• :  
BM ENG
  • Home
  • Service
  • International Standard
  • FAQ
  • Publish
  • Sign In
  •  Cart ()
Search Malaysian Standard (MS)
 Advanced Search Search




Fresh french beans - Specification (Second revision)
MS 1252:2018
Status : 2nd Revision
Format : PDF

This Malaysian Standard specifies the requirements for fresh french beans (Phaseolus vulgaris L.) of the Fabaceae family to be supplied fresh to the consumer.

NOTE. Name of produce in r ....Read more eference to MS 325. Close

RM 30.00

Document will be sent via email



 Add To Cart

Guide to modular coordination in buildings – Part 3: Coordinating sizes for stairs and stair openings (Second revision)
MS 1064: PART 3:2019
Status : 2nd Revision
Format : PDF

This Malaysian Standard gives general principles for coordinating dimensions of stairs and stair openings in residential, commercial and office and institutional use, and which will fill coordinating ....Read more spaces in dimensionally coordinated buildings. Close

RM 30.00

Document will be sent via email



 Add To Cart

Water quality – Sampling – Part 20:Guidance on the use of sampling data for decision making – Compliance with thresholds and classification systems (ISO 5667-20:2008, IDT)
MS ISO 5667-20:2016 (CONFIRMED:2025)
Status : 1st Confirmation
Format : PDF

This part of ISO 5667 establishes principles, basic requirements, and illustrative methods for dealing with the use of sample data for decision making based on the assessment of the confidence that wa ....Read more ter quality:

a) meets targets and complies with thresholds;
b) has changed; and/or
c) lies in a particular grade in a classification system.

This part of ISO 5667 also specifies methods for preliminary examination of the sensitivity of decisions to error and uncertainty, although it does not cover the full range of statistical techniques.

This part of ISO 5667 provides general advice on decision making related to constraint formulation for expression of thresholds and targets and the form and scale of sampling programmes.

NOTE 1 In the water industry, “standard” is commonly used to indicate the value or limit of a parameter of interest. However, in this part of ISO 5667, the term “threshold” is used to avoid confusion with published national, regional, and International Standards.

NOTE 2 This document is framed in terms of sampling and measurement of chemical concentrations, in particular those subject to strong day-to-day temporal variations. The principles apply, however, to any item estimated by sampling which is subject to random error, including microbiological and biological data, and data subject to strong spatial variations.
Close

RM 75.00

Document will be sent via email



 Add To Cart

GUIDELINES FOR AUDITING QUALITY SYSTEMS PART 3 : MANAGEMENT OF AUDIT PROGRAMMES
MS ISO 10011 : PART 3 : 1994
Status : Original
Format : PDF

This part of IS0 10011 gives basic guidelines for managing quality systems audit programmes.

It is applicable to the establishment and maintenance of an audit programme management funct ....Read more ion when performing quality systems audits in accordance with the recommendations given in IS0 1001 l-1. Close

RM 15.00

Document will be sent via email



 Add To Cart

Insulation co-ordination - Part 4: Computational guide to insulation coordination and modelling of electrical Networks (First revision) (IEC TR 60071-4:2004, IDT) (Published by Standards Malaysia in 2022)
MS IEC TR 60071-4:2022
Status : 1st Revision
Format : PDF

This technical report gives guidance on conducting insulation co-ordination studies which propose internationally recognized recommendations

– for the numerical modelling of electrica ....Read more l systems, and
– for the implementation of deterministic and probabilistic methods adapted to the use of numerical programmes.

Its object is to give information in terms of methods, modelling and examples, allowing for the application of the approaches presented in IEC 60071-2, and for the selection of insulation levels of equipment or installations, as defined in IEC 60071-1.
Close

RM 180.00

Document will be sent via email



 Add To Cart

Switches for household and similar fixedelectrical installations – Part 1: General requirements (Second revision) (IEC 60669-1:2017, IDT) (Published by Standards Malaysia in 2022)
MS IEC 60669-1:2017
Status : 2nd Revision
Format : PDF

This part of IEC 60669 applies to manually operated general purpose functional switches, for alternating current (AC) only with a rated voltage not exceeding 440 V with a rated current not exceeding 6 ....Read more 3 A, intended for household and similar fixed electrical installations, either indoors or outdoors.

For switches provided with screwless terminals, the rated current is limited to 16 A.
Close

RM 225.00

Document will be sent via email



 Add To Cart

Portable cable reels for domestic and similar purposes - Specification (Second revision)
MS 1141:2022
Status : 2nd Revision
Format : PDF

This Malaysian Standard specifies requirement which applies to portable cable reels for alternating current (a.c.) only, having a rated voltage not exceeding 250 V, rated current not exceeding 13 A an ....Read more d provided with a non-detachable flexible cable or cord, intended for domestic and similar purposes, either indoors or outdoors.

This Malaysian Standard does not apply to cable reeling devices incorporated in appliances.

It also does not apply to portable switchgear with means for winding the cable or cord for use in building and similar sites.

Portable cable reels complying with this Malaysian Standard are suitable for use at ambient temperature normally not exceeding 35 °C, but occasionally reaching 40 °C.
Close

RM 75.00

Document will be sent via email



 Add To Cart

Specification for 15A plugs and socket-outlets for domestic and similar purposes (First revision)
MS 1577:2022
Status : 1st Revision
Format : PDF

This standard specifies the requirements for 15A rewirable plugs and switched or unswitched socket-outlets for use on a nominal supply voltage not exceeding 250 V a.c. single-phase 50 Hz. For switched ....Read more socket-outlets which contain a switch connected between the current carrying contact(s) of the socket-outlets and the relevant supply terminal(s).

In general, the provisions of this standard shall apply to plugs when wired with appropriate flexible cords or cables, and to socket-outlets installed.
Close

RM 45.00

Document will be sent via email



 Add To Cart

CODE OF PRACTICE FOR STRUCTURAL USE OF TIMBER : PART 2 : PERMISSIBLE STRESS DESIGN OF SOLID TIMBER (FIRST REVISION)
MS 544 : PART 2 : 2001
Status : Withdrawn
Format : PDF

This Part gives recommendations for the structural use of the Malaysian hardwood and softwood timber species in load bearing members. It includes recommendations on quality, grade stresses and modific ....Read more ation factors applicable to these timber when used as simple members, or as parts of built-up components, or as parts of structures incorporating other materials. It does not, and it is not intended to deal comprehensively with all aspects of timber construction. In particular it does not cover well tried and traditional methods of timber construction which have been employed successfully over a long period of time. Close

NOT FOR SALE

"Please contact us if you are interested to purchase for reference."




METHOD OF SAMPLING TEXTILE FIBRES FOR TESTING
MS 578:1979
Status : Withdrawn
Format : PDF

This Malaysian Standard specifies several methods for preparing laboratory samples of fibres and presents a limited treatment of the problem of drawing specimens for testing.

NOT FOR SALE

"Please contact us if you are interested to purchase for reference."




  • ‹
  • 1
  • 2
  • ...
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • ...
  • 580
  • 581
  • ›
©2020 All rights reserved
Department of Standards Malaysia (STANDARDS MALAYSIA). Best viewed on latest browser.