe.

Other lengths may be supplied as agreed upon between purchaser and supplier. The pipes shall conform to the standards as stated unless specifically pecified otherwise.

Rubber ring joints shall be manufactured for pipe sizes of 80 mm and above. For pipe sizes below 80 mm, the plain end or solvent weld joint pipes shall be manufactured.
Close

RM 60.00

Document will be sent via email



 Add To Cart

SPECIFICATION FOR UNPLASTICISED PVC(uPVC) PIPES FOR WATER SUPPLY: PART 1: PIPES (FIRST REVISION)
MS 628: PART 1:1999, AMD 2:2002
Status : Amendment 2
Format : PDF

This Malaysian Standard specifies the requirements for unplasticised PVC pipes for pressure application for use in cold water services or potable water. The pressure rating of the pipes shall be of PN ....Read more 9, PN 12 or PN 15.  Close

FREE

Document will be sent via email



Please Login to enable MS to be send via email

SPECIFICATION FOR UNPLASTICISED PVC(uPVC) PIPES FOR WATER SUPPLY: PART 1: PIPES (FIRST REVISION)
MS 628: PART 1:1999, AMD 1:2001
Status : Amendment 1
Format : PDF

This Malaysian Standard specifies the requirements for unplasticised PVC pipes for pressure application for use in cold water services or potable water. The pressure rating of the pipes shall be of PN ....Read more 9, PN 12 or PN 15.

The pipes shall be supplied in standard 6 m lengths with an integral socket formed on one end to provide for jointing by mechanical rubber ring or solvent weld joints. The plain end shall be chamfered to facilitate insertion during jointing and witness mark shall be put at the spigot end of the pipe. Other lengths may be supplied as agreed upon between purchaser and supplier. The pipes shall conform to the standards as stated unless specifically specified otherwise.

Rubber ring joints shall be manufactured for pipe sizes of 80 mm and above. For pipe sizes below 80 mm, the plain end or solvent weld joint pipes shall be manufactured.
Close

FREE

Document will be sent via email



Please Login to enable MS to be send via email

Plastics piping systems for water supply and for buried and above-ground drainage and sewerage under pressure - Unplasticized poly(vinyl chloride) (PVC-U) - Part 6: Guide for installation
MS 628-6:2015
Status : Original
Format : PDF

This Malaysian Standard set out recommended method of handling and installing unplasticised PVC pipes forwater supply. 

RM 45.00

Document will be sent via email



 Add To Cart

SPECIFICATION FOR UNPLASTICISED PVC (uPVC) PIPES FOR WATER SUPPLY: PART 2 :JOINTS AND FITTINGS FOR USE: WITH UNPLASTICISED PVC PIPES: SECTION 2.1: uPVC JOINTS AND FITTINGS
MS 628:PART 2:SECTION 2.1:1999
Status : Original
Format : PDF

This Malaysian Standard specifies the requirements for unplasticised PVC joints and fittings made principally of unplasticised polyvinyl chloride and of which one or more of the joints are intended fo ....Read more r unplasticised PVC pressure pipes complying with MS 628:Part 1.

Joints complying with this standard may be either purpose made socket formed on the pipe complying with MS 628:Part 1, or detachable couplers and other fittings, which are injection moulded.
Close

RM 45.00

Document will be sent via email



 Add To Cart

SPECIFICATION FOR UNPLASTICISED PVC(uPVC) PIPES FOR WATER SUPPLY : PART 3 : GUIDE FOR INSTALLATION
MS 628 : PART 3 : 1999
Status : Original
Format : PDF

plastics products, pipes, unplasticised PVC, water supply, handling, installation,
transporting, tests, inspection

RM 45.00

Document will be sent via email



 Add To Cart

SPECIFICATION FOR UNPLASTICISED PVC (uPVC) PIPES FOR WATER SUPPLY: PART 2: JOINTS AND FITTINGS FOR USE WITH UNPLASTICISED PVC PIPES: SECTION 2.2: SOLVENT CEMENT
MS 628:PART 2:SECTION 2.2:1999
Status : Original
Format : PDF

This Malaysian Standard specifies the requirements for solvent cement, supplied in cans or
tubes for jointing unplasticised PVC pressure pipes complying with the requirements of MS
628: Pa ....Read more rt 1 and MS 762, unplasticised PVC fittings complying with the requirements of BS
4346: Part I and unplasticised PVC pipes and fittings complying with the requirements of BS
5481.
The solvent cement is also suitable, along with solvent cement complying with the
requirements of BS 6209, for jointing products complying with the requirements of BS 4514,
BS 4576: Part I and BS 4660.
NOTE. This standard does not specify the type of can used for solvent cement, but it recommends a colour for the
cans.
Close

RM 30.00

Document will be sent via email



 Add To Cart

Plastics piping systems for water Supply and for buried and above-ground drainage and sewerage under pressure - Unplasticized poly(vinyl chloride) (PVC-U) - Part 4: Solvent cement
MS 628-4:2015
Status : Original
Format : PDF

This Malaysian Standard specifies the requirements for solvent cement, supplied in cans or tubes for jointing unplasticised PVC pressure pipes complying with the requirements of MS 628:Part 1 and MS 7 ....Read more 62, unplasticised PVC fittings complying with the requirements of BS 4346:Part 1 and unplasticised PVC pipes and fittings complying with the requirements of BS 5481.

The solvent cement is also suitable, along with solvent cement complying with the requirements of BS 6209, for jointing products complying with the requirements of BS 4514, BS 4576:Part 1 and BS 4660.

NOTE. This Malaysian Standard does not specify the type of can used for solvent cement, but it recommends a colour for the cans.
Close

RM 30.00

Document will be sent via email



 Add To Cart

Luminaires - Part 2-22: Particular requirements - Luminaires for emergency lighting (First revision) (IEC 60598-2-22:1997 and AMD. 1:2002, MOD)
MS 619-2-22:2005 (CONFIRMED:2013)
Status : 1st Revision
Format : PDF

This Malaysian Standard was developed by the Working Group on Emergency Lighting under
the authority of the Electrotechnical Industry Standards Committee.
This Malaysian Standard correspon ....Read more ds to IEC 60598-2-22:1997+A1:2002, Luminaires – Part
2-22: Particular requirements – Luminaires for emergency lighting, published by the
International Electrotechnical Commission (IEC) with the following modifications:
a) Clause 22.12.4, the ambient temperature given in the NOTE has been changed from
(20 ± 5) C to (25 ± 5) C;
b) Clause 22.16.1, after the third paragraph, the following note has been inserted:
NOTE. The designer should specify the minimum rated lumen output of the
emergency luminaires and also the high-risk task-areas;
c) Clause A.1, the NOTE shall read “Other battery types (such as nickel metal hydride,
etc) may be allowed provided they conform to their relevant safety and performance
standard and the relevant requirements of this standard”;
d) in the source text, “this International Standard” should read “this Malaysian Standard”;
e) the comma which is used as a decimal sign (if any), to read as a point; and
f) references to some International Standards are replaced by equivalent Malaysian
Standards as follows, others are retained;
Close

RM 45.00

Document will be sent via email



 Add To Cart

SWITCHES FOR HOUSEHOLD AND SIMILAR FIXED-ELECTRICAL INSTALLATIONS : PART 1 : GENERAL REQUIREMENTS (FIRST REVISION)
MS 616 : PART 1 : 1998
Status : 1st Revision
Format : PDF

This part of MS 616 applies to manually operated general purpose switches for a.c. only with a
rated voltage not exceeding 440 V and a rated current not exceeding 63 A, intended for
househ ....Read more old and similar fixed-electrical installations, either indoors or outdoors.
The rated current is limited to 16 A maximum for switches provided with screwless terminals.
NOTES.
1. An extension of the scope to switches for rated voltages higher than 440 V is under consideration
The standard also applies to boxes for switches, with the exception of mounting boxes for
flush-type switches.
2. In this standard specific requirements are given for boxes, while general requirements for boxes for ordinary*
flush type switches are given in IEC 60670.
It also applies to switches such as:
— switches incorporating pilot lights;
— electromagnetic remote control switches; (particular requirements are given in part 2);
— switches incorporating a time-delay device; (particular requirements are given in part
2);
— combinations of switches and other functions (with the exception of switches
combined with fuses);
— electronic switches (particular requirements are given in part 2);
— switches having facilities for the outlet and retention of flexible cables (see Annex B).
3. The minimum length of the flexible cable used with these switches may be governed by National Wiring Rules.
Switches complying with this standard are suitable for use at ambient temperatures not
normally exceeding 25 °C, but occasionally reaching 35°C.
4. Additional requirements for flush-type non-ordinary switches are under consideration.
5. Switches complying with this standard are suitable only for incorporation in equipment in such a way and in such
a place that it is unlikely that the surrounding ambient temperature exceeds 35°C.
In locations where special conditions prevail, as in ships, vehicles and the like and in
hazardous locations, for example where explosions are liable to occur, special constructions
may be required.
* See note 1 to 7.1.4.
This standard does not include requirements and tests for switches with protection against
ingress of solid foreign bodies. These are under consideration.
Close