• :  
BM ENG
  • Home
  • Service
  • International Standard
  • FAQ
  • Publish
  • Sign In
  •  Cart ()
Search Malaysian Standard (MS)
 Advanced Search Search




SPECIFICATION FOR FIRE HYDRANT SYSTEMS EQUIPMENT PART 3: INLET BREECHING FOR RISER INLETS
MS 1210: PART 3:1991, AMD. 1:1999
Status : Amendment 1
Format : PDF

This Malaysian Standard specifies the requirements for 2-way and 4-way inlet breechings intended for dry risers only. They are to be fitted with male instant aneous connections complying with the requ ....Read more irements of *BS 336, dlrain valves complying with the requirements of BS 5154, rating PN 16, and non-return valves. Close

FREE

Document will be sent via email



Please Login to enable MS to be send via email

SPECIFICATION FOR FIRE HYDRANT SYSTEMS EQUIPMENT PART 2: LANDING VALVES FOR DRY RISERS
MS 1210: PART 2:1991, AMD. 1:1999
Status : Amendment 1
Format : PDF

This Malaysian Standard specifies requirements for copper alloy gate valves generally complying with BS 5154, suitable for installation as landing valves on dry risers. The valves have screwed or flan ....Read more ged inlets and also delivery hose connections complying with *BS 336. The standard covers valves of nominal pressure (PN) designation 1 500 kPa and nominal inlet size DN 65 for flanged ends and 2 1/2 for screwed ends. Close

FREE

Document will be sent via email



Please Login to enable MS to be send via email

SPECIFICATION FOR FIRE HYDRANT SYSTEMS EQUIPMENT PART 1: LANDING VALVES FOR WET RISERS
MS 1210: PART 1:1991, AMD. 1:1999
Status : Amendment 1
Format : PDF

This Malaysian Standard specifies requirements for copper alloy globe valves generally complying with BS 5154 and diaphragm valves generally complying with BS 5156, both suitable for installation a sl ....Read more anding valves on wet risers. The valves have screwed or flanged inlets and also delivery hose connections complying with *Bs 336. This standard covers valves of nominal pressure (PN) designations 1 500 kPa and 2 000 kPa and nominal inlet sizes DN 40 to DN 65 for flanged ends and 11/2 and 21/2 for screwed ends.

NOTE 1. Information which the purchaser is recommended to supply to the manufacturer is given in appendix B and does not form part of the specification.
Close

FREE

Document will be sent via email



Please Login to enable MS to be send via email

Specification for fire hydrant systems equipment: Part 1: Landing valves for wet risers
MS 1210-1:1991 (CONFIRMED:2015)
Status : 1st Confirmation
Format : PDF

This Malaysian Standard specifies requirements for copper alloy globe valves generally complying with BS 5154 and diaphragm valves generally complying with BS 5156, both suitable for installation as l ....Read more anding valves on wet risers. The valves have screwed or flanged inlets and also delivery hose connections complying with *Bs 336. This standard covers valves of nominal pressure (PN) designations 1 500 kPa and 2 000 kPa and nominal inlet sizes DN 40 to DN 65 for flanged end sand 11/2 and 21/2 for screwed ends.

NOTE 1. Information which the purchaser is recommended to supply to the manufacturer is given in appendix B and does not form part of the specification.
Close

RM 45.00

Document will be sent via email



 Add To Cart

Specification for fire hydrant systems equipment - Part 2: Landing valves for dry risers
MS 1210-2:1991 (CONFIRMED:2015)
Status : 1st Confirmation
Format : PDF

This Malaysian Standard specifies requirements for copper alloy gate valves generally complying with BS 5154, suitable for installation as landing valves on dry risers. The valves have screwed or flan ....Read more ged inlets and also delivery hose connections complying with *BS 336. The standard covers valves of nominal pressure (PN) designation 1500 kPa and nominal inlet size DN 65 for flanged ends and 2 1/2 for screwed ends. Close

RM 30.00

Document will be sent via email



 Add To Cart

Specification for fire hydrant systems equipment - Part 3: Inlet breeching for riser inlets
MS 1210-3:1991 (CONFIRMED:2015)
Status : 1st Confirmation
Format : PDF

This Malaysian Standard specifies the requirements for 2-way and 4-way inlet breechings intended for dry risers only. They are to be fitted with male instantaneous connections complying with the requi ....Read more rements of *BS 336, drain valves complying with the requirements of BS 5154, rating PN 16, and non-return valves. Close

RM 15.00

Document will be sent via email



 Add To Cart

Specification for fire hydrant systems equipment - Part 4: Boxes for landing valves for dry risers
MS 1210: PART 4:1991 (CONFIRMED:2015)
Status : 1st Confirmation
Format : PDF

This Malaysian Standard specifies the requirements for boxes (including their frames, doors and glazing) suitable for enclosing landing valves for dry risers as specified in Part 2 of this standard.

RM 15.00

Document will be sent via email



 Add To Cart

Specification for fire hydrant systems equipment - Part 5: Boxes for foam inlets and dry riser inlets
MS 1210: PART 5:1991 (CONFIRMED:2015)
Status : 1st Confirmation
Format : PDF

This Malaysian Standard specifies the requirements for boxes for foam inlets or dry risers manufactured in a choice of materials to suit a particular application.

RM 15.00

Document will be sent via email



 Add To Cart

RIGID CELLULAR PLASTICS - DETERMINATION OF FLEXURAL PROPERTIES - PART 1: BASIC BENDING TEST (FIRST REVISION) (ISO 1209-1:2004, IDT)
MS ISO 1209-1:2006
Status : Withdrawn
Format : PDF

This Malaysian Standards specifies a simple method for assessing the behaviour of a bar of rigid cellular plastic under the action of three-point bending.

It may be used to determine
....Read more >
— either the load for a specified deformation;

— or the load at break.

The version of the method specified in this Malaysian Standard uses small test specimens and does not producepure bending. Hence it does not permit the calculation of the flexural strength or the apparent flexural modulus(modulus of elasticity).

The user is referred to MS ISO1209-2 for the determination of these parameters.The method is not applicable to cellular plastics in which significant crushing is observed. Numerical valuesshould be compared only when determined on materials of similar physical properties and dimensions.

The method is limited to materials of 20 mm thickness or greater.
Close

NOT FOR SALE

Please contact us if you are interested to purchase for reference.




RIGID CELLULAR PLASTICS - DETERMINATION OF FLEXURAL PROPERTIES - PART 2: DETERMINATION OF FLEXURAL STRENGTH AND APPARENT FLEXURAL MODULUS OF ELASTICITY (FIRST REVISION) (ISO 1209-2:2004, IDT)
MS ISO 1209-2:2006
Status : Withdrawn
Format : PDF

This Malaysian Standard specifies a method for determining the flexural strength and the apparent flexural modulus of elasticity of rigid cellular plastics.

NOT FOR SALE

"Please contact us if you are interested to purchase for reference."




  • ‹
  • 1
  • 2
  • ...
  • 433
  • 434
  • 435
  • 436
  • 437
  • 438
  • 439
  • ...
  • 580
  • 581
  • ›
©2020 All rights reserved
Department of Standards Malaysia (STANDARDS MALAYSIA). Best viewed on latest browser.